USA 50'FT Cat5e Outdoor Burial Ethernet Cable patch waterproof network copper

One Cable Long with 2-RJ45 "Attached" Terminated on the end of Cable.

 

Brand New – Factory Sealed  -  Lowest price

Our strategy is to provide the customer with direct access to wholesale prices. Please contact us with any questions you may have, we will work hard to make sure your transaction is as quick and smooth as possible

 

 

 

Product Classification

Regional Availability

Latin America | North America

Portfolio

CommScope®

Product Type

Twisted pair cable

General Specifications

Product Number

5NF4

ANSI/TIA Category

5e

Cable Component Type

Horizontal

Cable Type

U/UTP (unshielded)

Conductor Type, singles

Solid

Conductors, quantity

8

Jacket Color

Black

Note

All electrical transmission tests include swept frequency measurements

Pairs, quantity

4

Transmission Standards

ANSI/TIA-568.2-D | CENELEC EN 50288-3-1 | ISO/IEC 11801 Class D

Dimensions

Cable Length

304.8 m | 1000 ft

Diameter Over Jacket, nominal

6.096 mm | 0.24 in

Jacket Thickness

0.762 mm | 0.03 in

Conductor Gauge, singles

24 AWG

Cross Section Drawing

Click on image to enlarge.

Electrical Specifications

Characteristic Impedance

100 ohm

dc Resistance Unbalance, maximum

5 %

dc Resistance, maximum

9.38 ohms/100 m | 2.859 ohms/100 ft

Delay Skew, maximum

45 ns

Dielectric Strength, minimum

1500 Vac | 2500 Vdc

Mutual Capacitance at Frequency

4.6 nF/100 m @ 1 kHz

Nominal Velocity of Propagation (NVP)

65 %

Operating Frequency, maximum

350 MHz

Operating Voltage, maximum

80 V

Remote Powering

Fully complies with the recommendations set forth by IEEE 802.3bt (Type 4) for the safe delivery of power over LAN cable when installed according to ISO/IEC 14763-2, CENELEC EN 50174-1, CENELEC EN 50174-2 or TIA TSB-184-A

Safety Voltage Rating

300 V

Electrical Cable Performance

CS

CommScope

Std

Refers to the standard value listed under Transmission Standards in the Electrical Specifications above

Typ

Typical

IL

Insertion Loss (dB/100m)

NEXT

Near End Crosstalk (dB/100m)

ACR

Attenuation to Crosstalk Ratio (dB/100m))

PSNEXT

Power Sum Near End Crosstalk (db/100m)

PSACR

Power Sum Attenuation to Crosstalk Ratio (dB/100m)

ACRF

Attenuation to Crosstalk Ratio - Far End (dB/100m)

PSACRF

Insertion Loss (dB/100m)

RL

Return Loss (dB)

