Description:
1. 4-way multi-function relay control module adopts industrial-grade high-quality components, and is designed and processed with meticulous design, stable performance, simple operation, and can be widely used in various power control applications.
2. The module presets up to 20 kinds of functions, uses 8-36V wide voltage power supply design, and adds the linkage function of each channel, users can freely combine many new applications, such as sequential linkage, cycle linkage, water lights and so on.
Feature:
1. Each channel linkage function.
2. With 4 channels of input and output control, each channel can be set to 20 kinds of functions to meet more application requirements.
3. DC 8V-36V wide voltage input, with power supply anti-reverse function, will not damage the module because of the wrong power.
4. With power indicator, relay pull-in indicator.
5. At least 1 second timing function can be set, timing accuracy is better than 1%.
6. Increase automatic power saving function.
7. All setting options can be automatically saved, setting content is not lost when power off.
8. Trigger input supports user selection, high or low pulse trigger.
Specification:
Operating voltage: Recommended DC 8V-36V (limit working voltage DC 6V-45V)
Rated power: static power (when relay is not pulled) is less than 0.1W
Dynamic power (when the relays are all pulled in) is less than 1.5W
Working temperature: Recommended -20 °C -60 °C (limit working temperature range -30 °C -70 °C)
Load capacity: Relay normally open port Load capacity: DC 0-30V/10A, AC 0-250V/10A
Relay normally closed port load capacity: DC 0-28V/10A, AC 0-125V/10A
Module Interface:
Module voltage/signal input: 8-wire interface, all interfaces have terminals for user convenience.
1. VIN: positive DC power supply.
2. GND: DC power negative.
3. OFF: power control terminal (power off when the high level).
4. COM: Common end of optical isolation signal input.
5. IN1-IN4: input signal detection interface.
Note:
1. The input signal detection interface can be either active-high or active-low. The user can select via COM port. If COM is connected to H, IN1-IN4 is active high, if COM is connected to L, IN1 -IN4 is active low!
2. Trigger voltage (COM, IN1-IN4 port voltage): Do not exceed 5V at high level, and do not exceed 0.8V at low level.
3. Relay load output: 12-wire interface, all interfaces have terminal blocks.
Module function:
The user can select one of the following 20 functions by pressing the key and display, and can freely combine the linkage modes between the various paths. The function parameters can be set and saved. Two time parameters T1 and T2 can be set. The time parameter is 1 Adjustable from seconds to 255 hours with a maximum accuracy of better than 0.01 seconds.
When high level trigger is selected:
Function 1: Power-on delay pull-in: After delaying T1 time from power-on, the relay pulls in, and at any time, a high-level pulse signal is sent to the X interface. This function is reset and restarts operation.
Function 2: The power-on delay is disconnected: when the power is on, the relay pulls in, and after pulling T1 time, the relay is disconnected, and a high-level pulse signal is given to the X1 interface at any time. This function is reset and restarts operation;
Function 3: Regular pull-in and then break-off: When the power is turned on, the relay is turned off. After the off-time T1 is reached, the relay pulls in. After the pull-in time T2 is reached, the relay is off. The X interface is given a high-level pulse signal at any time. Function reset and restart operation;
Function 4: Timing off and then on: When the power is on, the relay pulls in. When the pull-in time T1 arrives, the relay turns off. When the off-time T2 arrives, the relay pulls in. At any time, it gives the X interface a high-level pulse signal. Function reset and restart operation;
Function 5: Infinite loop mode 1: When the power is turned on, the relay is turned off. After the off time T1 arrives, the relay pulls in. After the pull-in time T2 is reached, the relay is off, and then the above state is repeated. The X interface is high at any time. Pulse signal, this function resets and restarts operation;
Function 6: Infinite loop mode 2: When the power is turned on, the relay immediately pulls in. After the pickup time T1 arrives, the relay turns off. After the off time T2 arrives, the relay pulls in and then repeats the above state. Any time, the X interface is high. Flat pulse signal, this function resets and restarts operation;
Function 7: Limited Cycle Mode 1: When the power is turned on, the relay opens. After the off time T1 arrives, the relay pulls in. After the pull-in time T2 arrives, the relay turns off, and then repeats the action more than NX times. The cycle number NX is in the range of 1 - 9999. Adjustable between times, any time to a high level pulse signal to the X interface, this function reset and restart the operation;
Function 8: Limited Cycle Mode 2: When the power is on, the relay pulls in and the relay turns off after the pull-in time T1 arrives; the relay pulls up after the turn-off time T2 arrives, and then repeats the action more than NX times. The cycle number NX is in the range of 1-9999. Adjustable between times, any time to a high level pulse signal to the X interface, this function reset and restart the operation;
Function 9: Self-locking relay mode: A high-level pulse signal is sent to the relay X interface, the relay pulls in, and then a high-level pulse signal relay is turned off.
Function 10: Level-triggered relay mode (including delay disconnection function): When the power is turned on, the relay is disconnected, and a high-level signal is sent to the X interface, and the relay immediately pulls in. After the X port signal disappears, the relay still pulls in. After the pull-in time T1 is reached, the relay opens. Note: In this function, if T1 is set to 0 seconds, it will become: X port has high level signal relay to pull in, and if there is no signal, it will be disconnected immediately.
