Description:
The “Forend” Lightning Strike Event Counter is a part of
the “Forend” line of Lightning Protection products.
When the Lightning strikes, the high voltage current goes
through the System wires. Then the counter registers the event for a later
reference. The unit has a 6 digit mechanical display. So, after the single
lightning strike the numerical value changes +1. Numbers add and stay.
Easy
to install - just attach it’s rear side firmly to wires which are going
from Air Terminal above to Grounding Electrode below.
The counter does NOT require any external power supply.
The installation brackets, bolts, and nuts are INCLUDED.
Dimensions -
4.5”x2.5”x2.25” (length with plate 7.25”)
Weight – 1lb
5oz
Operating temperature range: from – 40ºF to + 140ºF
The counter is IP65 rated.
Every counter unit has unique Serial Number.
The lightning strike counter works on electric current inductive effect principal.
…………………………….
You
also might be interested in Earthing Inspection Pits
and in other specific types of clamps for
grounding like Grounding
Rod Clamp and a Pylon Clamp which
provide an uncomplicated access to the grounding rod connection in order to
check its connectivity, to gauge ground resistance, and to perform related
tasks as needed.
We
carry Pivoting
Mast/Pole Bases used to install 2” – 2 ½” poles on the flat
roofs and stretch cords Mast
Clips.
In
addition to that, we offer Plastic Wire Clip/Holder for horizontal flat surfaces like isolated
roofs, floors and a two-wire Plastic Clip –
all for 8 mm wires.
. .
. . . . . . . . . . . . .
The main section of
our Lightning Strike Protection line is an Active
Air Terminals, which are the essence of any "Forend" Lightning Protection
System. That’s the part which actually "does the job".
How
it works? When the lightning strikes in proximity of the protected
structure/house, our Conductor produces an anticipating upward streamer (ready-to-go
path) in order to “catch” the lightning strike current and, finally, redirect
it to the earth through the grounding electrodes.
The most
powerful one is usually used in Commercial Lightning
Protection Systems for buildings and industrial
applications. It covers area 518 feet in diameter. Another one is a mid-size active
device for smaller applications - Lightning Protection Rod
System Conductor and it protects 413 feet diameter teritory.
The lightest one is usually bought by private house owners or small businesses.
It’s ideal for Regular Home
Lightning Protection System and defends 315 feet diameter zone.