Höffman Turbocharger BMW 335 535 635 d X3 X5 X6 3.0 sd 35 - 53261015183 Reman
 
   
     
             
   
 
 
   
     
    
universal plug-in relay
 - Zelio RUM - 2 C/O - 12 V DC - 10 A
 RUMC23JD
      
Item Description
New Product, box opened for inspection and photos - we not using stock photos- what you see is what you buying

Main
range of product
Harmony Relay
series name
Universal
product or component type
Plug-in relay
device short name
RUM
contacts type and composition
2 C/O
[Uc] control circuit voltage
12 V DC
[Ithe] conventional enclosed thermal current
10 A at -40…55 °C
status LED
With
control type
Without lockable test button
utilisation coefficient
20 %
Complementary
shape of pin
Cylindrical
[Ui] rated insulation voltage
250 V conforming to IEC
300 V conforming to CSA
300 V conforming to UL
[Uimp] rated impulse withstand voltage
4 kV (1.2/50 µs)
contacts material
AgNi
[Ie] rated operational current
10 A at 277 V AC conforming to UL
10 A at 30 V DC conforming to UL
10 A at 30 V DC conforming to CSA
5 A at 250 V AC (NC) conforming to IEC
5 A at 28 V DC (NC) conforming to IEC
10 A at 250 V AC (NO) conforming to IEC
10 A at 28 V DC (NO) conforming to IEC
10 A at 277 V AC conforming to CSA
maximum switching voltage
250 V conforming to IEC
Resistive rated load
10 A at 250 V AC
10 A at 28 V DC
maximum switching capacity
2500 VA/280 W
minimum switching capacity
170 mW at 10 mA, 17 V
operating rate
<= 18000 cycles/hour no-load
<= 1200 cycles/hour under load
mechanical durability
5000000 cycles
electrical durability
100000 cycles for resistive load
Average coil consumption in W
1.4 W
drop-out voltage threshold
>= 0.1 Uc DC
Operate time
20 ms at nominal voltage
Release time
20 ms at nominal voltage
Average coil resistance
120 Ohm at 20 °C +/- 15 %
rated operational voltage limits
9.6...13.2 V DC
protection category
RT I
test levels
Level A group mounting
safety reliability data
B10d = 100000
operating position
Any position
net weight
0.086 kg
device presentation
Complete product
Environment
dielectric strength
1500 V AC between contacts with micro disconnection
2500 V AC between coil and contact with reinforced
2000 V AC between poles with basic
product certifications
UL
EAC
CSA
standards
CSA C22.2 No 14
EN/IEC 61810-1
UL 508
ambient air temperature for storage
-40…85 °C
ambient air temperature for operation
-40…55 °C
vibration resistance
3 gn, amplitude = +/- 1 mm (f = 10…150 Hz)5 cycles in operation
4 gn, amplitude = +/- 1 mm (f = 10…150 Hz)5 cycles not operating
IP degree of protection
IP40
shock resistance
10 gn (duration = 11 ms) for in operation conforming to EN/IEC 60068-2-27
10 gn (duration = 11 ms) for not operating conforming to EN/IEC 60068-2-27 