Main
range of product
OsiSense XC
series name
Standard format
product or component type
Limit switch
device short name
XCMD
sensor design
Miniature
body type
Fixed
head type
Plunger head
material
Metal
body material
Zamak
head material
Zamak
fixing mode
By the body
movement of operating head
Linear
type of operator
Spring return plunger metal
type of approach
Vertical approach, 1 direction
number of poles
2
contacts type and composition
1 NC + 1 NO
contact operation
Snap action
Complementary
switch actuation
On end
electrical connection
Removable cable connector
cable length
3.28 ft (1 m)
cable composition
5 x 0.75 mm²
wire insulation material
PvR
contacts insulation form
Zb
positive opening
With
positive opening minimum force
42.5 N
minimum force for tripping
8.5 N
minimum actuation speed
0.01 m/min
maximum actuation speed
1.64 ft/s (0.5 m/s)
contact code designation
B300, AC-15 (Ue = 240 V), Ie = 1.5 A EN/IEC 60947-5-1 appendix A
R300, DC-13 (Ue = 250 V), Ie = 0.1 A EN/IEC 60947-5-1 appendix A
[Ui] rated insulation voltage
300 V 3)UL 508
400 V 3)IEC 60947-5-1
300 V 3)CSA C22.2 No 14
maximum resistance across terminals
25 mOhm IEC 60255-7 category 3
[Uimp] rated impulse withstand voltage
4 kV IEC 60664
4 kV IEC 60947-1
short-circuit protection
6 A cartridge fuse gG
electrical durability
5000000 cycles, DC-13, 120 V, 1 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C
5000000 cycles, DC-13, 24 V, 3 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C
5000000 cycles, DC-13, 48 V, 2 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C
mechanical durability
10000000 cycles
width
1.18 in (30 mm)
height
1.97 in (50 mm)
depth
0.63 in (16 mm)
net weight
0.40 lb(US) (0.18 kg)
Environment
shock resistance
25 gn 18 ms IEC 60068-2-27
vibration resistance
5 gn 10…500 Hz)IEC 60068-2-6
IP degree of protection
IP66 IEC 60529
IP67 IEC 60529
IP68 IEC 60529
IK degree of protection
IK06 EN 62262
overvoltage category
Class I IEC 61140
Class I NF C 20-030
ambient air temperature for operation
-13…158 °F (-25…70 °C)
ambient air temperature for storage
-40…158 °F (-40…70 °C)
protective treatment
TC
product certifications
CSA
UL
CCC
standards
UL 508
EN/IEC 60204-1
CSA C22.2 No 14
EN/IEC 60947-5-1