QUALITY PRODUCT, NEW 


PANEL TIMER 

24V 


Specifications:
Product Name: Digital Display Time Relay
Power supply voltage: DC 24v
Interval selection: 0.01 second, 0.1 second, 1 second, 1 minute
Time range: minimum 0.01 second maximum 999 minutes
Product weight: CC 40g CA 50g
Opening size: 40mm * 74mm
Current: DC max 10A AC max 5A

Package Included:
1 * Time Delay Relay Module

-
User Guide:
This product has 4 buttons, plus button, minus button, setting button, stop or start button.
There are two time ranges T1 and T2 for users to set.

Precautions
1. All relay parameters are stored automatically in 5s,
2. If it is necessary to stop during operation, press the stop button to stop the relay and reset the data. Press the stop button again to activate again.
3. When the relay terminates normally, press the stop button to reactivate the start.

Time setting T1:
Directly press the plus or minus button to set T1, the data will be automatically stored 5s after setting and start timing.
Time setting T2:
Short press the setting button, the digital tube flashes, at this time, press the button to increase or decrease to set T2, 5 seconds after the completion of the setting, automatic memory starts to work.

Time range: Automatically change the range. The default interval is seconds. Decrease the number to 0, keep pressing the button to decrease, the interval will automatically change to 99.9s; add the number to 999, keep pressing the button to increase, the range will automatically change to 0.0.0

The format of the number is as follows
XXX --- time interval 0.01s
X XX --- time interval 0.1s
XXX X---time interval 1s
XXX---time interval 1min

For example: setting T1=8.88, the controller counts down 0.01s, T2=8,8,8, the controller counts down 1 minute.
Working Mode Setting: 6 working modes for users to set.
Long press the setting key to enter P-0 parameter, and set the required working mode by pressing the plus or minus key on the current interface.

P-0: The relay switches off after a delay of T1 and terminates
P-1: The relay closes after a time delay T1 and ends
P-2: The relay is closed after a delay of T1, then opened after a delay of T2 and terminates
P-3: The relay opens after a delay of time T1, then closes after a delay of time T2 and terminates
P-4: the relay is closed after a delay of time T1 and then opened after a delay of time T2, loop
P-5: the relay opens after a delay of time T1, then closes after a delay of time T2 and reactivates

Typical application: first, let the relay open with a 4.05 second delay, then close after a 10 minute delay and finish

First set the time, T1=4.05 T2=0.1.0 Second set the working mode P-3, it will automatically memorize 5s after setting, and start working.
2. If it is necessary to stop during operation, press the stop button to stop the relay and reset the data. Press the stop button again to activate again. Short press the setting button, the digital tube flashes, at this time, press the button to increase or decrease to set T2, 5 seconds after the completion of the setting, automatic memory starts to work. Time range: Automatically change the range. The default interval is seconds. Decrease the number to 0, keep pressing the button to decrease, the interval will automatically change to 99.9s; add the number to 999, keep pressing the button to increase, the range will automatically change to 0.0.0 Long press the setting key to enter P-0 parameter, and set the required working mode by pressing the plus or minus key on the current interface.
2. If it is necessary to stop during operation, press the stop button to stop the relay and reset the data. Press the stop button again to activate again. Short press the setting button, the digital tube flashes, at this time, press the button to increase or decrease to set T2, 5 seconds after the completion of the setting, automatic memory starts to work. Time range: Automatically change the range. The default interval is seconds. Decrease the number to 0, keep pressing the button to decrease, the interval will automatically change to 99.9s; add the number to 999, keep pressing the button to increase, the range will automatically change to 0.0.0 Long press the setting key to enter P-0 parameter, and set the required working mode by pressing the plus or minus key on the current interface.