CEME coffee machine pressure switch.

Typically if you pressure switch is faulty, the heating element will not switch on.   Occasionally, the
opposite will occur, and the element will not turn off, although usually an overheat thermostat will
trip and the machine will then appear dead.  If the element operates intermittently, it is usually a sign
that the contacts are burned and pitted and a replacement thermostat is required.

Description

  • used by many manufacturers
  • model number CEME PC 5412/VAP-DR
  • changeover contacts
  • pressure setting: 1.3bar (adjustable 0.2 bar to 6.0 bar approximately)
  • contact rating: 15A at 250vAC (NC contact) 9A at 250Vac (NO contact)
  • G1/4 thread