Please mind  the DMM  UNIT 61E,CRO V1065,

all the opamp under test  , NOT included (for demo.testing only).



You are buying 1  pc  new  old stock K&G 

Multi function opamp tester





This opamp tester can test the basic function of standard package DIP opamp IC , SOP8 SMD opamp(using convertor)  ,TO99  metal can opamp  (using convertor),including single ,dual ,quad opamp as below.


Single opamp IC & SOP8 SMD opamp .

(e.g741, ,AD711,AD811,AD817,CA3130,3140,C811(NEC),LF351,LF356,LF357,LM318,LM6361,LT1217,NE5534 ,OP07,OPA134,TL061,TL071,TL081,UPC811


 

Dual opamp IC & SOP8 SMD opamp .

(e.g.4558,AD712,LF353 ,LF412,LM358,LME49720,

MC082,NE5532,OPA2134,TL072,TL082 )


Quad opamp IC & SOP 8 SMD opamp .

(e.g.LF347 ,LM224,324,OPA4134,TL074,TL084,UA348 ).


This IC tester can  test the static

current consumption, (I+,I-, current test) up to  +/- 19.99mA for V+  &  V-  of supply voltage from 4  to  18V


Input  offset voltage test from 0.01mV to  +/- 19.99mV &  down to  <10uV using ext. DMM


Opamp max. output positive  & negative

voltage swing  test (pulse test)

up to  +/-19.99V.

The  opamp  output can connect  to CRO (analog or digital) for high frequency  response  (appro. 1KHz)  pulse test,see last photo.

 


The opamp supply voltage can select single (For LM224,324  opamp test)  or dual power supply.


It provide 2 fixed DC power supply .+/- 5V ,9V & variable voltage output from

4V to 18V with current limitation  appro. 30mA for V+ & V-.    




You can compare the test result with the datasheet.If the current consumption ,offset voltage is out of tolerance  ,

output voltage cannot swing , output wavefrom (pulse test) abnormal, the opamp under test may be damage or fake.


 

Specification

Main supply voltage: DC6V ,4 pcs 1.5V AA battery or  external power supply type C 5V ,1A


Power consumption :EXT PS 5V, <300mA (Dual opamp 5532 offset test mode,power supply set to +/-15V)


Protection .Internal fuse protection .


Opamp supply voltage under test :appro.+/- 5V ,9V or variable from 4V to 18V max..Current limit  of V+ &  V-,appro.30mA


Pulse  test of opamp input voltage, pulse appro.4Vp or DC 2.5V for +IN  (non inverting input) & -IN (inverting input )

Pulse frequency : Variable from appro.0.08Hz (1.25S) to 0.8Hz(12.5S),( Low range),appro.100HZ to 1KHz (High range)

 


Voltmeter (V+,V-)accuracy,  1% of reading  +1 Digit


Current meter (I+,I-) accuracy,  2% of reading  +1 Digit


 Offset voltage  display accuracy ,(offset voltage >1.00mV) 5% of reading + 2 Digits


Pulse output  voltage display accuracy,  2% of reading  +1 Digit


 Size & Weight : appro. 153 X 153X 50 mm,(Body only) , appro. 0.5kg  net ( no battery included)


Come with test fixture   2 pcs  , SMD to DIP convertor 2 pcs, TO99  to DIP  convertor  1pc,

user manual(English,pdf) with photo & video  .


Condition : new WITHOUT original box, diy


product.



We will ship it by air mail with tracking.


Thanks