Product: 0-480W power supply 0-5V signal control voltage
Input voltage: AC110/220V
Rated power: 480W
Product size: 21.5CM (long) *11.5CM (wide) *5CM (high)
The protection function of short-circuit / overload / overvoltage
100% full load burn-in test
Input voltage & frequency range ----------110/220VAC/47 ~ 63Hz
Start impact current ---------------20A@120VAC (cold start)
The output range of - + 100% (rated output voltage)
Overload protection -------------------105% ~ 200% (rated load), self recovery
Overvoltage protection -------------------115% ~ 135% (rated output voltage)
Short circuit protection ------------------- self recovery
Output start time - 2S@120VAC 1.0S@230VAC
Output hold time - more than 10mS@120VAC, more than 20mS@230VAC
The insulation strength ------------------- input - output: AC1500V, 1min
Input - Case: AC1500V, 1min
Output - Case: DC500V, 1min
The working environment of C - 10 to 50 DEG C; 20% ~ 90%RH (no condensation)
EMC standard - EN55022 Class B reference design;
EN61000-4-2/-3/-4/-5/-6/-11
Precautions:
When the charger is used, please unplug the battery and turn off the input power. If it is not used for a long time, please store it in a ventilated and dry environment.
To ensure safety, please perform within the line of sight when charging. If you need to leave, remove the battery to avoid unpredictable danger.
Do not mix batteries of different types, different capacities and different manufacturers.
Keep away from flammable materials when charging, pay special attention to battery temperature. If the temperature is very high, such as hot, please disconnect the power immediately to stop charging.
Do not drop wires or other conductive objects into the charger. The consequences are self-sufficient.
Do not charge if the battery leaks, rises drum, peels off, changes color, or deforms.
Do not try to charge a non-rechargeable battery.
Do not exceed the charging range specified by the battery manufacturer.
Do not modify or disassemble the charger. Turning on the machine and indicating that you have waived all warranty and technical
Terminal description and wiring method
L, N AC input terminal FG ground mark V+ DC output positive terminal
V-DC output negative terminal ADJ adjustable potentiometer Fine-tuning output DC voltage
● full voltage input
● Miniaturization
●Protection function Short circuit / overload / over voltage
●100% full load aging test
Input Voltage & Frequency Range----------110V/220VAC/47~63Hz
Start surge current ---------------20A@120VAC (cold start)
Output adjustment range --------------- ±100% (rated output voltage)
Overload protection -------------------105%~200% (rated load), self-recovery
Overvoltage protection -------------------115%~135% (rated output voltage)
Short circuit protection ------------------- self-recovery
Output start time ---------------≤2S@120VAC ≤1.0S@230VAC
Output hold time ---------------≥10mS@120VAC, ≥20mS@230VAC
Insulation strength ------------------- Input - Output: AC1500V, 1min
Input - housing: AC1500V, 1min
Output - Case: DC500V, 1min
Working environment ------------------ -10 ° C ~ 50 ° C; 20% ~ 90% RH (no condensation)