Kidde KF20LL Firex Mains Powered Optical Smoke Alarm Longlife Lithium Battery Back Up

Mains-powered optical (photoelectric) smoke alarm that can be interlinked by cable with up to 23 other Kidde branded mains alarms. Once interlinked, the detection of the relevant danger by an individual unit will sound across all the connected alarms. Back up provided by long life lithium non replaceable battery. 

Optical alarms are for use in escape or circulation routes and in areas where there is a danger of ignition of furniture and surroundings by cigarettes producing slow, smouldering fires. 

These alarms comply with UK Building Regulations for new housing and associated standards (Grade D BS 5839, Part 6). 

Not for use in kitchens, boiler rooms or garages (use KF30LL Heat Alarm instead).
  • Interlink with up to 23 Firex branded hard-wired alarms – all alarms sound if danger is detected
  • Alarm memory – identifies source unit within interconnecting network
  • Reduced energy consumption – lower lifetime running costs
  • Combined Test and hush button allows regular testing of alarm function and can be used to temporarily silence nuisance alarms
  • Auto reset after activation
  • Tamper-resistant locking device – prevents unauthorised removal without the use of a tool
  • Mains operation – 9V Alkaline back-up battery supplied as standard
  • Sensor Optical, circular lateral chamber with insect-resistant width, 9-slot entry portals
  • Button Test Simulates the effect of smoke within the sensing chamber, checks electronics and sounder
  • Automatic Self-test Circuitry is tested and unit beeps (chirps) if fault is detected
  • Supply Voltage 230V AC, 50 Hz (nominal UK voltage)
  • Power Consumption < 15mA
  • Connection Push-in/snap-fit type connector with 150mm long flying leads (supplied) - see photos
  • Power-on Indicator Continuous green LED
  • Alarm Sounder Electronic piezo-electric sounder (T3 pattern sound - three pulses - space - three pulses) with soldered contacts
  • Sound Output 85dB (A) minimum at 3 metres
  • Alarm Frequency 3.2 kHz typical
  • Dust Protection In-built foam gasket in rear of alarm to prevent dust ingress into rear of the alarm
  • Alarm Status Red LED flashes approx once every five minutes = normal operation
  • Red LED flashes once a second = sensing smoke (sounder alarm sounds)
  • Red LED flashes once every ten seconds = in hush condition (auto-reset after 15 minutes)
  • Interconnection Up to 23 Firex and Kidde ‘Slick’ units (smoke, heat and CO) can be hardwire interconnected
  • SMK4896 – Surface mounting base for added ease of installation - sold separately
  • Kitemarked BS5446 Pt 2: 2003
  • UKCA & CE certified
We stock the matching heat alarm. Please click here to find the listing.

Cabling requirements:-

1.0mm or 1.5mm 6242Y Twin & Earth cable to the first alarm position, then 1.0mm or 1.5mm 6243Y 3 Core & Earth cable from the first alarm position to the second alarm and so on in a "radial" or "daisy chain" type circuit arrangement.

Dimensions: 130mm diameter x 50mm deep

VAT INVOICE ON REQUEST

Collection available
Monday - Thursday: 7.30am - 4.30pm