Feature:
Installation:
1. Clean the compressed air system before installation
2. Pay attention to the direction of the arrow of the valve body; do not use the hose that does not affect the air outlet.
3. The power supply voltage must be the same as the drain valve voltage; when using DC, the positive pole must be connected to the connector "1"
4. The factory has been connected to the cable drain valve, light fire line L, blue is zero line N, yellow and green are safe ground GND
5. Always tighten the long screws on the junction box to prevent water scorching
Note:
When installing the electronic drain valve, please ensure that:
1. Compressed air has been emptied (zero pressure)
2. The power is cut off
Timer settings:
The left knob sets the discharge time, and the right knob sets the interval time; the first discharge time is 2s, the interval time is 20min, and then the specification needs to be further adjusted.
Specification:
Product Name: Timing Drain Valve
Type: A: split-body type , B: one-body type
Voltage: AC220V,DC24V,AC110V,DC12V
Material: ABS plastic + brass valve body
Voltage range: 10%
Time interval (OFF): 0.5--45 minutes (adjustable)
Discharge time (ON): 0.5 - 10 seconds (adjustable)
Manual test button: yes (mini switch)
Current consumption: up to 4mA
Ambient temperature: -40 to 60 degrees Celsius
Protection level: IP65
Housing material: flame retardant ABS plastic
Electrical connection: DIN43650A
Indicator light: LED indicating power on/off
Type: two-way direct acting valve
Flow aperture: 5 mm
Insulation class: H
Input / output port size: 1/2 inch
Maximum working pressure: 1.6Mpa
Maximum temperature: 90 degrees Celsius
Color: Gold
Note: The plug is built in and you can unscrew the screw.
Package includes:
1 * Electric Timer Auto Water Valve