electrocardiograma ECG machine E3M

               
Introduction
E3M is a kind of electrocardiograph, which is able to sample 12 leads ECG signals simultaneously and print out the ECG waveform with thermal printing system. Its functions are as follows: recording and displaying ECG waveform in auto/manual mode; measuring ECG waveform parameters automatically, and automatic analysis and diagnosis; pacing ECG detection; prompt for electrode-off and out of paper; optional interface languages(Chinese/English, etc.); built-in lithium battery, powered either by AC or DC; arbitrarily select the rhythm lead to conveniently observe abnormal heart rate; case database management, etc.

Function
1)Sync collection for 12-lead ECG, adopt digital signal processing technology and get high-quality ECG waveform via power frequency filter, baseline filter and EMG filter of ECG signal.
2)Display of 1/3/6/12-lead ECG, print mode, sensitivity, paper speed and filter state, etc. on one screen, convenient for contrastively diagnosing.
3)Multiply printing modes and formats, including manual, auto 4x3, auto 3x4+1, auto 3x4, auto 2x6+1, auto 2x6, etc. Waveform length printed can be adjusted, and with timed print function, which meets different requirements.
4)With the functions of auto-analysis and auto-diagnosis for routine ECG parameters, which reduces the doctor’s burden.
5)Build-in memory, which is convenient for doctor to review case and statistic.
6)Multi- language(Chinese, English) interface and report.
7)Optional ECG-Sync software, connect with PC by USB2.0 interface to form a ECG workstation, import real-time data to the software for analyzing and report printing, and old cases stored in Electrocardiograph can be uploaded to PC.
8)Power supply: AC/DC and built-in rechargeable lithium battery, which meets the requirements of visiting a patient at home and body examination.

Performance
Input way: Floating and defibrillation protection
Lead: Standard 12 leads
Patient leakage current: <10µA
Input impedance: ≥100MΩ(1Hz)
Frequency response:0.01~150 Hz(-3 dB)
Time constant: ≥3.2s
CMRR: >123 dB
Filter: power frequency(AC50/60 Hz), myoelectricity(25 Hz/35 Hz (-3 dB)), baseline drift filter
Recording way: Thermal printing system
Specification of recording paper: 80 mm(W)×20 m(L) high-speed thermal paper
Time base selection(paper speed):6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s, error: ±5%
Gain control(sensitivity): 2.5, 5, 10, 20 mm/mV, accuracy is ±2%; Standard sensitivity: 10 mm/mV±0.2 mm/mV
Auto record: record setup according to auto record format and mode, automatically change leads, automatically measure and analyze.
Rhythm record: record setup according to rhythm record format and mode, automatically measure and analyze.
Manual record: record according to manual record format.
Measurement parameters: HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5) amplitude, S(V1) amplitude, R(V5)+S(V1) amplitude
Product safety type: Class I type CF defibrillation-proof applied part
Polarization resistance voltage: ±950mV
Noise level: ≤12 µVp-p
ECG signal input sampling frequency: 32 kHz
Waveform data processing sampling frequency: 1 kHz
Sampling precision: 24-bit
The minimum detection signal: 10 Hz, 20 µV(peak-peak value) deflected sinusoidal signal can be detected
Accuracy of input signal: ±5 %
Amplitude quantization: ≤5µV/LSB
Interchannel time deviation: <100 µs
Calibration voltage:1 mV±2 %
Input circuit current:≤0.01 uA
50Hz interference suppression filter:≥20 dB
Pacing detection channel: all leads
Power supply: 
AC: 100V~240V(50/60Hz)
DC: 7.4V/5000mAh rechargeable lithium battery
Degree of protection against ingress of liquid: IPX0
Working mode: continuous working

Accessories
Standard configuration:
A lead cable
A limb electrode
A chest electrode
A thermal recording paper
A power cord
An earth wire
A user manual

Physical characteristic
Working environment
Temperature: 5℃~40℃
Relative humidity: 25%~95%(non-condensing)
Atmospheric pressure: 700 hPa~1060 hPa
Transport and storage environment
Temperature: -20 ℃~+55 ℃
Relative humidity: ≤95%
Atmospheric pressure: 500 hPa~1060 hPa
Dimension: 315mm(L)×200mm(W)×77mm(H)
Net weight: 1.5Kg


Buy safe products

The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE: The sale of this item may be  subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If the item is subject to FDA  regulation, we will verify your status as an authorized purchaser of  this item before shipping of the item.

The Fingertip Pulse  Oximeter is registered on the Australian Register of Therapeutic Goods  (ARTG)with the code 197923, and certified by FDA of United States and  CE,TUV of Europe. The  Fingertip Pulse Oximeter that is FDA 510K  Approved

International Buyer--Please note:

Import duties,Taxes are not included in the item price.These charges are buyers' responsibility

Agent in the world!
We are looking for partners in the world now!

Do you want  to become our agent in you conutry?

Join US!

Skype:xuebox3

contec.med.mary at hotmail.com

               
           
       
       
   

Only English User Manual,Please contact us if you need other language version.thank youibay365