Kältemittel Leckdetektor Klimaanlage Klima Lecksuchgerät Halogen CFCs Leckfinder
 
Description:
This refrigerant leak detector hvac is designed to detect refrigerant leaks in automotive air conditioners, cold storage, refrigerant recovery devices and home, office, and industrial cooling/refrigeration systems. Freon leak detector can detect all halogen CFC, HFC, HCFC refrigerants, such as R22, R134a, R410a, R502, R12, R404a, R407, etc. It is an essential tool for technicians in the field of refrigeration and air conditioning services.
 
Feature:
Advanced Thermal Diode Sensor
This refrigerant leak detector uses the latest thermal diode sensor which is very sensitive to many kinds of halogen gases. And leak detector hvac adopts the newly designed circuit and advanced signal processing microprocessor, which can fast react and accurately detect tiny refrigerant leaks, and moisture will not cause false alarms.
 
Adjustable 3 Levels Sensitivity
The freon leak detector provides 3 levels of sensitivity for selection. When you press the sensitivity key, the 2 left LEDs light up green indicates low sensitivity level, the 2 right LEDs light up in red indicates high sensitivity level, the medium orange LEDs light up indicates medium sensitivity level. Adjust to the required sensitivity according to the detection environment, the measurement accuracy will be higher.
 
Environment Reset Function
After pressing "reset" button, freon leak detector will automatically set to ignore the refrigerant concentration on probe sensor, and will only alarm when the refrigerant concentration is higher than the current environment. This feature helps you efficiently track down higher-concentration leaks. (Note:The device automatically turns on the environment reset function by default when starting up. It is recommended to start up in fresh air without refrigerant leakage).
 
Tricolor LED Indicators & Buzzer Alarm & Low Battery Alarm
When refrigerant leak detector detects a leak point, the buzzer will sound an alarm, and LED indicators will light up from left to right, from green light (low concentration) to orange light, to red light (maximum concentration), indicating that the probe tip is close to the source of the leak. When the battery is close to its service life, red LED low battery power indicator will light up to remind you to replace battery or charge it.
 
15.5" Flexible Probe 
Stainless steel probe tube of leak detector is 15.5inch long and covered with rubber to prevent rust and corrosion. It can be bent at will, so the position of the leak can be easily accessed and detected even in difficult and hard-to-reach areas. 
 
2 Power Supply & Low Power Indicator
This refrigerant leak detector have two ways of providing power: 4 AA alkaline batteries(not include) or AC power adapter(include). You must know that the AC power adapter can only provide power directly to the hvac leak detector, not to charge the batteries. When the red "Lo BAT" Indicator light is on it means the battery is nearing the end of its life and needs to be replaced.
 
 
 
Operation Step:
1. Place the tip of the leak detector probe as close as possible to the site of the suspected leak. Try to position the probe within 1/4 inch (6 mm) from the possible leak source.
2. Slowly move the probe past each possible leakage point. When the instrument detects a leak, the audible tone will alarm, and the visual indicators will be lit from left to right, Green LED then change to orange LED, and then to red LED(highest concentration) as increasing levels of alarm, indicating the location is closer to the leaking source. When the instrument signals a leakage, pull the probe away from the leak for a moment, then bring it back to pinpoint the location.
3. If the refrigerant leak is large, setting the sensitivity switch to LOW will make it easier to find the exact site ofthe leak.
4. Return the sensitivity switch to HIGH before searching for additional leaks.
5. When you have flnished checking, tum OFF the instrument and store it in a clean and dry place,protect the leak detector from possible damage.
 
Note:
Refrigerant leak detectors are used to find very low level halogen refrigerant (cfc, hcfc, hfc) leaks. When the leak occurs in a closed room and the concentration of the leak is too high, do not use the leak detector, need to ventilate the closed space first. Refrigerant leak detectors cannot detect refrigeration systems that use refrigerants beyond halogens.
 
 
Specification:
Alarm Method: Sound and visual: Buzzer, Tricolor LED Indicator.
Power Supply: AC power adapter and/or 4 AA sized (6V DC) Alkaline Batteries.(battery not include)
Battery Life: Approximately 7 hours continuous normal usage.
Auto power OFF: 10 minutes
Disable Auto Power Off: Press and Hold "Hi" button and power button.
Warm-Up Time: Approximately 45 seconds
Operating Temperature & Humidity: 0~40 C,<80% RH
Storage Temperature & Humidity: -10~60 C,<70% RH
Altitude: <2000M (6500. )
Sensor Wand Length: 40cm (15.5 inches)
Physical Dimension: 173 x 66 x 56 mm
Weight: approximately 400g
 
Package included:
1pc * Refrigerant Leak Detector(battery not include)
1pc * AC Adapter: 110-240V AC
1pc * User manual
1pc * Carry case
 
 
 
1. We accept PayPal only.
2. Credit card (Visa, Eurocard/MasterCard, Amex, and Switch or Visa/Delta) payment can be accepted ONLY through PayPal.
3. Other payment methods (Bank transfer, Cheque, etc.) are NOT acceptable.
4. Please make the payment within 3 days.
1. We ship to WORLDWIDE .
2. Item will be shipped out within 1-2 working days (except weekends and holidays) after the payment is cleared or received.
3. We will send item to your Confirmed Shipping Address in Paypal only.Please confirm your order and address before you bid or pay the item.
4. International Buyers Please Note:
  1)Please check with your country customs office to determine what these additional costs will be prior to bidding / buying.      2)Import duties, taxes and charges are the buyer’s responsibility,please understand.
Item may be returned for refund or replacement within 30 days of the purchase date.
Defective products may be returned for repair up to 1 year from the purchase date. Repairs will be processed through the manufacturer, we will assist in the repair procedure in any way we can to expedite the process.
Before any return, a Return Merchandise Authorization (RMA) must be obtained by contacting the seller. Any products returned to us without an RMA will be sent back to the buyer at his/her expense. The buyer is responsible for the cost of returning any merchandise.
We are a professional worldwide Professional company.
We are reliable supplier to both wholesalers and retail sellers. We supply many products on Automobile consumer.Also offer reasonable prices , excellent customer service and a reliable credit standing are our target!
Our normal business hour is Monday to Friday 9:00 AM to 6:00 PM Beijing TIME. Please email me through "MY MESSAGES" on eBay, if you have any questions about our listings or inventory or troubles. All messages be reply within 24 hours. Welcome your any-time parchase!
PushAuction