AN hot air ventilator is designed to distribute hot air from fireplace hood to rooms in the building. It has a thermically and acoustically insulated ventilator and a thermostat. When temperature on the probe reaches the value set, the ventilator turns on automatically. It turns off when temperaure falls down under a value set.


Usage:

air-heating systems
- supply/exhaust ventilation
- only inside buildings

Technical parameters
AN1
AN2
AN3
Efficiency [m3/h]
400
600
800
Power [W]
50
80
118
Voltage [V/Hz]
230/50
230/50
230/50
Current [A]
0,25
0,40
0,60
Working temperture [oC]
0 up to +150
0 up to +150
0 up to +150
Accoustic pressure (sound level) [dB]
65
65
65
Weight [kg]           3.5
4.0
4.5
Dimensions [mm]
290x280x270
307x303x302
363x335x325
Max. transported air temp. [oC]
 150
 150
150
Temp. adjustment range [oC]
10-150
10-150
10-150
Inlets diameter [Spiro]
Ø125
Ø150
Ø150
Warranty:                                  2 years

Speed Controller

 Motor speed controller RO-200 is used to control rotating speed of single - phase motors. It can be used in situation where the motor speed is governed by adjusting the effective voltage given to the winding.


Technical data Value
1. Maximum motor power  [W]   200        
2. Power supply ~230 V / 50 Hz
3 Adjustment range  [% of full motor speed] 10-100
4. Ambient temperature [°C]    0-40
5. Dimensions  [mm] 81x81x71

Usage :
- steering of rotating speed of single-phase motors
- steering of AN air hot ventilator speed
- steering of GCK draught generator speed

BYPASS BAN :
BAN thermostatic bypass with special damper and metal filter is used to prepare air coming into the hot air ventilator. It protects the hot air ventilator from overheating (when motor is not working, for example due to a lack of electricity) by shutting the valve and ejecting air through a damper to another room.
Bypass also stabilizes temperature in the system, by opening a damper and sucking cool air, when the air coming into the ventilator is too hot.
Bypass is also equipped with a metal filter.
Max temperature of incomming air 180 [ºC]
 



 
 


 
All orders are delivered by DPD International Tracked Postag.Delivery time is 5-10 business days.A weekend or a holiday in between, then the term is extended accordingly.
 

Payment : We prefer PAYPAL as a most secure way to make international payment

Invoice : We provide invoices with VAT separately displayed.

Return Policy : Your satisfaction with your order is very important to us.  If you are unhappy with your purchase you have 30 days to return item without any reason. All returns must be returned in the exact condition in which they were sold.  If you do choose to return a product for any reason shipping is the responsibility of the buyer to send the item back to us.  It will also be the buyer's responsibility to pay any shipping charges if you would like to exchange your item.  If a mistake is made on our end we will take care of the shipping charges in full. Buyer will need to contact us prior to returning the item. We will provide detailed information on where to send the item back to us.  Please allow us 5 business days to process your return, inspect the item, to send you a replacement, or refund your purchase. Once you return your item please do not email regarding the status of the return. Returns usually take 2-5 business days to process once we receive the item.
We also recommend: