Citizen Electronic Blood Pressure Monitor Wrist White CH650F

Description

・ Medical device classification: Specified management medical device
・ Medical device certification (approval) number: 221ADBZX00090000
・ Size: Width 65 x Height 74 x Depth 29 mm (excluding wrist cuff)
・ Body weight: Approximately 103g (excluding batteries)
・ Power supply: DC3V, 2 AAA alkaline batteries
・ Accessories: Instruction manual (with warranty), 2 AAA alkaline batteries (for monitor), storage case

When the inside of the cuff is gradually pressurized, a pulsating phenomenon that synchronizes with the heartbeat appears in the pressure inside the cuff. The onset of this pulsation is small, it increases as the pressure rises, and after showing the maximum amplitude, it becomes a mountain-shaped pattern that decreases again. The oscillometric sphygmomanometer analyzes the amplitude waveform information of this pulsation with a microcomputer to determine the systolic blood pressure value and diastolic blood pressure value.
General name: Automatic electronic sphygmomanometer (classification: 167)
Product name: Citizen Electronic Blood Pressure Monitor CH-650F
Contraindications / Prohibitions:
・ If you want to measure by yourself, measure and get a diagnosis under the guidance of your doctor. Follow your doctor's instructions when taking the drug. Follow your doctor's instructions when taking the drug. Do not self-judgment or treat the measurement results.
・ Do not wrap a wrist cuff around an unhealed wrist such as a wound. [May worsen unhealed areas]
・ Do not wrap a wrist cuff around the wrist that is undergoing intravenous drip injection or blood transfusion during treatment.
・ If you have a severe blood circulation disorder on your wrist or arm, consult a doctor before use. [May cause you to feel unwell]
・ Measurement may not be possible for those with low blood flow at the measurement site, those with weak vascular veins, and those with a high frequency of arrhythmia. The decision depends on the doctor. Always consult your doctor before use.
・ Do not continue or use with other medical devices and instruments. [May cause injury or accident]
・ Do not use near flammable gas such as anesthetic gas in the hospital. [May be ignited]
・ Do not use in high-concentration oxygen such as in a high-pressure oxygen room or oxygen tent in a hospital. [May ignite]
・ Do not use in medical institutions, public places, etc. where an unspecified number of subjects are targeted. If you have a pacemaker, please consult your doctor.

Item specifications, etc .:
Error in blood pressure measurement by clinical performance test
Average error from auscultation: within ± 5 mmHg
Standard deviation of error: within 8mmHg
In-cuff pressure display error: within ± 3 mmHg
Rapid exhaust: 10 seconds or less
Measurement method: oscillometric method
Pressure measurement range in the cuff: 0 to 280 mmHg (Unit: 1 mmHg)
Wrist circumference: 13.5 to 21.5 cm (measurable wrist circumference range)
Specifications:
(1) Do not use for any purpose other than blood pressure measurement. Do not disassemble, repair or modify. [May cause fire, malfunction or accident]
(2) Keep away from devices that generate electromagnetic waves, such as mobile phones. [May malfunction]
(3) Do not use for people who cannot express their intentions or infants.
(4) You may measure by yourself under the guidance of a doctor. Follow your doctor's instructions and measure correctly.
(5) Continuous measurement of blood pressure may cause congestion and swelling. Be sure to leave an interval (1 minute or more) before measuring.
(6) If a mark appears on the display or nothing is displayed when you press the [Measure / Stop] switch, replace 4 batteries with new batteries at the same time.
(7) If the air does not escape even after pressing the [Measure / Stop] switch, remove the wrist cuff.
(8) If you find a malfunction, stop using it immediately, do not disassemble it, and contact your dealer or Citizen System Customer Service Office (0120-88-6295).
Manufacturer and Manufacturer Information:
Manufacturer: Citizen Systems Co., Ltd.
6-1-12 Tanashicho, Nishitokyo-shi, Tokyo
Phone: 0120-88-6295
Effect / Efficacy:
Systolic and diastolic blood pressure are measured non-invasively for health management. There is no support for the newborn mode defined in JIS T 1115: 2005 Section 3 s).

how to use

When the inside of the cuff is gradually pressurized, a pulsating phenomenon that synchronizes with the heartbeat appears in the pressure inside the cuff. The onset of this pulsation is small, it increases as the pressure rises, and after showing the maximum amplitude, it becomes a mountain-shaped pattern that decreases again. The oscillometric sphygmomanometer analyzes the amplitude waveform information of this pulsation with a microcomputer to determine the systolic blood pressure value and diastolic blood pressure value.
General name: Automatic electronic sphygmomanometer (classification: 167)
Product name: Citizen Electronic Blood Pressure Monitor CH-650F
Contraindications / Prohibitions:
・ If you want to measure by yourself, measure and get a diagnosis under the guidance of your doctor. Follow your doctor's instructions when taking the drug. Follow your doctor's instructions when taking the drug. Do not self-judgment or treat the measurement results.
・ Do not wrap a wrist cuff around an unhealed wrist such as a wound. [May worsen unhealed areas]
・ Do not wrap a wrist cuff around the wrist that is undergoing intravenous drip injection or blood transfusion during treatment.
・ If you have a severe blood circulation disorder on your wrist or arm, consult a doctor before use. [May cause you to feel unwell]
・ Measurement may not be possible for those with low blood flow at the measurement site, those with weak vascular veins, and those with a high frequency of arrhythmia. The decision depends on the doctor. Always consult your doctor before use.
・ Do not continue or use with other medical devices and instruments. [May cause injury or accident]
・ Do not use near flammable gas such as anesthetic gas in the hospital. [May be ignited]
・ Do not use in high-concentration oxygen such as in a high-pressure oxygen room or oxygen tent in a hospital. [May ignite]
・ Do not use in medical institutions, public places, etc. where an unspecified number of subjects are targeted. If you have a pacemaker, please consult your doctor.

Item specifications, etc .:
Error in blood pressure measurement by clinical performance test
Average error from auscultation: within ± 5 mmHg
Standard deviation of error: within 8mmHg
In-cuff pressure display error: within ± 3 mmHg
Rapid exhaust: 10 seconds or less
Measurement method: oscillometric method
Pressure measurement range in the cuff: 0 to 280 mmHg (Unit: 1 mmHg)
Wrist circumference: 13.5 to 21.5 cm (measurable wrist circumference range)
Specifications:
(1) Do not use for any purpose other than blood pressure measurement. Do not disassemble, repair or modify. [May cause fire, malfunction or accident]
(2) Keep away from devices that generate electromagnetic waves, such as mobile phones. [May malfunction]
(3) Do not use for people who cannot express their intentions or infants.
(4) You may measure by yourself under the guidance of a doctor. Follow your doctor's instructions and measure correctly.
(5) Continuous measurement of blood pressure may cause congestion and swelling. Be sure to leave an interval (1 minute or more) before measuring.
(6) If a mark appears on the display or nothing is displayed when you press the [Measure / Stop] switch, replace 4 batteries with new batteries at the same time.
(7) If the air does not escape even after pressing the [Measure / Stop] switch, remove the wrist cuff.
(8) If you find a malfunction, stop using it immediately, do not disassemble it, and contact your dealer or Citizen System Customer Service Office (0120-88-6295).