Frequency

IL, CS

IL, STD

IL, TYP

NEXT, CS

NEXT, STD

NEXT, TYP

ACR, CS

ACR, STD

ACR, TYP

PSNEXT, CS

PSNEXT, STD

PSNEXT, TYP

PSACR, CS

PSACR, STD

PSACR, TYP

ACRF, CS

ACRF, STD

ACRF, TYP

PSACRF, CS

PSACRF, STD

PSACRF, TYP

RL, CS

RL, STD

RL, TYP

1.00 MHz

2.0

2.0

1.8

70.3

65.3

87.9

68.3

63.3

86.1

68.3

62.3

86.0

66.3

60.3

84.2

67.8

63.8

81.0

65.0

60.8

79.8

20.0

20.0

31.5

4.00 MHz

3.9

4.1

3.5

61.3

56.3

79.0

57.3

52.2

75.5

59.3

53.3

77.0

55.3

49.2

73.4

55.8

51.8

69.0

53.8

48.8

67.9

23.3

23.0

29.8

8.00 MHz

5.6

5.8

5.0

56.8

51.8

74.0

51.2

46.0

69.0

54.8

48.8

72.0

49.2

43.0

67.0

49.7

45.7

62.8

47.7

42.7

61.7

25.0

24.5

32.8

10.00 MHz

6.2

6.5

5.6

55.3

50.3

72.5

49.1

43.8

66.9

53.3

47.3

70.7

47.1

40.8

65.1

47.8

43.8

60.9

45.8

40.8

59.8

25.5

25.0

34.3

16.00 MHz

7.9

8.2

7.1

52.2

47.2

69.8

44.3

39.0

62.8

50.2

44.2

67.7

42.3

36.0

60.6

43.7

39.7

56.8

41.7

36.7

55.7

25.5

25.0

37.4

20.00 MHz

8.9

9.3

7.9

50.8

45.8

68.4

41.9

36.5

60.5

48.8

42.8

66.2

39.9

33.5

58.3

41.8

37.8

54.9

39.8

34.8

53.7

25.5

25.0

38.1

25.00 MHz

10.0

10.4

8.9

49.3

44.3

67.4

39.3

33.9

58.5

47.3

41.3

65.3

37.3

30.9

56.4

39.8

35.8

52.9

37.8

32.8

51.7

24.8

24.3

37.2

31.25 MHz

11.3

11.7

9.9

47.9

42.9

66.2

36.6

31.2

56.3

45.9

39.9

64.2

34.6

28.2

54.2

37.9

33.9

50.9

35.9

30.9

49.7

24.1

23.6

34.4

62.50 MHz

16.3

17.0

14.2

43.4

38.4

62.3

27.1

21.4

48.1

41.4

35.4

60.2

25.1

18.4

46.0

31.9

27.9

44.5

29.9

24.9

43.3

22.0

21.5

30.7

100.00 MHz

21.0

22.0

18.1

40.3

35.3

59.6

19.3

13.3

41.5

38.3

32.3

57.3

17.3

10.3

39.1

27.8

23.8

39.8

25.8

20.8

38.7

20.6

20.1

27.7

155.00 MHz

26.8

22.8

37.4

55.8

10.7

33.0

35.4

53.9

8.7

31.1

24.0

36.2

22.0

34.8

19.3

24.8

200.00 MHz

30.9

26.1

35.8

54.7

4.9

28.6

33.8

52.3

2.9

26.2

21.8

33.5

19.8

32.3

18.5

24.0

250.00 MHz

35.0

29.3

34.3

53.1

-0.7

23.7

32.3

50.9

-2.7

21.6

19.8

31.8

17.8

30.5

17.8

23.5

300.00 MHz

38.9

32.2

33.1

50.4

-5.8

18.1

31.1

48.3

-7.8

16.1

18.3

30.5

16.3

29.2

17.3

23.8

350.00 MHz

42.6

35.0

32.1

48.7

-10.4

13.6

30.1

46.7

-12.4

11.7

16.9

28.6

14.9

27.2

16.8

24.8

Material Specifications

Conductor Material

Bare copper

Insulation Material

Polyolefin

Jacket Material

PE

Mechanical Specifications

Pulling Tension, maximum

11.34 kg | 25 lb

Environmental Specifications

Installation temperature

-30 °C to +70 °C (-22 °F to +158 °F)

Operating Temperature

-40 °C to +70 °C (-40 °F to +158 °F)

Environmental Note

UV resistant for outdoor and/or direct burial installations

Environmental Space

Buried

Packaging and Weights

Cable weight

41.118 kg/km | 27.63 lb/kft

Packaging Type

Reel

Regulatory Compliance/Certifications

Agency

Classification

ISO 9001:2015 

Designed, manufactured and/or distributed under this quality management system

ROHS

Compliant

CHINA-ROHS 

Below maximum concentration value

REACH-SVHC

Compliant as per SVHC revision on www.commscope.com/ProductCompliance

UK-ROHS

Compliant