APC AP8841 Rack Power Distribution Unit , Input: 200/240V, 50/60Hz, 24A. Output: 200/240V, 16A Per Bank, 24A Total.

Unit is in excellent working condition.

Overview
PresentationAPC Metered Rack PDUs distribute reliable rack power distribution via a single input with multiple output receptacles. Real-time remote monitoring and user-defined alarms help prevent potential circuit overloads that can cause accidental power loss to critical equipment. Easily access, configure, and manage this metered PDU from remote locations. A network management interface provides standards-based management via Web, SNMP, and Command Line Interface. This Metered PDU from APC provides (36) IEC 60320 C13 and (6) IEC 60320 C19 outlets to supply power to rack equipment. Locking IEC receptacles enable locking power cord compatibility to reduce the probability of accidentally disconnecting cords and dropping loads. Volts, amps, real power (kW), and energy (kWh) data is provided to support energy management. An embedded log memory to reports historic metered data. Display details current, power, and voltage measurements and offers local user access. An environmental monitoring port for external temperature/humidity monitoring is available (sensor sold separately model AP9335T or AP9335TH). Easily mount this vertical PDU in racks or enclosures. It occupies zero U of valuable rack space, which allows space for more equipment in the rack. This vertical PDU does not require additional tools to mount into APC NetShelter Enclosures. Enables a quick recovery from overload events and breakers are ultra-low profile. Packaging Includes PDU, Installation guide, Rack Mounting brackets, Safety guide, Serial configuration cable.
Main
Main Input Voltage200 V
208 V
Main Output Voltage200 V
208 V
plug standardNEMA L6-30P
number of rack unit0U
cable length9.84 ft (3.00 m)
number of cables1
Physical
ColorBlack
Height70.51 in (179.1 cm)
Width2.20 in (5.6 cm)
Depth1.73 in (4.4 cm)
Net Weight15.08 lb(US) (6.84 kg)
Mounting LocationSide
mounting preferenceNo preference
Mounting ModeRack-mounted
USB compatibleNo
Input
Line Rated Current24 A
Acceptable Input Voltage200…240 V
input current limits30 A
Load Capacity4992 VA
Input Frequency50/60 Hz
Output
number of power socket outlets36 IEC 60320 C13
6 IEC 60320 C19
Conformance
Product CertificationsMETI Denan
PSE
VDE
standardsCSA C22.2 No. 60950
IEC 60950
UL 60950-1
Environmental
Ambient Air Temperature for Operation23…140 °F (-5…60 °C)
Relative Humidity5…95 %
operating altitude0...10000 ft
Ambient Air Temperature for Storage-13…149 °F (-25…65 °C)
Storage Relative Humidity5…95 %
storage altitude0…50000 ft (0.00…15240.00 m)