AUTOOL LM120 is an auxiliary instrument for the installation,testing and maintenance of refrigeration equipment such as air conditioners and cold storage.The instrument has double pressure test, dual temperature test (need test clip,not include), digital readout,multi-unit switching, multi-mode function and built-in refrigerant database.
AUTOOL LM120 uses high-strength engineering plastics and flexible non-slip silicone design, the whole machine is solid and comfortable to hold. Built-in 32-bit digital processing unit and high-precision data acquisition unit, high data and stability.Large-size liquid crystal display, LCD backlight support, data display clear and easy to read, convenient light operation.Long-life valve switch, 1/4-inch standard interface design to ensure that the instrument's durability and versatility.
AUTOOL LM120 can measure double pressure (gauge pressure) at the same time, as well as dual temperature measurement (need test clip,not include), with automatic multi-unit pressure conversion, automatic conversion of temperature Celsius / Fahrenheit, to facilitate different needs.Built-in 89 kinds of refrigerant pressure-evaporation temperature database, also calculate the subcooling superheat, to facilitate direct reading of operating process data.Also it tests percentage of vacuum measurement; pressure leak measurement, leak time speed record.It is deserved to have this multi-functional, accurate and simply operated digital manifold let you do the job right.
Main Function:
1. [Evaporation Pressure & Tempe test]: The maximum pressure when the refrigerant changes from liquid to gas. The lowest temp when the liquid becomes gaseous.(The lower the pressure and temp of the evaporation are, the more efficient the refrigeration cycle and the greater the refrigeration capacity will do.)
2. [Condensing Pressure & Temp Test]: The minimum pressure when the refrigerant changes from gas to liquid, and the maximum temp when the gas changes to liquid. (The lower the pressure and temp of condensation are, the higher the efficiency of the refrigeration cycle and the greater the refrigerant capacity will do.)
3. [High/Low-pressure temperature test]: The temperature of the AUTOOL LM120 digital refrigeration manifold in the high/low-pressure pipelines of the air conditioning system.
4. [Pressure leakage test]: Calculate the pressure difference between the initial test pressure and the second test pressure to determine if the refrigerant is leaking.
5.[Type Setting & Observable window]: AUTOOL LM120 digital refrigeration manifold can be set according to the type of refrigerant that the car needs to fill; The refrigerant filing status can be observed through a visible window.
6.[Smart Digital Display]: The intelligent digital display of the test results of the pressure and temperature of the air conditioning system reduces the cost of time.
Specification:
Pressure test: gauge pressure
Pressure test unit: Kpa; Mpa; bar; inHg; PSI.
Pressure test range: 0 Kpa – 6000 Kpa
Pressure test resolution: 1 Kpa
Pressure test accuracy: +/- 0.5 %(FS)+ 5dgt
Pressure overload limit: 10000 Kpa (10 Mpa; 100 bar;)
Vacuum test: relative vacuum
Vacuum test unit: Kpa; Mpa; bar; inHg; PSI.
Vacuum test range: -101 Kpa – 0 Kpa
Vacuum test resolution: 1 Kpa
Temperature test unit: °C (Celsius), °F (Fahrenheit)
Temperature test range: -40°C–150°C (-40°F–302°F)
Temperature test resolution:
0.1°C (-40°C–99.9°C), 1°C (100°C–150°C)
0.1°F (-40°F–99.9°F), 1°F (100°F–302°F)
Temperature test accuracy: +/- 0.5 °C + 2dgt +/- 0.9 °F + 2dgt
Built-in 89 kinds of refrigerant NIST: According to American NIST standard
Power Supply: 4 X 1.5V (SIZE.AA / LR6) Battery not included
EC/EN61010-1 safety standards for design and production.1) The pressure measured by the digtal manifold pressure tester is gauge pressure.2) Pressure testing ranges from -101Kpa to 6Mpa (-0.1bar to 60bar).3) The limit pressure is 10 Mpa (100 bar).4) The maximum operating pressure of standard hose is 600 PSI ( approximate 4.13 Mpa, 41.3 bar ).The limit pressure is 3000 PSI approximate 20.68 Mpa, 206.8 bar ).5) Please confirm the rated pressure value of the tested equipment before testing.Do not use it if it exceeds the range of the instrument. Also for DY517A, if the packedhoses does not match the pressure requirement, you can use suitable replacements for testing.6) Do not use and store the instrument in high temperature, high humidity, flammable, explosive and strong electromagnetic fields.7) Please do not change the instrument internal circuit, to avoid any damage of the instrument or danger occurring.8) Please wear qualified protective equipment to protect user during testing.9) Please use the instrument in a well-ventilated environment to prevent inhalation of toxic gases. Package Include:
1x refrigerantion digital manifold gauge
1x User manual (English)
Note: This manifold gauge does not come with clips and three hoses.