An amazing meter ever made ! All in one unit made according to IEC1010 and CAT III 600V and pollution grade 2. Max show digits: -8888
It has all feature that regular multimeter has, but many features that you have to pay 4 times more to get them: A sound level meter, Lux Meter, Thermometer and Humidity Meter. All the features are for high accuracy, all the sensor are built in, just one meter in your pocket, you can do so many works just by one meter.
Specifications of the MS8209 5 in 1 meter | |||
As a multimeter | |||
DC Voltage | |||
Range | Resolution | Accuracy | |
400mV | 0.1mV | ± (0.7% of reading + 2 digits) | |
4V | 1mV | ± (0.7% of reading + 2 digits) | |
40V | 10mV | ± (0.7% of reading + 2 digits) | |
400V | 100mV | ± (0.7% of reading + 2 digits) | |
600V | 1V | ± (0.7% of reading + 2 digits) | |
Input impedance: 10 M Ohm | |||
Over load protection: 400mV Range 250V DC or rms AC, 4V-6 00V ranges: 600V DC or rms AV, Max input voltage : 600V DC or rms AC | |||
AC Voltage | |||
Range | Resolution | Accuracy | |
4V | 1mV | ± (0.8% of reading + 3 digits) | |
40V | 10mV | ± (0.8% of reading + 3digits) | |
400V | 100mV | ± (0.8% of reading + 3 digits) | |
600V | 1V | ± (0.8% of reading + 3 digits) | |
Input impedance: 10 M Ohm | |||
Over load protection: 400mV Range 250V DC or rms AC, 4V-6 00V ranges: 600V DC or rms AV, Max input voltage : 600V DC or rms AC | |||
Frequency range: 40 to 1000Hz, | |||
Resonse: Average, calibrated in rms of sine wave. | |||
DC Current | |||
Range | Resolution | Accuracy | |
40mA | 10uA | ± (1.2% of reading + 3 digits) | |
400mA | 100uA | ||
10A | 10mA | ± (3.0% of reading + 10 digits) | |
mA ranges: F500mA/250V fuse (quick acting),10A range: unfused. Max. Input current:mA jack:400mA,10A jack :10A; Voltage Drop: ma ranges :5mV/1mA, 10A range: 10mV/1A | |||
AC Current | |||
Range | Resolution | Accuracy | |
40mA | 10uA | ± (1.5% of reading + 5 digits) | |
400mA | 100uA | ||
10A | 10mA | ± (3.0% of reading + 10 digits) | |
mA ranges: F500mA/250V fuse (quick acting),10A range: unfused. Max. Input current:mA jack:400mA,10A jack :10A; Voltage Drop: ma ranges :5mV/1mA, 10A range: 10mV/1A | |||
Resonse: Average, calibrated in rms of sine wave. | |||
Resistance | |||
Range | Resolution | Accuracy | |
400 Ω | 0.1Ω | ± (1.2% of reading + 2 digits) | |
4KΩ | 1Ω | ||
40KΩ | 10Ω | ||
400KΩ | 100Ω | ||
4MΩ | 1KΩ | ||
40MΩ | 10Ω | ± (1.2% of reading + 2 digits) | |
Open Circuit Voltage:0.25V, Overload Protection: 250V or rms AC | |||
Capacitance | |||
Range | Resolution | Accuracy | |
4nF | 1pF | ± (3.0% of reading + 3 digits) | |
40nF | 10pF | ||
400nF | 0.1nF | ||
4uF | 1nF | ||
40uF | 10nF | ||
200uF | 100nF | ||
Overload Protection: 250V DC or rms AC | |||
Frequency | |||
Range | Resolution | Accuracy | |
9.999 Hz | 0.001Hz | ± (2.0% of reading + 5 digits) | |
99.99Hz | 0.01 Hz | ± (1.5% of reading + 5 digits) | |
999.9 Hz | 0.1Hz | ||
9.999 KHz | 1 Hz | ||
99.99 KHz | 10 Hz | ± (2.0% of reading + 5 digits) | |
199.9 KHz | 100 Hz | ||
>200 KHz | Reference only | ||
By Hz Range:
Range: 0 - 200 KHz Input Voltage: 0.5V - 10V rms AC By V Range: Range: 0 - 40 KHz Input Voltage range: 0.5V - 600V rms AC, Input impedance: 10MΩ By mA Range: Range: 0 -40 KHz, Input current range: 100mA- 400mA rms AC | |||
Duty Cycle | |||
Range | Resolution | Accuracy | |
0.1 - 99.9 % | 0.1% | ± 3.0% | |
Note: When measuring frequency, the range by Duty of Hz range is larger than by Duty of voltage ot current range. More to see on the manual book. | |||
Diode | |||
Range | Resolution | Accuracy | |
Diode | 1mV | Display: read appromix forward voltage of diode | |
Continuity | |||
Built in buzzer will sound if the resistance is lower than 40 Ohms. | |||
As a Thermometer | |||
Range | Resolution | Accuracy | |
0.1℃
|
0.1℃
|
-20℃ to 0 ℃ | ± (5.0% of reading + 8 digits) |
0℃ to 20 ℃ | ± (3.0% of reading + 8 digits) | ||
20 ℃ to 400℃ | ± (2.0% of reading + 5 digits) | ||
0.1℃ | 1 ℃ | -20℃ to 0℃ | ± (5.0% of reading + 5 digits) |
0℃ to 400℃ | ± (1.0% of reading + 3 digits) | ||
400℃ to 1000℃ | ± (2.0% of reading + 3 digits) | ||
As a Humidity Meter | |||
Range | Resolution | Accuracy | |
30 - 90 % | 0.1% | ± 5.0% RH | |
Response time: 45% - 90 %RH < 10 Minutes, 90% - 45% < 15 Minutes | |||
As a Sound Level Meter | |||
Range | Resolution | Accuracy | |
30dB - 100dB | 0.1dB | ± 3.5% dB at 94 dB, 1K Hz sine wave. | |
Lux Meter | |||
Range | Resolution | Accuracy | |
Lux ( 4000) | 1 Lux | ± (5.0% of reading + 10 digits) at color temp. 2850K, calibrated to standard incandescent lamp at color temperature 2856 K | |
X 10 Lux ( 40000) | 10 Lux |