Function 11: After the trigger, the timer is closed: when the power is turned on, the relay is disconnected, and a high-level pulse signal is sent to the X interface. The time relay T1 is pulled and the X interface is repeated to a high level pulse signal, and the function is repeated more than once;
Function 12: After the trigger, the timer is disconnected: when the power is turned on, the relay is disconnected, and a high-level pulse signal is sent to the X interface. The relay pulls in and the relay T1 is disconnected, and repeats the X interface with a high-level pulse signal. More than one function;
Function 13: After the trigger, the timer is switched on and off again: when the power is turned on, the relay is disconnected, and a high level pulse signal is sent to the X interface. After the disconnection time T1 arrives, the relay pulls in; after the pickup time T2 is reached, the relay is disconnected and repeated. Give the X interface a high level pulse signal and repeat more than one function;
Function 14: After the trigger, the timer is disconnected and then the pull-in is switched on: when the power is turned on, the relay is disconnected, and a high-level pulse signal is sent to the X interface. The relay pulls in. After the pull-in time T1 arrives, the relay is opened; after the cut-off time T2 arrives, the relay Suction, repeated to the X interface a high pulse signal, repeat more than one function;
Function 15: Infinite loop after triggering mode 1: The relay is disconnected during power-on, and a high-level pulse signal is sent to the X interface. After the delay time T1 arrives, the relay pulls in; after the pull-in time T2 arrives, the relay is disconnected and then repeats The above action, repeated to the X interface a high pulse signal, you can restart the above function;
Function 16: After the trigger, the infinite loop mode 2: The relay is disconnected when the power is turned on, and a high-level pulse signal is sent to the X interface. The relay pulls in, and the relay opens after the pull-in time T1 arrives; the relay pulls in after the cut-off time T2 arrives. , and then repeat the above action, repeated to the X interface a high pulse signal, you can restart the above function;
Function 17: After triggering, the finite-cycle timing mode 1: When the power is turned on, the relay is disconnected, and a high-level pulse signal is sent to the X interface. After the off-time T1 arrives, the relay pulls in; after the pull-in time T2 arrives, the relay is off, and then Repeat the action more than NX times. The cycle number NX is adjustable between 1-9999 times. Repeatedly giving the X interface a high-level pulse signal can restart the above function;
Function 18: After the triggering, the finite-cycle timing mode 2: When the power is turned on, the relay is disconnected, and a high-level pulse signal is sent to the X interface, the relay immediately pulls in, and the relay turns off after the pull-in time T1 arrives; the relay turns off after the time T2 arrives. Pull, then repeat NX more actions, the number of cycles NX adjustable between 1-9999 times, repeated to the X interface a high pulse signal, you can restart the above function;
Function 19: Conditional cycle mode 1: When the power is turned on, the relay is disconnected and a high level signal is sent to the X interface. After the delay time T1 arrives, the relay pulls in; after the pull-in time T2 arrives, the relay turns off, as long as the X port is high. Does not disappear, the module will repeat the above action, if the X interface high signal disappears, the relay immediately disconnected, function reset;
Function 20: Conditional cycle mode 2: When the power is turned off, the relay outputs a high-level signal to the X interface, and the relay pulls in. After the pull-in time T1 arrives, the relay turns off; when the off time T2 arrives, the relay pulls in, as long as X. If the high level of the port does not disappear, the module will repeat the above action. If the high signal of the X interface disappears, the relay is immediately disconnected and the function is reset;
Included:
1 X 4 Way Multifunction Cycle Delay Timer Relay Module
We only ship to Ebay Address,Please Make sure it's 100% right.
when your payment is clear.
Country |
DELIVERY TIME |
|||||
Shipping time will be longer than below period due to the flight and holiday |
||||||
WORKING DAYS |
5-7 |
8-10 |
12-14 |
15-19 |
20-22 |
|
WORKINGDAYS+SATURDAY+SUNDAY |
5-9 |
8-15 |
16-20 |
21-25 |
26-30 |
|
Australia |
Rate(time arrived) |
21.4% |
52.1% |
14.3% |
7.2% |
4% |
United States |
Rate(time arrived) |
5.2% |
80% |
14.3% |
0.5% |
|
United Kingdom |
Rate(time arrived) |
9.9% |
63.2% |
19.1% |
3.4% |
4.4% |
Germany |
Rate(time arrived) |
11.1% |
22.2% |
30.3% |
20.9% |
15.5% |
Canada |
Rate(time arrived) |
2% |
45.1% |
31.4% |
17.6% |
4% |
Italy,Russia |
Rate(time arrived) |
2.5% |
10.2 |
18.2% |
17.3% |
31.3% |
Spain |
Rate(time arrived) |
3.5% |
25% |
47.9% |
12.9% |
10.7% |
Brazil , most of the south America country |
Rate(time arrived) |
Most package will need 4-8 weeks |
||||
Other country |
Rate(time arrived) |
0.5% |
8.6% |
15.0% |
43.8% |
28.1% |
Here you can find items with high quality and best price .
\all items will be tested before shipped. Good quality is the basic of business. we seek for long term .We mainly selling ICs, electronic component ,
electronic modules.PCB board etc
ICs,
ICs business is our basic business. We specialized in ICs for nearly 10 years.
Located in HQB electronic market in SHENZHEN China. We stock ICs ourselves. We are not trader. So you can always find a good price here ,
For Big quantity, please send message to us to get a better price .
Electronic module.
We product modules . work with many big factory directly . they are all big factory , they have QC department, have strict control on quality ,
unlike the many small factory always selling modules without tested. So we can make sure every module you buy here is with high quality. Of course.
Best price too . For Big quantity, please send message to us to get a better price .
We also accept OEM or ODM order . if you need to design an module. Please feel free to contact us .
PCB boards
We product module . so work with big PCB factory .
Quality is really good , and price also low price,
Please don’t hesitate to send us message for a quote, then you will find we are the right business partner you are
looking for . .