Please mind the DMM UNIT 61E,CRO V1065,
all the opamp under test , NOT included (for demo.testing only).
You are buying 1 pc new old stock K&G
Multi function opamp tester
This opamp tester can test the basic function of standard package DIP opamp IC , SOP8 SMD opamp(using convertor) ,TO99 metal can opamp (using convertor),including single ,dual ,quad opamp as below.
Single opamp IC & SOP8 SMD opamp .
(e.g741, ,AD711,AD811,AD817,CA3130,3140,C811(NEC),LF351,LF356,LF357,LM318,LM6361,LT1217,NE5534 ,OP07,OPA134,TL061,TL071,TL081,UPC811
Dual opamp IC & SOP8 SMD opamp .
(e.g.4558,AD712,LF353 ,LF412,LM358,LME49720,
MC082,NE5532,OPA2134,TL072,TL082 )
Quad opamp IC & SOP 8 SMD opamp .
(e.g.LF347 ,LM224,324,OPA4134,TL074,TL084,UA348 ).
This IC tester can test the static
current consumption, (I+,I-, current test) up to +/- 19.99mA for V+ & V- of supply voltage from 4 to 18V
Input offset voltage test from 0.01mV to +/- 19.99mV & down to <10uV using ext. DMM
Opamp max. output positive & negative
voltage swing test (pulse test)
up to +/-19.99V.
The opamp output can connect to CRO (analog or digital) for high frequency response (appro. 1KHz) pulse test,see last photo.
The opamp supply voltage can select single (For LM224,324 opamp test) or dual power supply.
It provide 2 fixed DC power supply .+/- 5V ,9V & variable voltage output from
4V to 18V with current limitation appro. 30mA for V+ & V-.
You can compare the test result with the datasheet.If the current consumption ,offset voltage is out of tolerance ,
output voltage cannot swing , output wavefrom (pulse test) abnormal, the opamp under test may be damage or fake.
Specification
Main supply voltage: DC6V ,4 pcs 1.5V AA battery or external power supply type C 5V ,1A
Power consumption :EXT PS 5V, <300mA (Dual opamp 5532 offset test mode,power supply set to +/-15V)
Protection .Internal fuse protection .
Opamp supply voltage under test :appro.+/- 5V ,9V or variable from 4V to 18V max..Current limit of V+ & V-,appro.30mA
Pulse test of opamp input voltage, pulse appro.4Vp or DC 2.5V for +IN (non inverting input) & -IN (inverting input )
Pulse frequency : Variable from appro.0.08Hz (1.25S) to 0.8Hz(12.5S),( Low range),appro.100HZ to 1KHz (High range)
Voltmeter (V+,V-)accuracy, 1% of reading +1 Digit
Current meter (I+,I-) accuracy, 2% of reading +1 Digit
Offset voltage display accuracy ,(offset voltage >1.00mV) 5% of reading + 2 Digits
Pulse output voltage display accuracy, 2% of reading +1 Digit
Size & Weight : appro. 153 X 153X 50 mm,(Body only) , appro. 0.5kg net ( no battery included)
Come with test fixture 2 pcs , SMD to DIP convertor 2 pcs, TO99 to DIP convertor 1pc,
user manual(English,pdf) with photo & video .
Condition : new WITHOUT original box, diy
product.
We will ship it by air mail with tracking.
Thanks