Signal Source Rtd Thermocouple Process Calibrator Meter YHS-724


I.Introduction: 
 
The YHS724 Multifunction Process Calibrator is a powerful, yet easy-to-use field calibrator. Use the measure and source functions to test and calibrate almost any process parameter. 
 
  • Small, streamlined shape makes it easy to carry.
  • Rugged, reliable design stands up to field use.
  • Easy to read measure/source screen lets you view input and output simultaneously.
  • Measure volts, mA, RTDs, thermocouples and ohms to test sensors and transmitters.
  • Source/simulate volts, mA, thermocouples , RTDs, frequency, ohms, and pressure to calibrate transmitters.
  • Support flow meter testing with frequency and CPM functions.
  • Perform fast linearity tests with auto- step and auto-ramp features.
  • Power transmitters during test using loop supply with simultaneous mA measurement.
  • Handling of fast pulsed RTD transmitters and PLCs, with pulses as short as 10 ms *Store frequently used test setups for later use.
  • Backlight lets you work in poor light.
  • Large battery capacity of four AA cells.
  • Battery door for easy changes.
  •  

    Feature:
  • A split-screen display. The upper display allows users to measure volts, current, and only. The lower display allows the user to measure and source volts, current, resistance temperature detectors, thermocouples and ohms.
  • A thermocouple (TC) input/output terminal with cold junction temperature compensation, ambient temperature can be set and calibrate within the menu function.
  • Each parameters can manual and automatic stepping and ramping output, signal output can be arbitrarily set within the 0%,25% and 100% of the value.
  • In the configuration menu can be set manually : Power off time for Instrument Backlight off time Screen Contrast Cold junction compensation ON/OFFHART resistence ON/OFF and ETC.
  • Have calendar clock function, it can be calibrated in configuration menu.
  • It can be store 8 sets of measurement and output data and call the showing at any time, all the settings and the functions of the last operation be auto-stored after power off.
  • High capacity rechargeable battery pack, with power adapter, within integrated charge-management functions.
  • Novel shape, large screen dot-matrix graphic display, can display Chinese characters, digital key to input personalized , make the operation more simple.
  •  

    II.Specificatoin:

    Function

    YHS-724

    YHS-726

    Measurement Function

    Upper Screen


     


     

    DC Voltage

    0.000~30.000V

    0.000~30.000V

    DC Current

    0.000~24.000mA

    0.000~24.000mA

    Loop power

    0.000~24.000mA

    0.000~24.000mA

    Under Screen


     


     

    DC V

    0~24.000V

    0~20.000V

    DC mA

    0-24.000mA

    0-24.000mA

    Resistance

    0Ω~ 4000.0Ω

    0Ω~ 4000.0Ω

    Frequency


     

    0.01~ 99.99Hz, 
    1.00~ 15.00KHz

    Sensitivity


     

    200mV peak value ~peak valu

    Pressure


     

    Include 40 kinds of pressure module, range: 
    0 ~70Mpa,   the type include: Gage Pressure, Differential Pressure, Absolute Pressure, Compound  Pressure and Vacuum Pressure.

    Thermocouple (TC)

    Type: S, R, B, K, N, E, J, T,(mV)

    Resistance-Temperature Detector (RTD)

    Pt100(385) Pt100(3926) Pt100(3916) Pt200(385)
    Pt500(385)  Pt1000(385) Cu100(ITS) Cu50(ITS)

    Output Function

    DCV

    0.000~20.000V

    DC mV

    0.000~90.000mV

    DC Current

    0.000~24.000mA

    Resistance

    15.0Ω~ 4000.0Ω

    Frequency


     

    0.01~ 99.99Hz, 
    1.00~ 15.00KHz

    Wave shape

     


     

    Square wave, -0.1V gap, range can adjust(0 ~20V), Duty cycle can adjust (0.3~ 99.7%)

    Thermocouple (TC)

    Type: S, R, B, K, N, E, J, T,(mV)

    Resistance-Temperature Detector (RTD)

    Pt100(385) Pt100(3926) Pt100(3916) Pt200(385)
    Pt500(385)  Pt1000(385) Cu100(ITS) Cu50(ITS)

    Other functions

    Stepping output, Ramping output, Store data A split-screen display.

