High precision AD584L voltage reference module reference voltage source



AD584 eight pins is a precision reference voltage source, provides programmable four common output voltage: 10.000 V, 7.500 V, 5.000 V and 5.000 V. The input voltage range of 4.5 V to 30 V. This device adopts the technology of the laser wafer to adjust the output level of programming to adjust the pin and the temperature coefficient, thereby gaining the most flexible single chip, high precision reference voltage source. AD584 recommended used for outside precision reference voltage source 12 or 14 d/a (DAC)/module reference voltage source converter (ADC), its performance is superior to the standard usually detached benchmark voltage source.




Circuit board features:
1. 15 v onboard battery, we know that the noise of the battery is the lowest, enable it to pure static, stable output voltage provide reliable guarantee,
2. The board has four programming terminal, each terminal corresponding to an output voltage, short circuit by short circuit blocks corresponding terminal can have the corresponding voltage. Because AD584 programming pin when programming the short circuit resistance can affect the output voltage, in order to reduce short circuit resistance, use two terminals in parallel. With the benefits of the alternative switch terminal is more reliable and flexible, short circuit resistance can be smaller.
3. The temperature coefficient of 5 PPM / ° C (maximum, 0 ° C to 70 ° C, AD584L) 15 PPM / ° C (maximum, and 55 ° C to + 125 ° C, AD584T)
4. The power consumption, static current: 1 mA (maximum), low static current is very suitable for batteries.
5. Load capacity: 10 mA
6. Working voltage: 4.5 V to 30 V, attention, working voltage required is higher than the output voltage.
7. The temperature range: AD584J/K/L the rated operating temperature range of 0 ° C to + 70 ° C, AD584S/T is 55 ° C to + 125 ° C.
8. With an external power supply interface, need more than 11 v dc voltage.
9. Reference voltage output interface using pure copper 2 mm test, persons possessing the multimeter measure pen or other instrument calibration, etc.
10. Each board before leaving the factory with a Aglient six and a half multimeter for testing, and the output voltage, the convenient user use.
11. A multimeter and the board before testing warmed up at least 30 minutes at room temperature is 25 degrees, guarantees the detection accuracy.
 


Here are six and a half multimeter measured 2.5 V voltage output effect, 2.49978 V and the standard error is very small. 




Shipping list: 1pcs x reference voltage module (does not include the battery) 



DataCaciques