ModuleMe Electronic

DC 12V Digital Display Delay Timer Controller Relay Module Control Switch W/Case

Relay Only

Description :
New upgrades to simplify,to meet customer needs.
Increase the supply anti-reversefunction.
The use of opto isolated input and output,enhanced anti-jamming capabilit
consumption.
Set parameter after power for ever memories.
Signal terminal voltage signal can be maintained for a longtime.
to ensure stability,industrial grade board,class PLC.
Product parameters:
Size:64.2mm*34.8mm*18.5mm.
Relay Specifications:AC 220V 10A or DC 30V 10A.
Quiescent Current:20mA,Operating Current:50mA.
Working voltage:10~16V (if other ranges can be customized).
Signal voltage:4V~20V (if other ranges can be customized).
life:about100,000times,Working temperature:-40~85'C.
 
Selection:After power on,long press K12 seconds later into the select function mode,P1-1~P1-4forchoose.
P1-1 operating modes:a signal to trigger relay, time is up,the relay
disconnect users,You can set relay time T,click K2 the hundreddigital
tube starts flashing,then press K3, the hundred digital change;click K2
ten digital tube starts flashing,then press K3,ten digit changes;click K2
bit digital tube starts flashing, then press K3, single-digit change;then
click K2,; digital pipe does not blink,then press the K3, shifting the
decimalpoint,the decimalpointin abitindicates 0-999minutesin ten
represents 0 to 99.9 seconds withou tadecimalpointrepresents 0-999
seconds;goodchoice,bringing the time setting is completed.Short press
K1,enterfunction offine-tuning settings,triggerthedefaultdelayperiod
is invalid, press K1, during the delay trigger active(re-timing),clickon
the K1, during the delay reset (timer turned off,the relay reset) press
again to repeat the default settings for the first time.
P1-2 operating modes:Asignal trigger ,digital countdown begins,X
seconds after,there lay open Y seconds,then close.Users can set the relay
time X,Y;P1-1different time settings similar to the blue lights that set
the relay time,blue light indicates setting relay off time. Short press K1,
enter function offine-tuning the set,the default trigger is invalid during
the delay,pressK1,during the delay trigger active(re-timing),then click
the first repeat default settings.
P1-3 operating modes:Open X seconds,disconnect Yseconds, infinite
loop.Users can set the relay timeX,Y;time setting similar to P1-2.Short
press K1,enter function offine-tuning set,The default function is:set up
an electric circuit the relay first open, press the K1,there lay first
close.Press again to repeat the default functionality.
P1-4 operating modes:a signal to trigger the relay open but do not start
the timer,when the trigger signal disappears,digital count down begins,X
time after,the relayclose; During the delay,again to the signal,digital
count down canceled, stays energized, the signal disappears, restart
count down; (equivalentto release the button to start timing, commonly
usedin power-offdelay).Users canset the relay time X; time setting similar to P1-1.
 
Package Included :
1PCS x DC12V Delay Timer Control Switch Module
Relay with Case

Type : DDC-331
Product parameters
Working voltage: DC12V (normal working voltage DC10V-16V)
Source: DC4V~20V (usual power supply positive trigger, button, PNP sensor, PLC signal, etc.)
Output capability: It can control devices within 30v5A or within 220v5A
Quiescent current: 20mA, working current: 50mA
Service life: more than 100,000 times;
Working temperature: -40~85 °C;
Net weight: about 26g
Size: 64.2mm*34.8mm*18.5mm
Features
Voltage input anti-reverse circuit, worry-free wiring. Signal input optocoupler isolation, strong anti-interference ability. Set the parameter to power off permanent memory. Powerful flash MCU online programming function, according to user needs can contact the manufacturer to customize the required functions.
Wiring diagram

Function introduction
P-1: The signal triggers the relay to pull in. When the time is up, the relay is disconnected during the delay.
A: Invalid trigger again B: Re-trigger re-clocking C: Trigger relay reset again to stop timing
P-2: The signal trigger start timing time T1, the time is up to the relay pull-in time T2 is disconnected (reset)
A: Invalid trigger again B: Re-trigger re-clocking C: Start delay without triggering power-on
P-3: Cycling: Turn on T1, disconnect T2, infinite loop. For T1 and T2, the time is adjustable; if a parameter is turned ON or OFF, it can be turned on or the power is turned on.
A: The relay is turned on immediately after power-on. B: The relay is turned off and then turned on after power-on.
P-4: There is signal, the relay is closed, the suction is kept, the signal disappears, the timing starts, the time is up, the relay is disconnected, during the delay, the signal is given again, the delay is cancelled, the relay is kept, the signal disappears, and the time is re-timed.
Notes
The relay output is a passive contact that has no live output and controls the on/off of a line.
Package included
1*DDC-331 DC 12V 50mA Digital Display Delay Controller Relay PNP Sensor PLC Signal
  1. We accept PayPal only. But we only Accept your Ebay Address,Please Make sure it's 100% right.
  2. Payment must be received in 5 business days of auction closing.
  3. Please leave note for your special request (e.g. Colors or Size) in PayPal when you pay the order.
  4. Any special request cannot be accepted after 24 hours of payment, because most of orders will be processed instantly and same day dispatched.
  1. We maintain high standards of excellence and strive for 100% customer satisfaction! Feedback is very important to us. We request that you keep in touch with us immediately BEFORE you give us neutral or negative feedback, so that we can satisfactorily address your concerns.
  1. All package need to wait 30 days(US only need 7-10 days),Please take care it.Less than 30 days,we can't take a refund.
  2. If the item is defect when you receive it or you are not satisfied with it, please return it within 14 days for a replacement or money back. But the items must be back in factory condition. Please keep in touch with us and double check the return address before you return it.
  3. If is item is defective in 12 months, you can return it to us. We will send you a new replacement after receiving the defective item.

DataCaciques