Fluke 115C field technician’s digital multimeter measures True-rms voltage and current with plus resistance, continuity and capacitance to meet the needs of a wide variety of field service technicians.
The 115C digital multimeter offers the users one-handed operation and a backlit display. The large, easy-to-read digits offer a 6000-count resolution. The 115C provides Min/Max/Average with elapsed time to record signal fluctuations. It also measures:
AC and DC voltage to 600V,
AC and DC current to 10 A (20 A overload
for 30-seconds max).
Fluke 117C: Compact digital multimeter
designed for electricians
The Fluke 117C Electricians Multimeter is a
compact, CAT III 600 V, True-rms meter that includes an easy-to-use interface
with a bright backlight for darker worksites. It saves you time and enables you
to move from job to job more quickly. With a quick turn of the dial you can get
measurements for:
Resistance
Continuity
Frequency
Capacitance
Min/Max/Average
Model |
Fluke 115C |
Fluke117C |
||
Specifications |
||||
Maximum voltage between any terminal and
earth ground |
600v |
|||
Frequency, non-contact |
115C N/A |
117C ✔ |
||
Safety |
IEC 61010-1: Pollution Degree 2, |
|||
Fuse for A input |
11 A, 1000 V FAST Fuse (Fluke PN 803293) |
|||
Display |
Digital: 6,000 counts, updates 4 per
second |
|||
Bar graph |
33 segments, updates 32 per second |
|||
Operating temperature |
-10°C to +50°C |
|||
Storage temperature |
-40℃ to + 60℃ |
|||
Battery type |
9 volt Alkaline, IEC 6LR61400 hours
typical, without backlight |
|||
Accuracy Specifications |
||||
DC millivolts |
Range/resolution |
600.0 mV / 0.1 mV |
||
Accuracy |
±([% of reading] + [counts]): 0.5% + 2 |
|||
DC volts |
Range/resolution |
6.000 V / 0.001 V |
||
Accuracy |
±([% of reading] + [counts]): 0.5% + 2 |
|||
Auto volts |
115C N/A |
Range/resolution |
600.0 V / 0.1 V |
|
Accuracy |
2.0% + 3 (DC, 45 Hz to 500 Hz) |
|||
AC millivolts¹ True RMS |
Range/resolution |
600.0 mV / 0.1 mV |
||
Accuracy |
1.0% + 3 (DC, 45 Hz to 500 Hz) |
|||
AC volts¹ True RMS |
Range/resolution |
6.000 V / 0.001 V |
||
Accuracy |
1.0% + 3 (DC, 45 Hz to 500 Hz) |
|||
Continuity |
Range/resolution |
600 Ω / 1 Ω |
||
Accuracy |
Beeper on < 20 Ω, off > 250 Ω
detects opens or shorts of |
|||
Ohms |
Range/resolution |
600.0 Ω / 0.1 Ω |
||
Accuracy |
0.9% + 1 |
|||
Range/resolution |
40.00 MΩ / 0.01 MΩ |
|||
Accuracy |
5% + 2 |
|||
Diode test |
Range/resolution |
2.00 V / 0.001 V |
||
Accuracy |
0.9% + 2 |
|||
Capacitance |
Range/resolution |
1000 nF / 1 nF |
||
Accuracy |
1.9% + 2 |
|||
Range/resolution |
> 1000 μF |
|||
Accuracy |
5% + 20% |
|||
Lo-Z capacitance |
Range |
1 nF to 500 μF |
||
Accuracy |
10% + 2 typical |
|||
AC amps True RMS (45 Hz to 500 Hz) |
Range/resolution |
6.000 A / 0.001 A |
||
Accuracy |
1.5% + 3 |
|||
DC amps |
Range/resolution |
6.000 A / 0.001 A 10.00 A /
0.01 A |
||
Accuracy |
1.0% + 3 |
|||
Hz (V or A input)² |
Range/resolution |
99.99 Hz / 0.01 Hz |
||
Accuracy |
0.1% + 2 |
|||
Mechanical and General Specifications |
||||
Size |
167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in) |
|||
Weight |
550 g |