Dental Endo Activator Endodoncia Ultrasonic Irrigator Root Canal Bioceramic Seal

DESCRIPTION
 
Advantages:
1.Specially design for Difficult root canal cases
2.Streamlined handle, easy to operate
3.Has 3 variable from low to high ,it can be adjusted to your preference.
4.Dual Purpose device:
5.2 Popular colors you could chosse welcome to do OEM/ODM to customise the color you want.
6.Battery changed easily.
 
Package List:
Main Unit 1 PC
Protective Barrier 100 PCS
Needle Tips:
2/15  10 PC
4/25  10 PC
4/35  10 PC
 
 
 
1. Indications For user
The Easydo Activator system uses technology of sonic energy for root canal treatment. The driver work with the Hand device, motor and needle tip to provide power for tip oscillation and vibration. Evidence-based endodontics has shown that cavitation and acoustic streaming can improve debridement and the disruption of the smear layer and biofilm.
The Activator helps the fluids streaming enter the Pulp Chamber, Root Canal, Lateral canal, Connection of inter-root canal and root apex to ensure deep cleaning and sterilization of root canal. It is beneficial to complete the 3D filling of the root canal and ensures long-term success.
2. Notice
1) Remove the needle tip of EasyDO Activator. If your treatment process is
over, please leave it for medical recycling.
2) Please put exhaustively discharged battery into the recycling box.
3Do not submerge the unit in water.
4Do not autoclave the unit.
3. Precautions
1) The EasyDO Activator system is only used by dental professionals.
2) The EasyDO Activator system is comprised of the Hand device and Activator needle tips of various sizes. If the system functions are used correctly, the equipment can maintain a normal operation. It is strictly prohibited to use non-original components, which will damage the equipment and make it unable to work normally. The original components include the Easydo activator hand device, needle tip and protective cover.The Easy smile reference number of the hand device EASYDO Activator-M10821
The reference numbers of the EasyDO
Activator Needle tip
M10822-015 (Small)
M10822-025 (Medium)
M10822-035 (Large)
 
3The handle device provides three speeds sonic motor adjustment options
(High, Med, Low). The speed gears switch setting adjustment is ultimately
determined by the procedure to be performed, the cliniclan' experience can
efficiently complete the clinical task.
4) The handle device don’t require calibration for normal use.
5) All clinical treatment should be performed with Easydo activator
protective barrier sleeve that placed over the hand device.
6) In the course of treatment, we should use sterilized and individually
packed needle tip, otherwise it will cause root canal infection.
7) It is necessary to use EasyDO Activator system correctly according to
treatment specifications and operation manual to prevent injury to patients.
8) Improper using of the hand device may result in broken handle of the
equipment and damage of internal components.
9) The EasyDO Activator needle tips and protective sleeve are intended for
single-patient use only. Cross contamination may occur to the patient if
needle tips and protective barriers are re-used.
 
 
4. Warranty information of EasyDO activator
1The EASY IN SMILE company provides users with quality assurance within one year from the date of purchase of this product. In case of any
failure due to the defect of Hand device material or production process of the mainframe within this year, the EASY IN SMILE company will provide equipment repair or replacement products.
2The warranty does not include consumables such as needles, batteries, etc.
3If the equipment is damaged due to improper use and maintenance,
or maintenance personnel repair or change of spare parts without the
authorization of EASY IN SMILE, the warranty policy is invalid.
4Under any condition, neither EASY IN SMILE nor its affiliates are
responsible for any special, incidental, or consequential liability
resulting from a violation of the warranty policy, contract, or any other
legal policy. Such damages include but are not limited to loss of
investment, loss of profits, loss caused by wrong use of product
functions, etc.; including but not limited to third party claims and
increase of service cost caused by any alternative equipment, etc.
 
5Warranty limitations
Content not covered by warranty:
-Needle tip
-Hand device barrier sleeve
-Damage caused by misuse, abuse, neglect of prompt or change of the
equipment usage
-Normal wear and other external scratches, including scratches, wear,
cracks, discoloration or fade.
-Battery replacement
* Note:
If the product is not used for a long time (two weeks or longer), please
remove the battery. It also must be removed during transport, for
example, during delivery
 
