An amazing meter ever made ! All in one unit made according to IEC1010 and CAT III 600V and pollution grade 2. Max show digits: -8888

 

It has all feature that regular multimeter has, but many features that you have to pay 4 times more to get them: A sound level meter, Lux Meter, Thermometer and Humidity Meter. All the features are for high accuracy, all the sensor are built in, just one meter in your pocket, you can do so many works just by one meter.

 

Specifications of the MS8209 5 in 1 meter

As a multimeter

DC Voltage

Range Resolution Accuracy
400mV 0.1mV ± (0.7% of reading + 2 digits)
4V 1mV ± (0.7% of reading + 2 digits)
40V 10mV ± (0.7% of reading + 2 digits)
400V 100mV ± (0.7% of reading + 2 digits)
600V 1V ± (0.7% of reading + 2 digits)
Input impedance: 10 M Ohm
Over load protection: 400mV Range 250V DC or rms AC, 4V-6 00V ranges: 600V DC or rms AV, Max input voltage : 600V DC or rms AC

AC Voltage

Range Resolution Accuracy
4V 1mV ± (0.8% of reading + 3 digits)
40V 10mV ± (0.8% of reading + 3digits)
400V 100mV ± (0.8% of reading + 3 digits)
600V 1V ± (0.8% of reading + 3 digits)
Input impedance: 10 M Ohm
Over load protection: 400mV Range 250V DC or rms AC, 4V-6 00V ranges: 600V DC or rms AV, Max input voltage : 600V DC or rms AC
Frequency range: 40 to 1000Hz,
Resonse: Average, calibrated in rms of sine wave.

DC Current

Range Resolution Accuracy
40mA 10uA ± (1.2% of reading + 3 digits)
400mA 100uA
10A 10mA ± (3.0% of reading + 10 digits)
mA ranges: F500mA/250V fuse (quick acting),10A range: unfused. Max. Input current:mA jack:400mA,10A jack :10A; Voltage Drop: ma ranges :5mV/1mA, 10A range: 10mV/1A

AC Current

Range Resolution Accuracy
40mA 10uA ± (1.5% of reading + 5 digits)
400mA 100uA
10A 10mA ± (3.0% of reading + 10 digits)
mA ranges: F500mA/250V fuse (quick acting),10A range: unfused. Max. Input current:mA jack:400mA,10A jack :10A; Voltage Drop: ma ranges :5mV/1mA, 10A range: 10mV/1A
Resonse: Average, calibrated in rms of sine wave.

Resistance

Range Resolution Accuracy
400 Ω 0.1Ω ± (1.2% of reading + 2 digits)
4KΩ 1Ω
40KΩ 10Ω
400KΩ 100Ω
4MΩ 1KΩ
40MΩ 10Ω ± (1.2% of reading + 2 digits)
Open Circuit Voltage:0.25V, Overload Protection: 250V or rms AC

Capacitance

Range Resolution Accuracy
4nF 1pF ± (3.0% of reading + 3 digits)
40nF 10pF
400nF 0.1nF
4uF 1nF
40uF 10nF
200uF 100nF
Overload Protection: 250V DC or rms AC

Frequency

Range Resolution Accuracy
9.999 Hz 0.001Hz ± (2.0% of reading + 5 digits)
99.99Hz 0.01 Hz ± (1.5% of reading + 5 digits)
999.9 Hz 0.1Hz
9.999 KHz 1 Hz
99.99 KHz 10 Hz ± (2.0% of reading + 5 digits)
199.9 KHz 100 Hz
>200 KHz Reference only
By Hz Range:

Range: 0 - 200 KHz

Input Voltage: 0.5V - 10V rms AC

By V Range:

Range: 0 - 40 KHz

Input Voltage range: 0.5V - 600V rms AC, Input impedance: 10MΩ

By mA Range:

Range: 0 -40 KHz, Input current range: 100mA- 400mA rms AC

Duty Cycle

Range Resolution Accuracy
0.1 - 99.9 % 0.1% ± 3.0%
Note: When measuring frequency, the range by Duty of Hz range is larger than by Duty of voltage ot current range. More to see on the manual book.

Diode

Range Resolution Accuracy
Diode 1mV Display: read appromix forward voltage of diode

Continuity

Built in buzzer will sound if the resistance is lower than 40 Ohms.

As a Thermometer

Range Resolution Accuracy
0.1

 

0.1℃

 

-20℃ to 0 ℃ ± (5.0% of reading + 8 digits)
0℃ to 20 ℃ ± (3.0% of reading + 8 digits)
20 ℃ to 400℃ ± (2.0% of reading + 5 digits)
0.1℃ 1 -20℃ to 0℃ ± (5.0% of reading + 5 digits)
0℃ to 400℃ ± (1.0% of reading + 3 digits)
400℃ to 1000℃ ± (2.0% of reading + 3 digits)

As a Humidity Meter

Range Resolution Accuracy
30 - 90 % 0.1% ± 5.0% RH
Response time: 45% - 90 %RH < 10 Minutes, 90% - 45% < 15 Minutes

As a Sound Level Meter

Range Resolution Accuracy
30dB - 100dB 0.1dB ± 3.5% dB at 94 dB, 1K Hz sine wave.

Lux Meter

Range Resolution Accuracy
Lux ( 4000) 1 Lux ± (5.0% of reading + 10 digits) at color temp. 2850K, calibrated to standard incandescent lamp at color temperature 2856 K
X 10 Lux ( 40000) 10 Lux