     

    Measure Accuracy:

    Function


    Measure Singal


    Measure  Accuracy


    Output


     

    DC Voltage


    0.000~30.000 V


    0.02%+3 counts  (The upper display)


     


    0.000~24.000 V


    0.02%+ 3 counts (The lower display)


     


    0.000~90.000 mV


    0.01%+ 10 counts


     


    -10.000~80.000mV 0.01 % + 10 counts (use the thermocouple jack )

    DC Current


    0.000~24.000 mA


    0.02%+ 4 counts(The upper display)


     


    0.000~24.000 mA


    0.02%+ 4 counts(The lower display)


     

    Resistance


    0.00~400.00Ω


    0.1Ω (4 wire), 0.15Ω (2 wire and 3 wire)


     


    400.0~4000.0Ω


    0.5Ω (4 wire), 1Ω (2 wire and 3 wire)

     

    Output Accuracy:

    Output


    Range


        Accuracy


     

    DC Voltage


    0.000 ~20.000 V


    0.02%+3 counts


     


    0.000~90.000 m V


    0.01%+10 counts


     


    -10.000 mV~80.000 mV   0.01 % + 10 counts (use the thermocouple jack )

    DC Current


    0.000~24.000 mA

    Notice: Because,the international air shipping forbid to ship liquid,powder and batteries, If you purchased goods containing such items, we will not be putting them packing. Thank you for your support.



    Payment must be made within 12 days after the auction/bid ends, or eBay will open Unpaid Item case automatically later.


    Please read this before buying International Shipping may Be Delayed Due to Customs. Customers are Responsible For All Import Charges, Tariffs, Duties, Taxes, and Fees Associated with Import of the product. Shipping Charges does not include any Import Charges, Tariffs, Duties, Taxes, and Fees Associated with it. We are not responsible for undeliverable address.
    We reserve the right to charge the shipping fee again for returned items due to wrong address.
    Items are generally shipped within 10 business day after your payment has been cleared (Sat. & Sun. excluded.)



    Dear friend, your happy is very important to me!.we stand behind every product we sell.Your bid is a contract - Place a bid only if you're serious about buying the item. If you are the winning bidder, you will enter into a legally biding contract to purchase the item. If payment is not received within 7 days, item may be offered to the next highest bidder or relisted at the seller's sole discretion.If you're not pleased with your purchase, we'll be happy to make an exchange or refund the product price less S&H within 7 days of your purchase. For any exchange or refund, we need the original receipt or a record of the purchase in our system, and the product must be in its original condition, including the box, packaging, and all accessories.Shipping and handling charges are not refundable. 



    We are professional EBAY sales team and lots of ebay buyers very satisfied with our services.You can enjoy top-quality product and high-quality services from us, Trust me that you will have a pleasant shopping experience in here.



    Please contact us with any comments, questions or suggestions that you may have bysending ebay message, All the mail will be replied within 24 hours. Please ensure your mail box would not blocked / filtered our mails.we will be happy to assist you.please feel free to contact us for WHOLESALES deal,we will surely give you a satisfatory price.We would try our best to serve you with any question / problem. Please contact us first before leaving Negative / Neutral Feedback or open any cases.We work 6 Days a week From 9:00am - 6:00pm Monday - Saturday CHINA Time.



    I.Introduction: 
     
    The YHS724 Multifunction Process Calibrator is a powerful, yet easy-to-use field calibrator. Use the measure and source functions to test and calibrate almost any process parameter. 
     
  • Small, streamlined shape makes it easy to carry.
  • Rugged, reliable design stands up to field use.
  • Easy to read measure/source screen lets you view input and output simultaneously.
  • Measure volts, mA, RTDs, thermocouples and ohms to test sensors and transmitters.
  • Source/simulate volts, mA, thermocouples , RTDs, frequency, ohms, and pressure to calibrate transmitters.
  • Support flow meter testing with frequency and CPM functions.
  • Perform fast linearity tests with auto- step and auto-ramp features.
  • Power transmitters during test using loop supply with simultaneous mA measurement.
  • Handling of fast pulsed RTD transmitters and PLCs, with pulses as short as 10 ms *Store frequently used test setups for later use.
  • Backlight lets you work in poor light.
  • Large battery capacity of four AA cells.
  • Battery door for easy changes.
  •  

    Feature:
  • A split-screen display. The upper display allows users to measure volts, current, and only. The lower display allows the user to measure and source volts, current, resistance temperature detectors, thermocouples and ohms.
  • A thermocouple (TC) input/output terminal with cold junction temperature compensation, ambient temperature can be set and calibrate within the menu function.
  • Each parameters can manual and automatic stepping and ramping output, signal output can be arbitrarily set within the 0%,25% and 100% of the value.
  • In the configuration menu can be set manually : Power off time for Instrument Backlight off time Screen Contrast Cold junction compensation ON/OFFHART resistence ON/OFF and ETC.
  • Have calendar clock function, it can be calibrated in configuration menu.
  • It can be store 8 sets of measurement and output data and call the showing at any time, all the settings and the functions of the last operation be auto-stored after power off.
  • High capacity rechargeable battery pack, with power adapter, within integrated charge-management functions.
  • Novel shape, large screen dot-matrix graphic display, can display Chinese characters, digital key to input personalized , make the operation more simple.
  •  

    II.Specificatoin:

    Function

    YHS-724

    YHS-726

    Measurement Function

    Upper Screen


     


     

    DC Voltage

    0.000~30.000V

    0.000~30.000V

    DC Current

    0.000~24.000mA

    0.000~24.000mA

    Loop power

    0.000~24.000mA

    0.000~24.000mA

    Under Screen


     


     

    DC V

    0~24.000V

    0~20.000V

    DC mA

    0-24.000mA

    0-24.000mA

    Resistance

    0Ω~ 4000.0Ω

    0Ω~ 4000.0Ω

    Frequency


     

    0.01~ 99.99Hz, 
    1.00~ 15.00KHz

    Sensitivity


     

    200mV peak value ~peak valu

    Pressure


     

    Include 40 kinds of pressure module, range: 
    0 ~70Mpa,   the type include: Gage Pressure, Differential Pressure, Absolute Pressure, Compound  Pressure and Vacuum Pressure.

    Thermocouple (TC)

    Type: S, R, B, K, N, E, J, T,(mV)

    Resistance-Temperature Detector (RTD)

    Pt100(385) Pt100(3926) Pt100(3916) Pt200(385)
    Pt500(385)  Pt1000(385) Cu100(ITS) Cu50(ITS)

    Output Function

    DCV

    0.000~20.000V

    DC mV

    0.000~90.000mV

    DC Current

    0.000~24.000mA

    Resistance

    15.0Ω~ 4000.0Ω

    Frequency


     

    0.01~ 99.99Hz, 
    1.00~ 15.00KHz

    Wave shape

     


     

    Square wave, -0.1V gap, range can adjust(0 ~20V), Duty cycle can adjust (0.3~ 99.7%)

    Thermocouple (TC)

    Type: S, R, B, K, N, E, J, T,(mV)

    Resistance-Temperature Detector (RTD)

    Pt100(385) Pt100(3926) Pt100(3916) Pt200(385)
    Pt500(385)  Pt1000(385) Cu100(ITS) Cu50(ITS)

    Other functions

    Stepping output, Ramping output, Store data A split-screen display.

     

    Measure Accuracy:

    Function


    Measure Singal


    Measure  Accuracy


    Output


     

    DC Voltage


    0.000~30.000 V


    0.02%+3 counts  (The upper display)


     


    0.000~24.000 V


    0.02%+ 3 counts (The lower display)


     


    0.000~90.000 mV


    0.01%+ 10 counts


     


    -10.000~80.000mV 0.01 % + 10 counts (use the thermocouple jack )

    DC Current


    0.000~24.000 mA


    0.02%+ 4 counts(The upper display)


     


    0.000~24.000 mA


    0.02%+ 4 counts(The lower display)


     

    Resistance


    0.00~400.00Ω


    0.1Ω (4 wire), 0.15Ω (2 wire and 3 wire)


     


    400.0~4000.0Ω


    0.5Ω (4 wire), 1Ω (2 wire and 3 wire)

     

    Output Accuracy:

    Output


    Range


        Accuracy


     

    DC Voltage


    0.000 ~20.000 V


    0.02%+3 counts


     


    0.000~90.000 m V


    0.01%+10 counts


     


    -10.000 mV~80.000 mV   0.01 % + 10 counts (use the thermocouple jack )

    DC Current


    0.000~24.000 mA

    ibay365