10) Properly dispose the Activator needles tip and hand device protective
barriers in accordance with the local laws and regulations and environmental
protection requirements.11) Dispose the battery after being used in accordance with the local laws
and regulations and environmental protection requirements, when battery is
exhausted.
12) The hand device must be repaired if necessary according to the direction
of the manufacturer.
13) Don’t insert needle tip into the hand device. If the equipment is not used
for a long time, placing the hand device into packing box is recommended.
14) Remove the battery when the hand device is not used for a long time.
15) The hand device can be kept at the temperature of 0 ℃ ~ 55 ,
relative humidity 0% ~ 75% RH and air pressure750-1060 HPA.
16) The hand device should be keep away from strong electromagnetic
interference, which may affect the performance and normal use of hand
device.
17) The hand device should be kept away from portable or mobile RF
communication devices, which may affect the performance of hand device .
18) The hand device could not be adjacent to or stored with other equipment.
In addition, it is necessary to check regularly whether the hand device can
work normally.
19) Proper disposal of the hand device is required when the hand piece
is deemed no-functional in accordance with local laws and regulations.
6.Product parameters
Name
EasyDO Activator
Model
EASYDO Activator-M1082
Function
Debridement / disinfection / root canal therapy
Use environment
Indoor environment; Temperature range: 0 ℃ ~ + 55 ; Relative
Humidity: 0% ~ 75% RH; Air Pressure: 750-1060 HPA
Power Supply
DC1.0v~1.5v
Battery
AA grade LR6, 1.5v mercury-free alkaline dry battery
Size
L 183mm * W 23mm * H43.1mmGross Weight
124g
7.Operation / Step
Preparation:
1) Prepare the root canal to produce a fully tapered shape.
2) Fill pup chamber with NaOCI, EDTA, or final rinse soulution.
3) Select the needle tip that manually fits loosely within 2mm of the
working length.
4) Place the barrier sleeve over the complete length of the hand device.
5) Connect the needle tip to the hand device with the barrier sleeve. The
activator should snap on firmly, promoting a secure connection with the
hand device.
6) Press ON/OFF button for 1 second, you can see the battery power
status. If the power is enough, you can continue the treatment. If the
power is not enough, you need to replace the battery.
7) Place the attached needle tip into the prepared root canal.
8) Drepress the ON/OFF button to actvate. Switch defaults to high speed
upon activation. Depress the 3-speed switch to select medium speed or
low speed.
9) Use a pumping action to move the hand device in short 2~3 mm
vertical strokes.
10) Hydro dynamically agitate the medical solution for about 30-60
seconds.
11) After washing, use a suction pipe to remove loose debris and
sundries from the root canal.
12) Repeat the above steps for each different root canal treatment.
* when the clinical procedure has been completed, remove the
protective barrier sleeve, remove the needle tip and store it in the medical waste recycling box. The needle tip and protective sleeve are
intended for single-patient used only.
Other instructions: if the EasyDO Activer hand device has been working
for 8 minutes without any operation, or there is no operation after the
equipment stops working, it will enter the state of self-protection
system and power oFF. If you need it to restart , please depress the
ON/OFF switch.
8. Key points of Operation:
5.1POWER OF BATTERY STATUS
Depress the " ON / OFF Switch" key for 1 second to observe the "Power
Indicator" status around the button of the hand device.
1. If the "Power Indicator" is white, it means the activator system is in
full power status;
2. if the "Power Indicator" is red and white, it means the system is in
half power status;
3. if the "Power Indicator" is red, it means the system is in power
shortage status; 4. If the "Power Indicator" is flashing red, it indicates that the system is
on the verge of power failure.
5. Please note if the "power indicator" is flashing red, please replace the
battery.
FDA
The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item.

USA CHIEF OFFICE:EASYINSMILE(USA)INTERNATIONAL CORP.
CHINA FACTORY:CHANGSHA EASYINSMILE MEDICAL INSTRUMENT CO LTD
Room A501, A502, A504, Jinqiyuan Incubation Mansion, No. 229
410000 Changsha
China
Phone:0086-18373188632
Feedback
Your feedback is VERY important to us

Please leave us positive feedback, an positive feedback will be automatically left for you once we receive your full payment.

Please leave us with any concerns prior to leave negative feedback, as we can only correct issues when we are aware of them.

We understand the concerns and frustrations you might have, and will try our best to resolve the isuues.

We will try our best to give you the best service and purchase experience.
Returns
If the item you received is damaged or defective,Please send message immidately.We will free exchange or refund.

You can return your purchase for up to 15 days from the date of delivery. No refund will be issued if the product shows signs of use. Returned package must be in the original packaging, everything must be in new condition, No missing parts.

Our guarantee does not cover accidental damage or wear of product caused by customer.Thank you very much for your understanding!
About us
Easyinsmile(USA)International Corp. is a professional Large-scale Manufacturer of all types of dental instruments and related products,integrating development and production.Our company regards"Reasonable prices,efficient production time and good after sale service" as our tenet.We hope to cooperate with more customers for mutual development and benefits.We welcome potential buyers to contact us.
Contact us
If you send message immediately after placing the order, we will make every effort to assist you with your change request. Unfortunately, we can not make changes or cancel an order once it has shipped.

We offer the best items at the best prices. We strive to exceed all your expectations and put a smile on your face.

Your experience will be a pleasant and effortless one. We stand behind our products and pride ourselves on OUTSTANDING customer service. We guarantee that you will be delighted with your purchase or we will gladly and promptly issue you a refund or make things right!

FEATURED PRODUCTS

Copyright ©easyinsmile_de. All rights reserved.
PushAuction