5V - 24V Vorwärts/Rückwärts Motor-Steuerung Timing Delay Zeit Relais Platine Neu
Features:
Port:
Specification: Power supply: DC 6.5-25V, DC 5V Working current: 83mA Standby current: 41mA Relay load current: <5A Delay time: 0.1-999.9 seconds, 1-9999 seconds, 1-9999 minutes
Size: 8*5cm/3.2*2in Trigger mode: 1 low pulse trigger (falling edge trigger) 2 low level trigger (rising edge trigger)
Timer: T1: Forward timer T2: Reverse timer T3: Stop timer Time unit : 0.1 second, 1 second, 1 minute
Relay action: Motor forward : Relay 1 is ON, relay 2 is OFF, and the F LED indicator is flashing. Motor reverse : Relay 1 is OFF, relay 2 is ON, and the R LED indicator is flashing.. Motor stop : Relay 1 is OFF, relay 2 is OFF, and the S LED indicator is flashing.
Factory settings: Press the "++" and "--" buttons simultaneously for 5 seconds.
Energy-saving mode: Press and hold the "OK" button for 5 seconds to enter the "Energy-saving mode". Press and hold the "OK" button again for 5 seconds to exit the "Energy-saving mode". Energy saving mode just turns off the digital tube and LED indicator, and other functions are normal.
Function mode: F-01 After power-on, the motor is forward T1 time; then the motor stops T3 time; then the motor reverse T2 time; so it is repeated Nx times. When the STOP port is triggered, the motor stops working immediately. (FWD, REV port is invalid)
F-02 This function is a F-01 variant. F-01 is run directly after power-on, but F-02 needs to trigger FWD or REV port to run.
F-11(Trigger reversible 1) Trigger the FWD port, the motor is forward T1 time, and automatically stops (in order to the motor, during the delay period, trigger the REV port to stop T3 time and then reverse T2 time, trigger FWD port to re-time T1). Trigger the REV port, the motor is reverse T2 time, and automatically stops (in order to the motor, during the delay period, the FWD port is triggered to stop the T3 time and then the T1 time is forward, and the REV port is re-timed T2). When the STOP port is triggered, the motor stops immediately, regardless of whether the motor is forward or reverse.
F-12(Trigger reversible 2) Trigger the FWD port, the motor is forward T1 time and stops automatically (during the delay period, except for triggering STOP port, the other ports are invalid). Trigger the REV port, the motor is reverses T2 time, and automatically stops (during the delay period, except for triggering STOP port, the other ports are invalid). When the STOP port is trigger, the motor stops immediately, regardless of whether the motor is forward or reverse.
F-21 When the FWD port is low level, the motor is forward, and after the FWD port is released, the motor stops. When the REV port is low level, the motor is reversed, and after the REV port is released, the motor stops. In this mode, the FWD and REV ports cannot be connected low level at the same time, and the STOP port is invalid.
F-22 When the FWD port is low level, the motor is forward, and after the FWD port is released, the motor stops.When the REV port is low level, the motor is reversed, and after the REV port is released, the motor stops. In this mode, the FWD and REV ports cannot be connected low level at the same time, triggering the STOP port, the motor stops immediately.
Parameter setting: There are three menus: Work Menu, Function Menu, Parameter Menu. Note: When entering the "Function Menu" or "Parameter Menu", the module still works normally (countdown and the trigger is running normally). The set parameters are valid only after being powered on again.
1 Power on to enter the running state (Work Menu). If the current function is F-01, then the motor direct run and the digital tube displays the countdown. F-01 is displayed after the operation is completed. If the current function is other functions, such as F-11. Then the digital tube displays F-11. After the trigger, the digital tube displays the countdown. After the operation is completed, F-11 is displayed.
Package list: 1 x Motor Controller board
|