Ventilation System Solo RA1-35-9 R - Local Residential With Wärmerückgewinnu

The description of this item has been automatically translated. If you have any questions, please feel free to contact us.


Description:

Ventilation system SOLO RA1-35-9 R - decentralized living space ventilation with heat recovery, IP24. Tube length: 380 mm

The ceramic element does not have to be replaced during normal use, filters are available. The device can also be dismantled and cleaned after assembly.
Technical specifications:
Voltage: 230V / 1F / 50Hz
Power: 1.36 / 1.89 W.
Current: 0.031 / 0.034 A
Air flow: 30/46 m3 / h
Filter: G3
Transported air temperature: from -30 to 50 ° C
Noise level - 3 m: 27/32 dB (A)
External noise attenuation: 40 dB (A
Heat recovery efficiency: = 85%
Protection class: IP 24
Characteristics:
- clean, fresh air,
- ventilation of rooms,
- keeps dust and insects away,
- prevents the accumulation of moisture and mold,
- protects against outside noise,
- recovers heat and provides moisture balance in interior rooms,
- reduces costs for heating in winter and air conditioning in summer,
- energy efficient.
Operational logic of the Solo ventilation systems:
The ventilation system can work in reversible mode with energy recovery or only in supply or exhaust air mode without energy recovery.
CYCLE I. The warm exhaust air is extracted from the room via the ceramic heat accumulator. The exhaust air heats and humidifies the heat accumulator. This transfers up to 90% of the thermal energy. After a while, the heat storage tank is heated up and the ventilation system switches to supply air mode.
CYCLE II. The fresh, cold outside air flows over the heat accumulator and removes the stored heat and moisture from the heat accumulator until room temperature is reached. When the heat storage tank is cooled down, the ventilation system switches back to exhaust air mode. The cycle starts again. The switchover to the supply and exhaust air mode takes place every 70 seconds.

Note: German operating instructions are not always included with our products.
We will of course be happy to answer any questions you may have after the purchase.

The ceramic element does not have to be replaced during normal use, filters are available. The device can also be dismantled and cleaned after assembly. CYCLE I. The warm exhaust air is extracted from the room via the ceramic heat accumulator. The exhaust air heats and humidifies the heat accumulator. This transfers up to 90% of the thermal energy. After a while, the heat storage tank is heated up and the ventilation system switches to supply air mode. CYCLE II. The fresh, cold outside air flows over the heat accumulator and removes the stored heat and moisture from the heat accumulator until room temperature is reached. When the heat storage tank is cooled down, the ventilation system switches back to exhaust air mode. The cycle starts again. The switchover to the supply and exhaust air m
Spannung 230V/1F/50Hz
Leistungszahl (EER) 3 oder weniger
Luftvolumenstrom 46 m3/h
Stromquelle Netzbetrieb
Marke Vents
Kältemittel kein
Farbe Weiß
Energieeffizienzklasse A
EAN Nicht zutreffend
EEK Spektrum A+++ - D
Gebläsemotor-Geschwindigkeitseinstellung Mehrstufige Hochleistung
Modell Solo RA1-35-9 R
Herstellernummer Nicht zutreffend
Herstellernummer SOLO RA1-35-9 R
Leistungsphase 1 Phase
Produktart Lüftungsanlage