Working voltage: DC12V (normal operating voltage DC10V-16V)
Source: DC4V ~ 20V (positive trigger common power button, PNP sensors, PLC signals, etc.)
Output capability: You can control the DC or AC 220v5A within 30v5A within
Quiescent Current: 20mA,
working current: 50mA
Life: more than 10 million times;
Working temperature: -40 ~ 85'C;
Weight: about 26g
Dimensions: 64.2mm * 34.8mm * 18.5mm
Features: anti-reverse voltage input circuit, worry-free wiring. Signal input optocoupler isolation, anti-interference ability. Set the parameters of power and permanent memory. Powerful flash MCU online programming capabilities, according to user needs can contact the manufacturers to customize the functionality.
Modules and devices are powered wiring diagram:  
 
power supply modules and devices sharing wiring diagram:  
 
Features:
S1: power on, press S1 2 seconds to enter mode selection menu, press S1, choose P-1 ~ P-4 mode.
S2: OK / Shift key: Press to adjust the position of the LED is blinking, which LED is blinking, S3 to adjust the value of digital tube flicker. Until you press S2, the digital is no longer flashing.
S3: digital display flashes, S3 adjustment digits from 0-9 successively changed. Normal digital tube display, S3 to adjust the position of the decimal point, the decimal point in bits 0-999 minutes; in 10 bit from 0 to 99.9 seconds; no decimal point indicates 0-999 seconds.
Model Description:
P-1: triggering signal is received, the relay is turned on, the timer expires, the relay off.
A1: During the delay trigger again invalid
A2: During re-timing delay trigger again
A3: Delay trigger again during termination timing relay reset
P-2: triggering signal is received, X start time, the end of counting relay, Y start time, the end of counting the relay off
P-3: Cycle Switch Mode
A1: After power relay is turned on, the end of the timing off, an infinite loop.
          A2: After power relay is off, the timing turned end, an infinite loop.
Instructions:
P-1 mode: Long press S1 2 seconds to enter mode selection menu, press S1, select P-1, press S2 OK; automatically jump to the menu to select the function after pressing S1 (A1 A2 A3 optional), press S2 OK; automatically jump to set the time, press S3 to adjust the position of the decimal point, automatically jump press S2 OK LED is blinking, press S3 to adjust the flashing digits from 0-9 successively changed, press S2 to determine the order of operation until the blinking stops, set fixed end.
P-2 mode: Long press S1 2 seconds to enter mode selection menu, press S1, select P-2, press S2 OK; automatically jump to the [closing time] settings, press S3 to adjust the position of the decimal point, automatically jump press S2 OK turn LED is blinking, press S3 to adjust the flashing digits from 0-9 successively changed, press S2 to determine the order of operation until the flashing stops, the green light; the time to jump to the [open] setting, press S3 to adjust the position of the decimal point, press S2 OK after automatically jump, LED is blinking, press S3 to adjust the flashing digits from 0-9 successively changed, press S2 to determine the order of operation until the flashing stops, setting the end.
P-3 mode: Long press S1 2 seconds to enter mode selection menu, press S1, select P-3, press S2 OK; automatically jump to the menu to select the function after pressing S1 (A1 A2 optional), press OK S2 ; automatically jump to the [closing time] settings, press S3 to adjust the position of the decimal point, automatically jump press S2 OK LED is blinking, press S3 to adjust the flashing digits from 0-9 successively changed, press S2 to determine the order of operations until the blinking stops , green light; the time to jump to the [open] setting, press S3 to adjust the position of the decimal point, automatically jump press S2 OK LED is blinking, press S3 to adjust the flashing digits from 0-9 successively changed, press S2 to determine the order of operations until the flashing stops, setting the end.
P-4 mode: Long press S1 2 seconds to enter mode selection menu, press S1, select P-4, press S2 OK; automatically jump to set the time, press S3 to adjust the position of the decimal point, and press S2 automatically jump OK, Digital flashes, press S3 to adjust the flashing digits from 0-9 successively changed, press S2 to determine the order of operation until the flashing stops, setting the end.

Mian business 

We sell high quality items at the best prices.

All items will be tested before shipping. We aim for long term to keep your business. We mainly sell ICs, electronic components,
electronic modules and PCB boards etc.

We can also help our customers to find other items that we do not list in our store. Please contact us if you need something,
we can always provide the best price.



Payment & Return Policy

   

    We accept Paypal.
    - If you haven't received the product within 2 months (60 days), please contact with us,we promise to refund
   100% of your money.
    - We ensure our products work normally before post. If the product is broken after arrival, you should
    take a photo to show the broken product. We promise to refund 100% of your money.


 

Feedback 

We appreciate positive feedback.

We always try our best to give the best service every customer.

 If you have any questions,

PLEASE DON’T HESITATE TO CONTACT US IMMEDIATELY,

We are always here to help.

Shipping Policy

      

         All items will be shipped within 1~2 business days after payment.

         By China post, Singapore post or HK post. 
         
If you order more than $25, we provide a free tracking number,

          if your order is less than $25 then customers can optionally pay $2

          for a tracking number.


 

  •  Ship to address provided by  ebay if no special notes from  buyer .
  • Delivery Time: Normally, It Takes About 10-30 Business Days to  Arrival for most Countries.

*5-14 days to USA.
*10-25 days to Australia / Canada.
*14-30 days to major cities in Europe .
*4 - 8 weeks to Italy , Brazil ,Russia.

However, it may delay due to industrial strike action, severe  weather, custom reasons or peak seasons, 

such as Christmas/New Year  Holidays.


On 17-Jun-15 at 08:56:23 BST, seller added the following information:


On 28-Nov-15 at 06:12:02 GMT, seller added the following information:


Powered by eBay Turbo Lister
{{paymentterms}}
{{shippingterms}}
{{salesterms}}
{{aboutus}}
{{contactus}}
{{paymentterms}}
{{shippingterms}}
{{salesterms}}
{{aboutus}}
{{contactus}}
PushAuction

DataCaciques