02未标题-1ygi.jpg

 

Wall Mounted Ultrasonic Flow Meter with High TempTransducer TM-1-HT DN50-700mm

 

 Note:

This flow meter comes with High Temp Transducer TM-1-HT Medium Clip ,size: 64*39*44mm

for Pipe Diameter DN50 to 700mm, Temperature : -30~160°C

 

If you want to know other types Transducer,please see the parameters in upper picture. And contact us

 

Main Unit:

Principle: transit-time ultrasonic flowmeter

 Accuracy: +/-1%

 Display: 2x20 character LCD with backlight, support the language of Chinese, English, Italy, Turkish

 Signal output:

1)1way 4-20mA output, electric resistance 0-1K, accuracy0.1%

2)1 way OCT pulse output(Pulse width-1000ms, default is 200ms)

3)1 way Relay output

 

Signal input:

1)3 way 4-20mA input, accuracy 0.1%, acquisition signal such as temperature, press and liquid level

2)Connect the temperature transducer P100, can finish the heat/energy measurement.

3)Insulate Rs485 serial interface, upgrade the flowmeter software by computer, support the MODBUS.

 

Special Cable:Twisted-pair cable, generally, the length under 50 meters, select the Rs485, transmission distance can over 1000m

 

Pipe Installation Condition:

1)Pipe material:Steel, stainless steel, cast iron, copper, cement pipe, PVC, Aluminum, glass steel product, liner is allowed

2)Pipe diameter:25-6000mm

3)Straight pipe:Transducer installation should be satisfied: upstream10D, downstream5D, 30D from the pump.

 

Measuring Medium:

Type of liquid:Single liquid can transmit sound wave; such as water (hot water ,chilled water, city water, sea water, waste water, etc); sewage with small particle con tent, oil(curde oil, lubricating oil, diesel oil, fuel oil, etc); chemicals(alcohol, etc); plant effluent; beverage; Ultra-pure liquids, etc

Temperature:-30-160

Turbidity:No more than 10000ppm and less bubble

Flow rate:0-±7m/s

Temperature:Convertor; -20-60; Flow Transducer: -30-160

Humidity:Convertor: 855RH; Flow Transducer: can measure under water, water depth2m

 

Working Environment:

1)TemperatureConvertor; -20-60; Flow Transducer: -30-160

2)Humidity:Convertor: 855RH; Flow Transducer: can measure under water, water depth2m

 

Power Consumption:1.5W

 

Dimension:132*150*85mm(convertor)

 

Standard Packing:TUF-2000B Host,Steel Belt,TM-1-HT Ultrasonic Transducer,2 x 5m Flow Signal Cable

Optional Accessories:Other Transducer,if you need,please contact me.