CMS5100 patient monitor with NIBP SpO2 PR

               
CMS5100 Patient Monitor adopts Oscillometry for NIBP measuring, Photoelectric Oxyhemoglobin Inspection Technology combining Capacity

Pulse Scanning & Recording Technology for SpO2 measuring. Systolic Pressure(SYS), Diastolic Pressure(DIA), Mean Pressure(MAP), SpO2

and Pulse rate(PR) can be accurately measured.Compact appearance, comprehensive functions, simple and convenient operation,

which is applicable for hospitals, community medical treatment and family.

Features

■Be applicable for adult, pediatric and neonatal for all-round monitoring, easy operation and high cost performance.

■Be applicable for medicine, surgery, operating room, ICU/CCU, emergency room, obstetrics and gynecology, pediatrics.

Built-in rechargeable Li-polymer battery for uninterrupted monitoring.

■Compact and flexible appearance, easy for carrying and be suitable for indoor and outdoor(in ambulance) monitoring.

■With user-friendly interface.

■Display with 2.8'' (320×240) color TFT LCD and red and yellow highlight LED.

■Visual and audible alarm for Systolic Pressure(SYS), Diastolic Pressure(DIA), Mean Pressure(MAP), SpO2 and Pulse rate(PR),

and upper and lower limit of alarm can be set.

■Unique Flash memory, storage for up to 2000 NIBP data and 30000 SpO2 data.

■Convenient and quick in inquiring measurement data, review for NIBP trend graph within 24-hour and SpO2 and Pulse rate(PR) trend graph within 20-hour.

Performance

NIBP monitoring

■Measurement method: Oscillometry

■Measurement mode: manual/auto/continuous.

■Auto measurement interval: adjustable from 1 to 90 minutes.

■Resolution: 1mmHg.

■Accuracy: Maximum Mean deviation≤±5mmHg, Maximum Standard deviation≤8mmHg.

■Self-check function.

■Overpressure protection: double protection for software and hardware.

Range

Adult:

 Systolic pressure: 40mmHg~270mmHg

 Mean pressure: 20mmHg~235mmHg

 Diastolic Pressure: 10mmHg~215mmHg

Pediatric:

 Systolic pressure: 40mmHg~200mmHg

 Mean pressure: 20mmHg~165mmHg

 Diastolic Pressure: 10mmHg~150mmHg

Neonatal:

 Systolic pressure: 40mmHg~135mmHg

 Mean pressure: 20mmHg~110mmHg

 Diastolic Pressure: 10mmHg~100mmHg

Upper and lower limit of alarm

Adult: 

 Systolic pressure: 40mmHg~270mmHg

 Mean pressure: 20mmHg~235mmHg

 Diastolic Pressure: 10mmHg~215mmHg

Pediatric:

 Systolic pressure: 40mmHg~200mmHg

 Mean pressure: 20mmHg~165mmHg

 Diastolic Pressure: 10mmHg~150mmHg

Neonatal:

 Systolic pressure: 40mmHg~135mmHg

 Mean pressure: 20mmHg~110mmHg

 Diastolic Pressure: 10mmHg~100mmHg

SpO2 monitoring 

Continuous real-time measuring.

Adopt digital SpO2 technology, which has strong anti-interference capability.

Real-time display SpO2, pulse rate, SpO2 Plethysmogram, bar graph, SpO2 and Pulse rate(PR) trend graph.

Standard finger-clip probe for adult , binding probe for neonatal is optional.

SpO2 Measuring

Range: 35%~100% (Resolution: 1%)

Accuracy: ±2% in stage of 70%-100%, and unspecified in stage of less than 70%.

Pulse Rate Measuring

Range: 30bpm~250bpm(Resolution: 1bpm)

Accuracy: ±2bpm or ±2%, whichever is greater.

Measurement Performance in Weak Filling Condition: SpO2 and pulse rate can be shown 

correctly when pulse-filling ratio is 0.4%, SpO2 error is ±4%; the Pulse rate error is ±2bpm or ±2%, whichever is greater.

Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and

 that of darkroom is less than ±1%.

Accessories

A power cord

A power adapter

A SpO2 probe

An adult NIBP cuff

An extending tube for blood pressure

Physical characteristic 

Dimension for product: 190(L)×162(W)×240(H)mm

Weight: 1.6kg

Dimension for packaging: 402(L)×228(W)×320(H)mm

Buy safe products

The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE: The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If the item is subject to FDA regulation, we will verify your status as an authorized purchaser of this item before shipping of the item.

The Fingertip Pulse Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG)with the code 197923, and certified by FDA of United States and CE,TUV of Europe. The  Fingertip Pulse Oximeter that is FDA 510K Approved

International Buyer--Please note:

Import duties,Taxes are not included in the item price.These charges are buyers' responsibility


We are the manufacturer of medical equipment for 17 years, the following are our main products:

ECG /  ECG holter   EEG / EEG Holter      B-ultrasound

Patient Monitor      Fetal doppler             Fetal Monitor 

Spo2 Monitor          Stethoscope              Medical Image....

Agent in the world!

We are look for partners in the world now!

Do you want  to become our agent in you conutry?

Join US!

Skype:xuebox3

contec.med.mary at hotmail.com

               
           
       
       
   

Only English User Manual,Please contact us if you need other language version.thank youibay365