12L Dental Vacuum Autoclave Sterilizer With Printer Lab Medical Equipment CE Blue Color
Note:Purple and blue color are in stock, please tell us which one you want, or we will send the blue color by default!
Also 16L 18L and 23L autoclave sterilizer are also available. If you need it, please feel free to contact us.
Features:
1. Entire computers controls, the pressure, the temperature digitization demonstraton, enables you to operate the dental sterilizer handily;
2. Jet types steam generator, causes in the pot the temperature to be evener, disinfection deeper level; Pots bodies by 2.5mm stainless steel disposable stretch;
3. Waste water tanks full water alarm sysytem, finished has let the waste water circulation disinfection the possibility, causes the disinfection to have the significance;
4. Automatic failure detections report to the opilce, enable you to grasp the loom as necessary dynamically;
5. Humanity bottom of the opt freeing port designs can dryly cause to be more convenient;
6. The high clear data printing, enable the antiseptic effect to arrive.
Specifications:
Voltage Power: 110V-220V
Tank capacity: 12 liters
Inside dimensions: 240*360mm
Outside dimensions: 640*530*540mm
Weight: 52kg
Color:Purple, Blue
Packing List:
1X 12L Autoclave Sterilizer Vacuum Steam with printer
1X Water draining puipe
1X door spanner
1X device plate
1X power cable
1X Hand-support plate
2X fuse
1X measuring cup
1X operation manual
1X User Manual
Please Note
1. The autoclave must be plced on the horizontal working base.
2. Must use the distilled water for the purpose of lasting the working life.
3. There shall be no clog to the air cooling window on the outer surface.
4. The object apparatus to be sterilized shall be palced on teh device plate with enough clearnace retained in favor of the air circulation inside the sterilizing room.
5. Empty the water inside the cooling water collecting tank frequently. Usually, the cooling water collecting tank shall be emptied once the water storing tank emptied.
6. Must revolve teh door handle to the teminal side while working.
7. Don't open the door of autoclave when seeing the "0" displayed on teh pressure indicator.
8. Not be too closed to the door of the autoclave in case of scald when open the door.
9. Shut off the power before discharging/installing the sealing ring, and the work shall be carried out after further sufficient cooling in case of scald.
10. Don't drag or drop the autoclave during relocation period of the autoclave.
11. The protecting ground shall be reliable.
12. Equipment must be used away from teh magnetic field.