WIRING:
PIN1: Start (+12v)
PIN2: Diagnostic, as Wbus heater (!)
PIN3: Start (+12v)
PIN4: Interior fan controlling (switch on at 40°C)
PIN5: Not used
PIN6: Fuel pump
*
If the coolant temperature reaches 76°C, heating power reduces to ~50% capacity.
If the coolant temperature gets lower than 56°C, the capacity rises up to 100%.
The heater will switch off, if the coolant temperature reaches 80°C .
Starts on 12V start signal and works until the coolant temperature reaches 80°C or detects any operational problem.
Voltage tolerance: 10V minimum (10 sec), 15,5V maximum (3sec)
Standby current <2mA (in sleep mode)
It has all safety control functions (for example: flame monitoring, checking of continuous ventillating, temperature monitoring and so on).
Universal, so it does not start from Wbus. Wbus PIN (PIN2) is restricted for diagnostic only! If you use Telestart (T91.example), 1533 "oval" timer -> use the analog output, and connect to the PIN1 on my board)!
You could start it with any external timer, RF remote (for example Telestart) or a control panel which gives more than 10V continuously (any switch or timer) for starting.
Attending documentation contains all of the information you need to diagnostic, outfit, stripping (PDF-EMAIL).
We grant 2 years of warranty.
Warranty void in case of liquid damage (fuel, water, etc.) or visible repair attempt.
Questions will be answered ASAP. Sorry, we speak english and hungarian only.
PayPal and IBAN transfer accepted.
Shipping expenses (with charging) is assumed to the buyer, but we always serve by the lowest possible postage prices.
Returns & Exchange policy:
Product must be sent back in the same condition as received. Broken, damaged, dirty, painted, wet or oxidized by coolant, water or fuel: no returns accepted! In this case: NO refund!
RETURNS and/or REFUND IS NOT APPLICABLE, until you do not send screenshots, video or information from the WEBASTO THERMO TEST SOFTWARE about the heater's working parameters and/or fault list!
No refund applicable, if you do not contact me before ship back the item.
The seller is not responsible for the technical incompetence of the buyer!
Product must be returned within 15 days for REPLACEMENT.
Return shipping costs must be paid by the buyer, no exclusion.