MS9540 OPERATIONAL |
|
Light Source |
Visible Laser Diode 650 nm ± 10 nm |
Laser Power |
0.7 mW (peak ) |
Depth of Scan Field
|
0 mm - 203 mm (0” - 8”) for 0.330 mm (13 mil) bar code (see drawing below) at default setting |
Width of Scan Field |
64.0 mm (2.5”) @ face; 249 mm (9.8”) @ 203 mm (8.0”) (see drawing below) |
Scan Speed |
72 ± 2 scan lines per second |
Scan Pattern |
Single scan line |
Minimum Bar Width |
0.132 mm (5.2 mi ) |
InfraRed Activation |
Long Range: 0 mm - 279 mm ± 51 mm (0" - 11" ± 2") Short Range: 0 mm - 102 mm ± 25 mm (0" - 4" ± 1") |
Decode Capability |
Auto discriminates all standard bar codes; for other symbologies call Metrologic |
System Interfaces |
USB |
Print Contrast |
35% minimum reflectance difference |
Roll, Pitch, Yaw |
42°, 68°, 52° or 360°, 60°, 60° |
Beeper Operation |
7 tones or no beep |
Number Characters Read |
Up to 80 data characters (maximum will vary based on symbology and density) |
Indicators (LED) |
Red = Good read / Green = Laser on, ready to scan / Yellow = CodeGate active (off); auto-trigger mode (on) |
|
MS 9540 MECHANICAL |
|
Length Width |
198 mm (7.8") (see drawing below) 45 mm (1.8"); at handle / 78 mm (3.1"); at head |
Depth |
40 mm (1.6") |
Weight |
149 g (5.25 oz) |
Cable |
Standard 2.1 m |
|
MS9540 ELECTRICAL |
|
Input Voltage |
5 VDC ± 0.25 V |
Power Operating Power Standby |
825 mW 600 mW |
Current Operating Current Standby |
165 mA typical @ 5VDC 120 mA typical @ 5VDC |
DC Transformers |
Class 2; 5.2 VDC @ 650mA |
Laser Class |
CDRH: Class II; EN60825-1:1994/A11:1996 Class 1 |
EMC |
FCC Class B |
|
MS 9540 ENVIRONMENTAL |
|
Operating Temperature |
0°C to 40°C (32°F to 104°F) |
Storage Temperature |
-40°C to 60°C (-40°F to 140°F) |
Humidity |
5% to 95% relative humidity, non-condensing |
Light Levels |
Up to 4842 Lux (450 footcandles) |
Shock |
Designed to withstand 1.5 m (5') drops |
Contaminants |
Sealed to resist airborne particulate contaminants |
Ventilation |
None required |