vfd

IMPORTANT NOTE

  • The vfd can only drive three-phase asynchronous motors and cannot be used as a power source.
  • If your motor is heavy load, pls choose a higher horsepower vfd than your motor's
  • To protect the VFD, be sure to press the red button "Stop" and turn off the power when you stop using it.

220v-4.0kw(5HP) VFD Specifications

Applicable motor horse-power≤ 3kw(4HP)
Input valtage220VAC(+/-5%) 1 or 3 phase(”R“,”T“ terminals for 1 phase,”R“,”S“.”T“ terminals for 3 phase)
output valtage3 phase 220v
input Frequency47-63Hz
output frequency0-400Hz, 0-50Hz/60Hz
rated current16A (Represents the maximum current the VFD can withstand,this is a fixed value)
Circuit breaker suggestion40A
Wire specification suggestion13 AWG

Function introduction

fan

Motor Control

50hz/60hz motor

DC cooling fan

DC cooling fan low noise, large air volume help vfd heat dissipation, improve product stability

basic parameter for 400hz spindle

For 400hz motor:Set pd005=400,pd004=400,pd003=400,pd072=400,pd144=3000,Then you can start driving the 400hz spindle.

(Note:The VFD is already set to 400Hz by default when it is received)

basic parameter for 3 phase 50/60Hz motor

  • Drive 50/60hz motor:Set pd005=50/60,pd004=50/60,pd003=50/60,pd072=50/60

Multiple terminals

Diverse terminals, more functions for you to choose.

  • Unlike other inexpensive VFDS, this VFD has two sets of terminal functions,Rich of digital and analogy control terminals for versitile control,optional MODBUS (RS485) extension,diversified parameter setting.
  • supports external potentiometer control (connect the "FOR" and "DCM" terminals,than set PD001=1)
  • supports mcah3 function and RS-485 communication (For more information, you can contact the seller, we will send you a video of the basic functions of VFD)

keyboard

Multi-function panel keyboard

  • UP: Progressively increase data or function codes.
  • DOWN: Progressively decrease data or function codes.
  • SET: Enter menus step-by-step, save setting parameters.
  • PRGM: Exit current(or present) state, switch among each states, mainly used to switch monitoring state, exit to previous menu.
  • FWD/REV: 1, Press momentary button to start,release to stop; 2 Switch the rotation direction
  • SHIFT: Switch monitoring parameters at monitoring state, at secondary menu, move data box to process editing position.
  • Kindly Note: If you want to show RPM in the display,please press 'SHIFT' key

Advanced motherboard features

Advanced motherboard features

  • PID control; advanced calculus PID closed-loop arithmetic, quick responding speed and high suitability
  • Easy PLC function can realize 16 legs of speed and inverter control function
  • RS485 communication port, adopting standard international MODBUS main circuit control
  • With extremely strong anti-jamming capability
  • Low output ratting torque0.5HZ-150%, low speed running ability
  • Carrier adjustable by 16KHZ, completely soundless working environment
  • Broad voltage working area, normal running in 304V-456V
  • Auto voltage regulation (AVR) technique, for ensuring the inverter load capability
  • With perfect error protection and short circuit starting protection capability