Temperature Range Fluke 62 MAX | -30 °C to 500 °C (-22 °F to 932 °F) |
---|---|
Temperature Range Fluke 62 MAX+ | -30 °C to 650 °C (-22 °F to 1202 °F) |
Accuracy Fluke 62 MAX | ±1.5 °C or ±1.5% of reading, whichever is greater, -10 °C to 0 °C: ±2.0, -30 °C to -10 °C: ±3.0 |
Accuracy Fluke 62 MAX+ | ±1.0 °C or ±1.0% of reading, whichever is greater -10 °C to 0 °C: ±2.0 -30 °C to -10 °C: ±3.0 |
Response Time (95%) Fluke 62 MAX | <500 ms (95% of reading) |
Response Time (95%) Fluke 62 MAX+ | <300 ms (95% of reading) |
Spectral Response | 8 to 14 microns |
Emissivity | 0.10 to 1.00 |
Optical Resolution Fluke 62 MAX | 10:1 (Calculated at 90% energy) |
Optical Resolution Fluke 62 MAX+ | 12:1 (calculated at 90% energy) |
Display Resolution | 0.1 °C (0.2 °F) |
---|---|
Repeatability of Readings Fluke 62 MAX | ±0.8% of reading or <±1.0 °C (2 °F), whichever is greater |
Repeatability of Readings Fluke 62 MAX+ | ±0.5% of reading or <±0.5 °C (1 °F), whichever is greater |
Power | AA battery |
Battery Life Fluke 62 MAX | 10 Hours with laser and backlight on |
Battery Life Fluke 62 MAX+ | 8 Hours with laser and backlight on |
Weight | 255 g (8.99 oz) |
Size | (175 x 85 x 75) mm (6.88 x 3.34 x 2.95) inches |
Operating Temperature | 0 °C to 50 °C (32 °F to 122 °F) |
Storage Temperature | -20 °C to 60 °C (-4 °F to 140 °F), (Without battery) |
Operating Humidity | 10 % to 90 % RH non-condensing at 30 °C (86 °F) |
---|---|
Operating Altitude | 2000 meters Above mean sea level |
Storage Altitude | 12,000 meters Above mean sea level |
IP Rating | IP 54 per IEC 60529 |
Drop Test | 3 meters |
Vibration and Shock | IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms |
EMC | EN 61326-1:2006 EN 61326-2:2006 |
Standards and Agency Approval | Compliance EN/IEC 61010-1: 2001, Laser Safety FDA and EN 60825-1 Class II |
Disclaimer
"The sale of this item may be subject
to regulation by the U.S. Food and Drug Administration and state and local
regulatory agencies. If so, do not bid on this item unless you are an
authorized purchaser. If the item is subject to FDA regulation, I will verify
your status as an authorized purchaser of this item before shipping of the
item."
Contact or Business Name, City, State, and
Phone Number.
Business Name:RVT & Associates Pvt Ltd
City:
New Delhi
State: Delhi
Phone No. +911140347793