Brief Introduction |
Dynamic ECG Systems adopt 12-lead system of international standard, which can continuously record ECG waveform for 24-hour and analyze ECG waveform by the PC software. It is applicable for use in medical institution and community.
Function
1)The recorder can real-time store ECG data for 24-hour.
2)Arrhythmia
analysis basing on MCSSTM and TMCATM can greatly reduce doctor’s work.
3)Sync
analysis for 12-lead, which ensures that QRS waveform can be found accurately,
and no distortion.
4)With more than 10 templates(such as atrial premature
beat, ventricular premature beat, long interval, atrial fibrillation, etc.) and
many user-defined modules, which can almost distinguish any kind of pathologic
waveforms.
5)Flexible analysis channel selection function, which ensures that
any channels can be selected as the main analysis channel.
6)Flexible atrial
fibrillation analysis, which ensures that physicians can use the whole or
segmented AUTO/manual analysis, more accurate in atrial fibrillation
analysis.
7)All pacemakers(such as AAI, VVI, DDD etc.) can be analyzed by the
powerful pacemaker analysis function.
8)With many pacing analysis templates,
such as “Dual chamber pacing”, “Atrial pacing”, “Ventricular pacing”,
“Ventricular Pseudofusion” and “Ventricular asynchronous pacing”,
etc.
9)Single or full-lead ECG in any time bucket can be reviewed by the fast
review analysis function.
10)With analysis functions for 5-minute, 1-hour and
24-hour heart rate variability.
11)One-key print, convenient and fast to
print the reports.
12)Perfect case management function.
13)Abnormal ST can
be analyzed according to the whole and event by the advanced ST segment analysis
and total load of myocardial ischemia, which can help the doctors
comprehensively judge myocardial ischemia.
14)The risk of sleep breath pause
can be predicted by the unique "Sleep breath pause syndrome"analysis
function.
15)The death risk in patients with myocardial infarction can be
predicted by the "HRT" analysis function.
16)“T-Wave alternation” is an
important index to predict the malignant arrhythmia and sudden cardiac
death.
17)With QTD(QT dispersion), VCG(vector cardiogram), VLP(ventricular
late potential) and TVCG(time vector cardiogram) analysis modules, more valuable
in analysis report.
Performance
Lead: standard 12-lead
Record time: 24-hour
Power supply: two “AA”
batteries
Interface: USB2.0
Calibration voltage: 1mV±5%
Noise level:
≤30μV
CMRR: ≥60dB
Low-frequency characteristics: time
constant≥3.2s
Scan speed: 25mm/s±5%
Polarizing voltage: ±300mV,
sensitivity: ≤±10%
Minimum measure signal: 50 µV p-p
Accessories
Lead cable (1 set)
ECG electrode (1 bag)
USB
cable(1)
Disk(1)
Bag(1)
User manual(1)
Physical characteristic
Dimension: 111mm(L) × 60mm(W) × 25mm(H)
Weight: about 105g(without
batteries)
Buy Safe Product!
The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE:
The
sale of this item may be subject to regulation by the U.S. Food and
Drug Administration and state and local regulatory agencies. If the item
is subject to FDA regulation, We will verify your status as an
authorized purchaser of this item before shipping of the item.