Product Description



Feature
Specifications



Operation

1. Preparing For Operation

    After checking that all the parts are intact and complete, position the machine on flat.

    Fill the consumable into feed port when power off

    Always connect the product to a grounded circuit. Before power on, make sure it is connected with the rated voltage.

    Turn on the machine, it will immediately start heating up.

2. On-device Manual Control

    To access the control panel functions, use the four buttons located underneath the LCD display.


 

 

 Button  Function
   Switch menu pages to select a function
   Inceases the numeric value of current function
   Decreases the numeric value of current function

                                                            

 Switch between current menu page and standby page


Menu Page

 Control Board
 Description
 Heating/Ready To Work
 Heating Up/Finish heating up, ready to work
 DMX512 Add
 Set DMX strating address
 Volume Out 100%
 Set the Spark height
 Remote Add
 Set OFF the remote functions and set the remote address
 Manual Test
 Press Enter to trigger spark output manually
 Tip Over
 Set ON/OFF the tip over functions
 Set Heater
 Manually set ON/OFF the heater


4. DMX Channel And Values

 Channel
 Function
 1  0 Spark off, 1-255, Spark higher when the value bigger
 2  0-249 Heat-up off 250-255 Heat-up on


5. Indicators And Updates



 UPDATE  Data update button
 DMX  Lights when receiving a normal signal DMX
 READY  When the light is on, The machine is heated and ready to work
 ERROR/UPDATE  When the light is on, The device is faulty or the data is updated
 HEAT  When the light is on, The machine is heating
 UPDATE  Data update interface


6. Wireless Controller

 Button  Features
 ON  Heat-up on
 OFF  Heat-up off
 5S  Spark work 5s
 10S  Spark work 10s
 20S  Spark work 20s
 Addr1  The remote address 1 spark
 Addr2  The remote address 2 spark
 Addr3  The remote address 3 spark
 High  Spark height level biggest
 Mid  Spark height level middle
 Low  Spark height level lowest
 Stop  Spark stop


6. Fill Spark Seed

    Fill the comsumable into the feed port, NOT into the output nozzle when power off.

    Close the lid securely after filling.

    The capacity of storage bin is 200g.


7. TECHNICAL INFORMATION

    1). Precaution For Use

    After use, should observe whether there are nodules in the nozzle. If yes, it needs to be clean up, otherwise it will affect the spray effect and even     damage the machine.

    2). Machine storage

    Before storing the machine, empty the storage bin, clean it as described in the "Maintenance" section.


    Remove the power cord from mains power, and allow unit tocool down. Empty the storage bin through feed port by inverting the machine.

Keep the machine in dry cool place.

  

Package Content
    •  Cold Spark Machine
    •  DMX Signal Cable
    • Power Line
    •  Remote Control
    • 1 X User Manual

Notes:We won't ship to VIRGIN ISLANDS, PUERTO RICO, ALASKA, HAWAII and GUAM for free. We need to calculate the shipping fee additionally. BUY IT, We will contact you and calculate for you.