WHAT YOU WILL RECEIVE

         ONE (1) NEW AQUATEC 6800 SERIES RO BOOSTER PUMP WITH 1/4" JG INSERTS

PART NUMBER 6840-2J03-B221

INPUT/OUTPUT 1/4" QUICK CONNECT

24 VAC

ONE (1) NEW 6800 TRANSFORMER 115V

PART NUMBER: TAS 114-19EP

MADE IN THE USA

       CLICK BELOW FOR YOUR WARRANTY AND INSTALLATION INSTRUCTIONS

(requires Adobe Reader: it's free)

 

Get It Fast!! Get a Tracking Number!!

For Only $27.00 More, Select USPS Priority Mail at Checkout and Receive Your Item in 2-3 Days and Get a Tracking Number and Up to $50 Insurance Protection.

NOTE: USPS does not offer tracking numbers for First Class shipping.

WARNING: Domestic USPS packages are not insured unless Priority Mail or Express shipping are purchased.


Don’t pay more for less!

We ship sooner, faster, and for less than our competitors.

We ship immediately.

We charge you less than our competitors charge you for slower service.

We combine shipping upon request.

We will match all verified competitor's prices.

We ship internationally.

Service makes the difference!

BETTER PUMPS BETTER LIVING


PUMP


TYPICAL APPLICATIONS

 

Water Treatment/RO

Carbonation Systems

Misting Systems

Alternative Energy/Solar

Medical Labwater

Laser Cooling Systems

Fuel Cells



               USE AND BENEFITS

This pump is usually used to boost water supply pressure to a Reverse Osmosis water system.

If your water supply pressure is below 40psi, you should add this pump to your RO system.

This water booster pump is to boost the input water pressure.  It is usually used to increase the input water pressure for Reverse Osmosis systems. (boost pressure to 60 to 80 psi).

This pump is suitable for RO systems rated up to 50GPD membrane.

For RO systems, an increase in input pressure means an increase in water production and water purity

RO systems will run more efficient, with less waste water. Since it uses a pressure switch and solenoid valve to turn on/off the water input, it can turn on and turn off more accurately than the mechanical auto shut-off valve.

For large water containers or an open water tank, you can use a float switch or level switch to control the operation of the pump.


Product Data Sheet: Aquatec.com

Warranty Statement: Aquatec.com

Installation Instructions: Aquatec.com


Aquatec's original product, and still the "global standard" in booster pump technology, providing reliable inlet pressure for efficient membrane utilization.

These pumps are capable of continuous duty and are effective for recirculation based applications as well. 

                    

They are ideally suited to work with hydro-pneumatic storage systems but are compatible with most hydraulic shut-off valves also.


These pumps are commonly used with one or more of Aquatec's flow control components including: 

pressure switches (PSW Series), tank level controllers (TLC Series) or electronic shut-off valves (ESO Series).


FAQ for RO BOOST PUMPS and DELIVERY PUMPS:

Q. The R.O. system is not working properly

A. See IMI 147, R.O. Boost Pump Troubleshooting guide: Aquatec.com

Q. The CDP, Continuous Duty Pump, runs continuously. 

A. See IMI 156, Automatic Shut Off Valve’s effect on the PSW’s shut off ability

Q. The pump that delivers water from the holding tank to the refrigerator is noisy

A. The pressure switch controlled demand delivery pump is probably delivering more

water than the icemaker can accept (usually about 1/4 gpm at 35 psi), and is momentarily

reaching its shutoff pressure. Use a lower flow pump, and add an accumulator between

the pump and refrigerator if necessary. Open the “high voltage drinking water delivery

pumps” selection chart, section A, for recommended choices. 

Q. What effect does feed pressure have on the tank/faucet pressures?

A. None. The flow of water to the membrane will increase, but 80 psi pump discharge

pressure will not change due to the preset by pass pressure.

Q. What effect does higher by-pass pressures have on tank/faucet pressures?

A.  Since the pressure entering the membrane has increased, so will the pressure exiting

the membrane, at the expense of flow, however. 

Q. What is the membrane rating based on?

A. Based on 95% rejection of TDS levels at 600 ppm and 60 psi membrane feed pressure,

in a 70 degree F ambient environment. 

Q. The boost pump output pressure is only 60psi?

A. Assuming you have not adjusted the by pass setting, you may be using a membrane

with a permeate production higher than the pump can supply. Either switch to a higher

flow pump, or go to a lower rated membrane. 

Q. Are low feed pressure shut off switches (LPS) available?

A. The LPS comes with the appropriate wire harness, but a tee with a 1/8” NPT female

center port is not provided. 


TRANSFORMER


Aquatec’s transformers are both current and temperature protected for additional safety protection. Aquatec pump-transformer combinations are designed to operate at maximum efficiency under a wide range of voltage conditions without overheating or overloading. This can save the end-user thousands of kilowatt hours per year compared to less efficient pumps.

 

Features

New Aquatec replacement tranformer for 6800 series booster pumps

Designed and manufactured by Aquatec to ensure compatibility and proper operation

Standard 2-Prong Plug

OEM Part

Specifications

Input Voltage: 116-120 VAC

Output Voltage Max: 24 VAC

Cord Length: 6 Feet

Overload Protection: Circuit Breaker, Auto-Reset


Specification Sheet: Aquatec.com


MyStoreMaps

Add a map to your own listings. FREE Trial !