Industrial H2S Gas Monitor Fixed Hydrogen Sulfide Detector Sound Light Alarm

 

Introduction:

  • Fixed gas detector adopts advanced catalytic gas sensor or electrochemical sensor, which can translate the gas concentration in the air to the digital signal output. 
  • The detector working with gas controller can be used to detect gas in refinery, chemical plant, LPG station, boiler room, painting plant and other places with gas exists.

Specifications:

Product type

fixed gas detector/transmitter

Explosion proof grade

Exd ⅡC T6 Gb

Response time

≦30S

Power supply

DC24V±10%

Working temperature

-20℃50℃

Output current

4-20mA

Working humidity

0-95%RH

Contact output

Free contact output, max power 1kW

Single input

4~20mA and RS485

Installation method

Wall-mounted

Shell material

Aluminum

Dimensions

190x150x95mmL×W×H

Specifications:

Model

Range

Resolution

L-alarm

H-alarm

H2S

0-100ppm

0.1ppm

10ppm

20ppm

CO

0-1000ppm

1ppm

50ppm

150ppm

O2

0-30%vol

0.1%vol

19.5%vol

23.5%vol

H2

0-1000ppm

1ppm

50ppm

150ppm

CH4

0-100%LEL

1%lel

20%LEL

50%LEL

C2H4O

0-100ppm

1/0.1ppm

20ppm

50ppm

EX

0-100%LEL

1%lel/1%vol

20%LEL

50%LEL

C3H8

0-100%LEL

1%lel/1%vol

20%LEL

50%LEL

C2H5OH

0-100%LEL

1%lel/1%vol

20%LEL

50%LEL

NH3

0-100ppm

0.1/1ppm

20ppm

50ppm

CL2

0-20ppm

0.1ppm

5ppm

10ppm

O3

0-10ppm

0.1ppm

2ppm

5ppm

SO2

0-20ppm

0.1/1ppm

5ppm

10ppm

PH3

0-20ppm

0.1ppm

5ppm

10ppm

CO2

0-5000ppm

1ppm/0.1%vol

1000ppm

2000ppm

NO

0-250ppm

1ppm

50ppm

150ppm

NO2

0-20ppm

0.1ppm

5ppm

10ppm

HCN

0-50ppm

0.1/0.01ppm

10ppm

20ppm

HCL

0-20ppm

0.001/0.1ppm

5ppm

10ppm

CH2O

0-20ppm

1/0.1ppm

5ppm

10ppm

HF

0-100ppm

0.01/0.1ppm

2ppm

5ppm

C7H8/C8H10

0-20ppm

0.01/0.1ppm

5ppm

10ppm