2pcs VU meter DB level header audio power amplifier chassis backlight TN90 with 1pc TS-VU003 drive board

Description:

Pointer material: zinc and copper nickel alloy.

Pointer color: red

The direction of the pointer swing: from left to right

Pointer length: 44 ± 1 mm from the center axis to the end of the needle

Width of the pointer: 0.45 ± 0.05 mm


Electrical characteristics:

Standard test conditions temperature: 20 ° C, humidity 70%. Can also be tested under normal temperature and humidity conditions.

The influenza degree pointer on the zero scale to the maximum scale sensitivity of 960uA ± 8% (full scale position).

Internal impedance: 650Ω ± 10%.

Isolation impedance meter outside the box plus the electrical circuit with 500V DC plus 50M ohm meter shell.

The electrical circuit impedance isolation is 500V DC test the isolation value. Pointer overlaps with the zero scale tolerance of ± 1mm of the symmetrical meter with a standard position and 90° tilt to allow the error range of ± 1mm

Pointer to mount the current time plus three times the full scale current, and slowly reduced to the electrical influenza degree 1/2 reading,

Pointer again to the scale plate within a friction meter of 1/3 coupled with the current, and slowly increases or decreases to a certain value, the error range of ± 1 mm.

Brake immediately plus scale plate 2/3 of the current value of the pointer indicates the position of the time required for one second or less.


Special test:

Tests at each interval of five seconds to ten times the full overload of the current input, the action is repeated nine times for each time of 0.5 seconds. After this test 7-14 to remain normal.

Vibration meter packed in the vibration plate 1,000 times per minute, up and down 4mm shock in each direction for 10 minutes. After this test 7-14 to normal impact test meter packed 30-cm height of the fall in 3cm thick wooden board, XYZ three-directional test.After this test 7-14 to maintain normal reliability test the current input of 100,000 calibration points within the limits of the current sense is still the standard environmental compatibility test temperature of 50 ° C, humidity 85%, for 100 hours, after this test 7-14 to maintain normal.

Terminal pull test: terminals must withstand one kilogram of tension, sustained 60 seconds will not be affected.


Other:

Temperature limits for use: -10 ° C to +60 ° C RH 35 to 85%.

Temperature limits for storage: -20 ° C to +60 ° C RH 35 to 85%.

 ----- Do not use the meter in direct sunlight and place the meter in the box to avoid foreign objects inside the meter.

Soldering condition terminal placed about 3 mm in the temperature of 230 ° C tinplate 3.5 seconds.

After this test, 7-14 to hold normal,

Manual soldering gun to solder temperature 350 ° C, the terminal contact for 3.5 seconds, the terminal front end of about 3 mm contact with the soldering gun.

After this test, 7-14 to hold normal,

Anti-static test in the same direction three times to mark the difference between the pointer in the length of the scale in a transparent cover surface to dry nylon 1/3 back to the zero position.

Light bulb specifications: weak yellow neon tube 12V.

We have TA-7318P original VU meter driver board for this VU meter in stock.


Package:


2pcs VU meter level audio power amplifier chassis backlight Denon.

1pc TS-VU003 drive board(This driver board can be directly connected to the output of the amplifier, the output voltage is adjustable, so the connection with the backlight level meter can not add resistance, more convenient).