1200W Micro-inverter solar grid system (Power line
communications)
IP65
waterproof streamline design, Can effectively prevent rainwater on the surface
erosion, Built-in high-performance Maximum Power Point Tracking(MPPT)Function,Better
able to track changes in the solar luminosity and control different output
power, Effectively capture and collect sunlight. AC electric power transmission
using the reverse transmission technology, Is one of our patented technology, The
inverter output power can provide load priority use, Extra electricity to the
grid, Efficient use of the inverter to the power emitted, Electricity
transmission rate of up to 99%.
Communication
using two modes,
Between the inverter and Collector Using
power line carrier communication signals, Collector with a PC or
other devices to communicate Using RS232 serial port/ WIFI
wireless communication.
Intelligent monitoring systems, The
inverter can collect real-time data, Inverter can be
controlled startup / shutdown / power regulation.
|
Features:
l High
performance maximum power point tracking (MPPT)
l Reverse
power transmission
l Intelligent
monitoring management
l Input
/output is fully isolated to protect the electrical safety
l Multiple
parallel stacking
l Digital
control system
l Simplify
maintenance (user serviceable)
l Operation
and maintenance costs low
l Flexible
installation
1200W Parameters
Input
Data |
1200-120VAC/230VAC |
|||
Recommended input power |
1200Watt |
|||
Recommend the use of PV modules |
4*300W/Vmp>34V/Voc<50V |
|||
Maximum input DC voltage |
50V |
|||
Peak power tracking voltage |
25-40V |
|||
Operating Voltage Range |
17-50V |
|||
Min / Max start voltage |
22-50V |
|||
Maximum DC short current |
|
|||
Maximum Input Current |
|
|||
Output
Data |
@120VAC |
@230VAC |
||
Peak power output |
1200Watt |
1200Watt |
||
Rated output power |
1150Watt |
1150Watt |
||
Rated output current |
|
|
||
Rated voltage range |
80-160VAC |
180-260VAC |
||
Rated frequency range |
57-62.5Hz |
47-52.5Hz |
||
Power factor |
>98% |
>98% |
||
Maximum units per branch circuit |
3PCS(Single-phase) |
5PCS(Single-phase) |
||
Output
Efficiency |
@120VAC |
@230VAC |
||
Static MPPT efficiency |
99.5% |
99.5% |
||
Maximum output efficiency |
92% |
92% |
||
Night time power consumption |
<50mW Max |
<70mW Max |
||
THD |
<5% |
<5% |
||
Exterior |
||||
Ambient temperature |
|
|||
Operating temperature range
(inverter inside) |
|
|||
Dimensions (WxHxD) |
|
|||
Weight |
2.85kg |
|||
Waterproof Rating |
IP65 |
|||
Cooling |
Self-cooling |
|||
Feature |
||||
Communication Mode |
Power Line |
|||
Power transmission mode |
Reverse transfer, load priority |
|||
Monitoring System |
Lifetime free |
|||
Electromagnetic
compatibility |
EN50081.part1
EN50082.part1 |
|||
Grid
disturbance |
EN6 |
|||
Grid
detection |
DIN
VDE 1026 UL1741 |
|||
Certificate |
CEC,CE
National patent technology |
|||
* Note:
The monitoring software can monitor multiple threads simultaneously 6 PCS power
line acquisition
simultaneously monitor 600 inverters.
1)
Each
Power Line Modem monitoring 100 inverters
2)
onitoring
system simultaneously collect real-time data from 6 power line Modem by 6 threads