This series controller is specialized for Diesel / Gasoline / Gas Genset Start, Stop, Parameters monitoring, faults-checking as well as data setting.
4.3 inch colorful LCD screen display with brand new UI design is adapted in this controller that the relative failures can be displayed directly. All the parameters can be displayed by simulated indicators and words. Besides, LCD screen can display various faults in the same time that the genset will be stopped once it can not work smoothly.
There are Chinese/English Language interface options. All the parameters can be configured through the front face buttons or use programmable interface by RS485 or USB to adjust via PC. It can be widely applied for all kinds of auto control system of gensets.
Features:
There are four Models under DC7xD series.
DC70D: used for single machine automation. Start/Stop through remote start signal.
DC72D:Based on DC70D, it adds Mains monitoring and AMF (Mains/Generator automatic switching control ) , especially suitable for the automation system composed by mains and genset.
DC70DR: Based on DC70D, it adds Rs485 port.
DC72DR: Based on DC72D, it adds Rs485 port.
Main Features:
- 32 units Micro-procession technology is used.
- 4.3 inch TFT colorful big screen LCD, option language interface(Chinese/English), user’s language set if necessary.
- Indicator and number display through UI surface.
- Acrylic material is adapted to protect the screen.
- Silicone panels;
- USB Port: parameters can be set even without power through USB port to monitor in real time.
- With RS485 communication port, can achieve “Three Remote” functions via MODBUS protocol.
- CAN communication port, J1939 protocol inside.
- Various kinds of parameters display.
- Input/output function, status can be shown directly.
- More categories of surface setting.
- Real time clock inside: preset time operate and auto maintenance is available. Genset working plan can be set as per week or month.
- Three class protection countdown function, which can set the maintenance time or date.
- Records function: relative faults shall be recorded in real time.
- Totally 7 relay’s output, among which 5 relay output can be self-configurable, each relay can be set as max 50 functions, besides, there are 4 groups as non-contact terminals.
- 5 relays can be set as switch value input, and each can be set as max 40 functions.
- 4 sensor simulation input connectors, 6 input types is configurable and various kinds of units can be set.
- Battery charging control function, which can protect the battery according to battery voltage status.
- Sensor can be self-defined by front face button or PC software.
- Adapt to 3P4W,1P2W,2P3W(120V/240V,50/60HZ)
- Various of crank conditions(RPM, Frequency, Oil Pressure) can be chosen
- Control Protection: Auto Start/Stop of genset, load transfer (ATS control) and perfect failure display and protection.
- Standard water-proof rubber gasket. The waterproof can reach IP54
- Module design: All the connections are adapted with European connectors so that installation, connection, repair and replacement can be more easily.
Parameters Display
- Engine RPM
- Engine oil pressure
- Engine water temperature
- Engine fuel temperature
- Engine cylinder temperature
- Engine Tank temperature
- Engine fuel level
- Engine battery voltage
- charging voltage
- Mains Frequency (only for DC72D)
- Mains phase voltage L-N (only for DC72D)
- Mains phase voltage L-L (only for DC72D)
- Generator 3 Phase voltage L-N
- Generator 3 Phase voltage L-L
- Generator 3 phase current A
- Generator Frequency Hz
- Generator Power Factor COSφ
- Generator active power KW
- Generator apparent power KVA
- Generator reactive power KVar
- Current loading rate %
- Total average loading rate %
- Current consumption KWH
- Total consumption Kwh
- Total Crank times
- Current running time
- Total running time
- Three classes maintenance notice
Protection
- over speed
- under speed
- Low oil pressure
- High water temperature
- High Oil temperature
- High Cylinder Temperature
- High Tank temperature
