Introduction:
ETCR4100 pair of pliers digital phase table is my company has a well- developed specifically for field testing of various phases
of the instrument , with high accuracy, high stability, low power consumption, easy to use features . Can be measured directly in
the case of the circuit under test is not open between the two voltages , currents and phase voltages between the two currents
between , in addition, you can also determine the phase sequence of the three-phase transformer connection group , inductive,
capacitive circuits , test secondary loop and bus differential protection system , read travel protection CT phase relationship
between the groups , check the meter wiring is correct or not .
ETCR4100 double clamp digital phase meter with large LCD display with blue backlight , display clear, exquisite and
luxurious appearance.
ETCR4100 pair of pliers digital phase table for the power , petrochemical, metallurgy , railway , meteorology, industrial and
mining enterprises , scientific research institutions , metering sector.
Technical Specifications:
1. Baseline conditions and working conditions
Affect the amount of |
Baseline conditions |
Working conditions |
Remarks |
Ambient temperature |
23 1 |
-10 ~ 40 |
|
Environmental wet crossing |
40% -60 % |
< 85% |
|
Signal waveform |
Sine wave |
Sine wave |
= 0.05 |
Signal frequency |
50HZ 1HZ |
45HZ ~ 65HZ |
|
Operating voltage meter |
9V 0.1V |
9V 1V |
|
External electric field , magnetic field |
Avoid |
||
Measured wire position |
Approximate geometric center of the test conductor position in jaws |
2. General Specifications
Function |
Various phases , phase sequence test ; transformer groups , inductive, capacitive circuit discrimination |
Power source |
DC9V alkaline batteries (1.5V AA × 6) |
Power consumption |
Turn on the backlight most about 35mA, working about 40 hours of continuous battery |
Off the backlight , instrument consumes about 5mA, for about 300 hours of continuous battery |
|
Display Mode |
LCD display , blue backlight , suitable for dark places |
LCD Size |
70mm × 62mm |
LCD display fields |
64mm × 54mm |
Meter size |
Long generous : 196mm × 92mm × 54mm |
Jaw size |
7.5mm × 13mm |
Sampling Rate |
About 3 times / sec |
Range |
0 ~ 360 |
Accuracy |
3 |
Resolution |
1 |
Measuring the phase of the signal amplitude range when |
When measuring phase U1-U2 : 30V ~ 500V |
When the measured phase I1-I2 : 10mA ~ 10.00A |
|
Measured U1-I2 or I1-U2 phase when : 10V ~ 500V, 10mA ~ 10.00A |
|
Data Retention |
Press HOLD key to keep the test data , "DH" symbol is displayed |
Automatic shutdown |
About 15 minutes after startup , the meter automatically shut down to reduce battery consumption |
Voltage detection |
When the battery voltage is lower than 7.8V ~ 8V, low battery symbol appears , reminding replace batteries |
Instrument Quality |
Host about 550g ( with battery ) , table clamp about 170g × 2, test line about 250g |
Test line length |
1.5m |
Current Clamp Cable Length |
2m |
Working temperature and humidity |
-10 ~ 40 ; 80% Rh or less |
Storage Temperature and Humidity |
-10 ~ 60 ; 70% Rh or less |
Input impedance |
Voltage circuit input impedance is : 2M |
U1U2 measured phase voltage input impedance : 40K |
|
Resistance to pressure |
Between meter line and shell withstand sine wave AC voltage 1000V /
50Hz lasted one minute ; able to withstand voltage inputs between the two sine wave AC voltage 500V / 50Hz trial lasted one minute |
Insulation |
The line between the meter and the shell , 10M between the two voltage inputs |
Structure |
Double insulation |
Configuration Checklist:
Meter |
A Taiwan |
Meter box |
1 |
Current Clamp |
2 |
Test line |
4 ( red and black each 2 ) |
Battery |
6 ( alkaline batteries : 1.5V AA) |
Manual, warranty card, certificate |
1 part |
The standard package don't include batteries.Because,the international air shipping forbid to ship batteries,Hope you can understand .you can buy them in your local store or supermarket.