Three Phase Power Quality Analyzer Meter 3 phase Power Energy Meter Analyzer


Features:

ETCR5000 Power Quality Analyzer's Basic Function:

1. Transient capture function

2. Starting current monitoring

3. Trend chart recording and storing function

4. Alarm function

5. Snapshot function

6. Communication function

7. Setting function

8. Help menu in Chinese/English

Specification:

Power Supply

Rechargeable lithium battery pack 9.6V, external charger.

Battery indicator

Battery symbol 5 grid Show the power, when the battery power is too low, prompted 1 minutes after the automatic shutdown.

Working current

Current 490mA, the battery is full of electricity for about 8 hours of continuous work.

display mode

LCD Color screen, 640dots * 480dots, 5.6 inch display domain 116mm * 88mm.

Clamp size

008B: φ8mm; 040B: φ40mm; 068B: φ68mm; 300F: φ300mm

Instrument size

240mm*170mm*68 mm.

Total Weight

6KG

Channel number

4-CH voltage, 4-CH current.

Line voltage

1.0V~2000V.

Phase voltage

1.0V~1000V.

Electric current

008B/040B/068B/300F Current clamp

frequency

40Hz~70Hz.

Electric quantity parameter

W, VA, Var, PF, DPF, cosφ, Tanφ

Electric energy parameters

Wh, Varh, Vah.

Harmonic

Yes, 0~50 times.

Total harmonic distortion

Yes, 0~50 times, each phase.

Expert mode

Yes.

Transient recording

150 Groups.

Voltage flicker

Yes.

Starting current mode

Yes, 100 seconds.

Three-phase unbalance degree

Yes.

Record

300Day (record 20 parameters simultaneously, 1 points per 5 seconds).

Min / Max

Record value

There are, can be measured for a period of time the maximum and minimum value.

Give an alarm

40Different types of parameter selection, 12800 groups of alarm log.

Peak value

Yes

Phasor diagram display

Automatically.

Screenshot capacity

60A.

Menu language

English and chinese.

Communication interface

USB

Automatic shutdown

In the alarm / trend chart recording / transient capture mode (waiting or in the middle), the instrument does not automatically shut down.

In other test mode, no button operation within 15 minutes, 1 minutes after the automatic shutdown.

Backlight function

There is, for the dark places and at night.

Voltage test line

3m

Current clamp length

2m

Working temperature and humidity

-10C~ 40 degrees C; 80%Rh below.

Storage temperature and humidity

-10C~ 60 degrees C; 70%Rh below.

Input impedance

The input impedance of the test voltage is 1M.

Pressure

The instrument circuit and the outer shell withstand 3700V/50Hz sine wave alternating current voltage for 1 minutes.

insulation

Between the instrument line and the jacket shell is larger than 10M.

structure

Double insulation with anti-insulation vibration jacket.

Safely Standard

IEC 61010 1000V Cat III / 600V CAT IV, IEC61010-031, IEC61326, Pollution degree: 2.

Accessories

Host: 1PCS; Instrument Bag: 1pcs; Test Cable: 5PCS (yellow, green, red, blue, black); Alligator Clip: 5PCS; Probe: 5PCS; Charger 1PCS; Software CD: 1COPY; Optional Current Clamp: 4PCS

Parameters of current clamps:

Model

008B

040B

068B

300F

Function

AC current and leakage detection

Test model

Clamp CT, Current induction output

Clamp size

Φ8mm

Φ40mm

Φ68mm

Φ300mm

Current range

AC 10mA~10.0A

AC 0.1A~100A

AC1.0A~1000A

AC10A~6000A

Resolution

0.1mA

Accuracy

0.5% (23℃±3℃, below 70%RH)

Current transform

Around 1A/1mA

Circuit voltage

Lower than AC600V

Cable length

2m

Working environment

-20℃~50℃; below 80%RH

Storage environment

-10℃~60℃; below 70%RH

Weight

170gX4

190gX4

510gX4

 

Package: