White Rodger Furnace Fan Control 50A65-5165 for Trane CNT03076 CNT03798 CNT05164
White Rodgers part number 50A65-5165 Direct Replacement for Trane Single Stage Integrated Furnace.
Replacement for Trane Numbers D341213P01, D341396P01, D341396P04, D341396P03, D341396P05, CNT03076, CNT05164, CNT03798, CNT05165.
White Rodgers Numbers 50A65-474, 50A65-475, 50A65-476, 50A65-5165.
The 50A65-5165 is an automatic gas interrupted ignition control that employs a microprocessor to continually monitor, analyze, and control the proper operation of the gas burner, inducer, and fan. Signals interpreted during continual surveillance of the thermostat and flame sensing element initiate automatic ignition of the burner, sensing of the flame, and system shut-off during normal operation. These controls incorporates system fault analysis for quick gas flow shut-off, coupled with automatic ignition retry upon sensing a fault correction.
- Pre-Purge 0 seconds
- Ignitor Warm-up 20 seconds
- Trial for Ignition Period 5 seconds
- Ignition Activation Period 2 seconds
- Retries 2 times
- Valve Sequence Period 15 seconds
- Interpurge 60 seconds
- Post-Purge 5 seconds
- Lockout Time 300 seconds
- Heat Delay-To-Fan-On 45 seconds
- Heat Delay-To-Fan-Off* 60/100/140/180 seconds
- Cool Delay-To-Fan-On 2 seconds
- Cool Delay-To-Fan-Off* 0/80 seconds
- Humidifier Yes
- Electronic Air Cleaner Yes Auto Reset Purge 15 seconds
*These times will vary depending on option switch position. The control is factory-set at 80 sec. cool delay-to-fan-off and 180 sec. heat delay-to-fan-off.
Product Details
Brand | White Rodgers |
---|
Manufacturer | White Rodgers |
---|
Product Type | Fan Control Board |
---|
Mpn | 50A65-5165 |
---|
- White Rodgers part number 50A65-5165
- Direct Replacement for Trane
- Single Stage Integrated Furnaces
- Replaces numbers CNT03076, CNT03798, CNT05164
Check out my other items.
-