ALLEN BRADLEY 1783-BMS10CL Ser. A Stratix 5700 ethernet switch 10 port

Cat. No. 1783-BMS10CL
Ser. A
Mat.No. PN-141658

Good Condition - Fully Tested - Updated to Latest Firmware


Technical Specifications

Mechanical

Width9.14 cm
Height12.95 cm
Depth11.67 cm
Approximate weight1.25 kg
Screw torque, ground terminal, maximum0.96 Nm
Screw torque, power and alarm terminals0.23 Nm

Electrical

Number of ports 10/100 Mbps RJ458
Number of combination-ports RJ45/Mini GBIC2
Layer 2No
Layer 3No
ManageableYes
Power consumption, maximum17 W
Power dissipation17 W
Firmware typeLite
Isolation voltage (continuous), basic insulation type, DC power ports to ground, DC power ports to ethernet ports, and DC power ports to alarm ports50 V
Number of combination ports 10/100 Mbps2
Power consumption at 24V DC, 40 ˚C12.5 W
Total number of ports10
Wire size, alarm connection, solid or stranded, UL/CSA-rated style 1007 or 1569 twisted-pair copper appliance wiring material (AWM) wire0.5 mm²
Wire size, DC power connection, solid or stranded copper wire rated at 75 °C or greater0.5 mm²
Wire size, ethernet connectionRJ45 connector according to IEC 60603-7, 2 or 4-pair category 5e minimum cable according to TIA 568-B.1 or category 5 cable according to ISO/IEC 24702
Mounting methodDIN rail (top hat rail)
EthernetYes
Protection typeAlarm not rated
Alarm relay at 30V DC1 A
Alarm relay at 48V DC0.5 A
Maximum insulation, DC power connection1.2 mm
Power input at 12 - 48V DC, class 2/SELV0.5 A
Wire size, ground connection, stranded copper wire, minimum4 mm²
Wire strip length, alarm connection6.3±0.5 mm
Wire strip length, DC power connection6.3±0.5 mm
Wiring category on console and alarm ports3
Wiring category on DC power ports2
Wiring category on Ethernet ports2

Environmental

Degree of protection (IP)IP30
Housing base materialOpen-style
Nominal positionT4
Temperature, surrounding air, maximum60 °C
EFT/B immunity for IEC 61000-4-4 at 100 kHz on DC power ports±2 kV
EFT/B immunity for IEC 61000-4-4 at 100 kHz on Ethernet ports±1 kV
EFT/B immunity for IEC 61000-4-4 at 5 kHz on alarm ports±2 kV
EFT/B immunity for IEC 61000-4-4 at 5 kHz on Ethernet ports±2 kV
Emissions, CISPR11 (IEC 61000-6-4)Class A
ESD immunity, IEC 61000-4-2, air discharges15 kV
ESD immunity, IEC 61000-4-2, contact discharges8 kV
Radiated RF immunity, IEC 61000-4-3 with 1 kHz sine-wave 80% AM from 1000 - 2700 MHz10 Kg/Km
Radiated RF immunity, IEC 61000-4-3 with 200 Hz 50% pulse 100% AM at 900 MHz20 Kg/Km
Shock, non-operating, IEC 60068-2-27 (test Ea, unpackaged shock)55 g
Shock, operating, IEC 60068-2-27 (test Ea, unpackaged shock)30 g
Surge transient immunity, IEC 61000-4-5, line-earth (CM) on Ethernet ports±2 kV
Temperature, operating, IEC 60068-2-1 (test Ad, operating, cold)-40 °C
Temperature, operating, IEC 60068-2-14 (test Nb, operating, thermal shock)-40 °C
Temperature, operating, IEC 60068-2-2 (test Bd, operating, dry heat)-40 °C
Selectable start timesT4
Conducted RF immunity, IEC 61000-4-6 with 1 kHz sine-wave 80% AM from 150 kHz - 80 MHz (rms)10 V
Damped oscillatory wave immunity, IEC 61000-4-18, line-earth (CM) on power ports±2.5 kV
Damped oscillatory wave immunity, IEC 61000-4-18, line-line (DM) on power ports±1 kV
EFT/B immunity for IEC 61000-4-4 at 100 kHz on alarm ports±1 kV
EFT/B immunity for IEC 61000-4-4 at 2.5 kHz on alarm ports±4 kV
EFT/B immunity for IEC 61000-4-4 at 2.5 kHz on Ethernet ports±4 kV
EFT/B immunity for IEC 61000-4-4 at 5 kHz on DC power ports±4 kV
Radiated RF immunity, IEC 61000-4-3 with 1 kHz sine-wave 80% AM from 80 - 1000 MHz20 Kg/Km
Relative humidity, IEC 60068-2-30 (test Db, unpackaged damp heat), non-condensing5 %
Surge transient immunity, IEC 61000-4-5, line-earth (CM) on DC power ports±2 kV
Surge transient immunity, IEC 61000-4-5, line-line (DM) on DC power ports±1 kV
Temperature, non-operating, IEC 60068-2-1 (test Ab, unpackaged non-operating cold)-40 °C
Temperature, non-operating, IEC 60068-2-14 (test Na, unpackaged non-operating thermal shock)-40 °C
Temperature, non-operating, IEC 60068-2-2 (test Bb, unpackaged non-operating dry heat)-40 °C
Vibration, IEC 60068-2-6 (test Fc, operating) at 10 - 500 Hz2 g
Voltage variation IEC 61000-4-29, interruption on DC power ports10 ms