- Low fuel level
- Low oil level
- External emergency alarm
- D+ Opened
- RPM Lost
- Sensor Open
- Over Frequency
- Under Frequency
- Over voltage
- under voltage
- over current
- Non-balance of current
- Over power
- Lack of Phase
- reverse phase sequence
- Gen load failure
- Gen unload failure
- Mains Load failure
- Mains unload failure
- Primary maintenance expire
- Secondary maintenance expire
- Third maintenance expire
- ECU alarm failure
- ECU communication Failure
- Low water level alarm
- Emergency Stop
- Crank failure
- Over battery voltage
- Under Battery voltage
- Charging failure
- Battery Charging failure
- Stop Failure
Parameters
Options |
Parameters |
Working voltage |
DC8V----36V Continuous |
Power consumption |
Standby:24V:MAX 1W |
Working:24V:MAX 5W |
|
AC Voltage Input |
1P2W 20VAC-276VAC(ph-N) |
2P3W 20VAC-276VAC(ph-N) |
|
3P4W 20VAC-276VAC(ph-N) |
|
Rotate speed sensor Frequency |
150-9000Hz |
MAX Accumulating Time |
99999.9Hours(Min Store time:6min) |
Fuel Relay Output |
16Amp DC+VE Supply voltage |
Start Relay Output |
16Amp DC+VE Supply voltage |
Programmable Relay output 1 |
5Amp DC+VE Supply voltage |
Programmable Relay output 2 |
5AMP Non-contact-Normal open--Normal close output |
Programmable Relay output 3 |
5AMP Non-contact Normal Open output |
Programmable Relay output 4 |
5AMP Non-contact normal open output |
Programmable Relay output 5 |
5AMP Non-contact-Normal open--Normal close output |
Excitation output |
Max 1AMP DC+VE supply voltage |
Switch value input |
Available if connecting with Battery - |
Working condition |
-20-65℃ |
Storage condition |
-40-85℃ |
Protection Level |
IP54:when waterproof rubber gasket is added between controller and its panel |
Overall dimension |
210mm*160mm*50mm |
Panel cutout |
186mm*142mm |
Package
1 x Multi-functional meter (the sensor not included)
Remark
Note: The instruction will share a link for reference when purchased this meter
It’s not enclosed in the package.
- We Ship to Worldwide.
- Items will be shipped within 1-2 business days on payment
received.
- Items are shipped from Hong
Kong Post
Airmail, reach most of the countries within 10 to 20
business days.
- Delivery time depends on
destination, it may takes up to 20 business days.
Country |
Estimated
Delivery Time |
||||||
Working Days
(not including holiday) |
5-7 |
8-11 |
12-14 |
15-19 |
20.22 |
>22 |
|
Working Days
+ Saturday + Sunday |
5-9 |
10-15 |
16-20 |
21-25 |
26-30 |
>31 |
|
United States |
Rate (item
arrived) |
5 .2% |
50.1% |
29.6% |
10.5% |
4.5% |
0.1% |
United
Kingdom |
Rate (item
arrived) |
9.9% |
63.2% |
19.1% |
3.4% |
4.3% |
0.1% |
Australia |
Rate (item
arrived) |
21.4% |
50.2% |
14.2% |
7.2% |
7.1% |
0.1% |
France |
Rate (item
arrived) |
10.5% |
28.6% |
43.8% |
10.1% |
7.0% |
0.1% |
Germany |
Rate (item
arrived) |
11.1% |
22.2% |
30.3% |
20.8% |
15.1% |
0.1% |
Canada |
Rate (item
arrived) |
0.0% |
47.2% |
31.4% |
17.6% |
3.8% |
0.1% |
Spain |
Rate (item
arrived) |
3.5% |
25.0% |
47.9% |
12.9% |
10.6% |
0.1% |
India
/ Italy / Russian Federation / Region of Africa and South
America …etc |
Weeks (item arrived) |
4-6 Weeks |
Items within 30days returns guarantee. Prior to any return please get in touch with us via eBay message.
Due to the nature of electronic goods, a very small number of items can be faulty. If there is any defected goods, please contact us to resolve any issues before leaving negative feedback or low rating. We will gladly replace or refund.
We stand behind our
products that can provide with professional and secure packaging. You can also
be assured that the service will continue after you receive you purchase. Our
goal is for you to return to our store or recommend us. So we wish for you to
only to have a positive experience.
·All the
eBay messages and emails will be answered within 24 hours.
·If you do
not receive our reply, please kindly re-sent your email and we will reply to
you as soon as possible.
·Excellent
Feedback
·PayPal
verified
·Professional
customer service
·All
questions answered within 24 hours during business hours