MASTERCOOL Intellasense Refrigerant Leak Detector
The 55800 leak detector employs a new metal oxide gas sensor for the detection of chlorofluorocarbon gasses and blends. This tin oxide sensor is characterized by high sensitivity and a fast response, upon detecting the presence of extremely small levels of chlorofluorocarbon gases.
Integrated into the design is a powerful microprocessor that automatically selects the best operating conditions for the sensor, to ensure optimum performance. The optimum sensor performance is maintained and monitored throughout the life of the sensor.
Technical Features
- SENSITIVITY:
- HIGH ≥ 0.15 oz/yr (4.25 g/yr)
- MEDIUM ≥ 0.25 oz/yr (7 g/yr)
- LOW ≥ 0.5 oz/yr (14 g/yr)
- PROBE:
- Intelligent tip design that senses the condition of the environment, to eliminate the potential of false alarms.
- Flexible 16” probe for difficult to reach locations
- DISPLAY:
- Progressive LCD with vertical bars corresponding to the magnitude of the detected leak
- Visual indication of the selected sensitivity range
- REFRIGERANTS:
- Detects all refrigerants (CFC’s, HCFC’s, & HFC’s)
- Unit has been tested and approved to work with R1234yf as well as R32 and R410a
- SENSOR LIFE: 2000 hours
- OPERATING TEMPERATURE RANGE: 0 to 140˚F
- POWER: Two (2) D Batteries
- BATTERY LIFE: 60 hours continuous use
- WEIGHT: 1 lb. 8 oz
Please open the battery cover and remove the insulation sheet
Package Included
- 1 X LEAK TEST VIAL
- 1 X 2"D" BATTERIES
- 3 X REPLACEMENT FILTERS
- 1 X BLOW MOLDED PLASTIC BOX
- 1 X SENSOR PROTECTOR
Applicable to all halogen refrigerants, including but not limited to
- CFCs: Such as R12, R11, R500, R503
- HCFCs: Such as R22, R123, R124, R502
- HFCs: Such as R134a, R404a, R410a, R407C, R32
- HCs: Such as R600a, R290
- HFOs: Such as R1234YF
Trouble Guide
- The unit will not power up
- The unit powers up briefly then shuts OFF
- The unit alarms continuously without stopping
- E2 Code Appears on LCD
- E8 Code Appears on LCD
- E9 Code Appears on LCD
Parameters
- Sensor Type: Heated Tin Oxide Element
- Applicable refrigerant: CFC, HFC, HCFC and blends
- Minimum detectable leakage: ≥0.50 oz/yr (14 g/yr)
- Sensor lifetime: ≥2000 hours
- Reaction time: ≤1s
- Reset: Automatic/manual
- Warm-up time: 30s
- Probe length: 16.5 in/420mm
- Reset time: 10s
- Package size: 12.3oz/ 350g
- Working temperature range: 0-50℃
- Battery life: 7 hours
- Working Humidity Range: <80%RH (non-condensing)
- Weight: 17x9.6x27.5 in /430x245x700 mm
- Auto-off Time: 30 min