Overview
• Probe
- Spring-loaded for positive tip contact in thermowells
- 100 ohm platinum RTD 3-wire element
- Class A accuracy
- 1/4” diameter, 316 SS sheath to protect against harsh
environments
- RTD element encased in alumina powder insulation
provides excellent vibration dampening and heat
transfer
- 4”, 6” or 12” probe length
• Connection Head
- Cast aluminum NEMA 4X, IP66 screw cover head with
captive gasket
- One turn cover removal & installation eliminates cross
threading and saves time
- 3/4 NPT conduit opening with internal stop to prevent
overtightening and installation damage
- Gripping ribs on cover edge
- Stainless steel cover chain
• Wiring
- Ceramic terminal base
- Brass terminals with stainless steel screws eliminate the
need to wrap connections around screws
- Elevated terminal block for easy wire
termination