LC100A is based on the principle of LC resonance and can measure1pF-100mF capacitance and 1uH-100H inductance, capacitance resolution up to 0.01pF, inductor up to resolution 0.001uH. The instrument is especially suitable for microwave production and measurement of switching power supply transformers, filter inductors, etc.; and it has flexible online calibration to maintain measurement accuracy; instrument does not use any potentiometer adjustment, calibration parameters are completely stored in the microcontroller's FLASH, power loss will not be lost, compared to other potentiometer calibration method to be accurate and convenient. |
Item | Parameter | |
Capacitance accuracy | 1pF~1uF | 1% |
1uF~10uF | 5% | |
Measurement resolution of capacitance(C Range) | 0.01pF | |
Inductance accuracy | 1uH~100mH | 1% |
Measurement resolution of inductance(L Range) | 0.001uH | |
Largeinductance accuracy | 100mH~1H | 1% |
1H~100H | 5% | |
Measurement resolution of large inductance(Hi.L Range) | 0.001mH | |
Large capacitance accuracy | 1uF~100mF | 5% |
Measurement resolution of large capacitance(Hi.C Range) | 0.01uF | |
TestFrequency | L Range、C Range | 500kHz |
Hi.L Range | 500Hz ~50KHz | |
Measurement method of capacitance、Inductance and Large Inductance | LC Resonance | |
Measurement method of large capacitance | Charge-discharge | |
Display | 1602 LCD | |
Effective display digits | 4 digits | |
Interface to power supply | Mini USB &Φ 5.5DC Socket, 4 of AA Batteries | |
Supply Voltage | 5V | |
Product Dimensions | 150*89*29mm | |
Product Weight | 198g | |
Package Dimensions | 200*160*60mm | |
Package Weight | 280g |
1.LC-100A capacitance and inductance meter 2.Mini USB cable |