Model:ECG1200G

               
Ship from Illinois,united states. 2-5 days arrival.Offer High quality service and tow years warranty

Tips:

USA  Buyer:  ship from USA warehouse . Fast delivery (2-5 days) ;

Other Buyer : ship from China Warehouse. 1-2 weeks delivery.

CONTEC ECG1200G Digital ECG/EKG Machine 12 Channel Electrocardiograph PC Software

Touch Screen 
Tips:

USA  Buyer:  ship from USA warehouse . Fast delivery (2-5 days) ;

Other Buyer : ship from China Warehouse. 1-2 weeks delivery.
               
Introduction 

ECG1200G is an electrocardiograph which can collect 12-lead ECG signal simultaneously and print ECG waveform with thermal printing system. It features in, recording and displaying ECG waveform in AUTO/Manual mode, measuring and diagnosing ECG waveform parameters automatically, prompting for “Lead off” and “Lack of paper”, multi-language interface, AC/DC, selecting rhythm lead, printing the trend chart and histogram of P-R interval, case database management.

Function 

1)Sync collection for 12-lead ECG, adopt digital signal processing technology and get high-quality ECG waveform via power frequency filter, baseline filter and EMG filter of ECG signal.
2)Display of 3/6/12-lead ECG, print mode, sensitivity, paper speed and filter state, etc. on one screen, convenient for contrastively diagnosing.
3)Multiply printing modes and formats, including auto 12x1, auto 6x2+1, auto 6x2+1_H, auto 6x2, auto 6x2_H, auto 3x4+1, auto 3x4+2, rhythm 12, rhythm 10, rhythm 8, rhythm 6, manual, etc. Trend chart and histogram of P-R interval can be printed, waveform length printed can be adjusted, and with time print function, which meets different requirements.
4)Paper speed: 5mm/s, 6.25mm/s, 10mm/s, 12.5mm/s, 25mm/s, 50mm/s.
5)With the functions of auto-analysis and auto-diagnosis for routine ECG parameters, provide measurement results and auto-diagnosis conclusion for HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1), etc. which reduces the doctor’s burden.
6)Built-in memory stores up to 1000 cases, convenient for case review and statistic.
7)Multi-language(Turkish, French, Chinese, English, German, Kazakstan, Polish, Portuguese, Russian, Slovenian, Spanish and Ukrainian) interface and report.
8)In optimal DC state, up to 10-hour standby time, continuous print more than 3-hour, record up to 300 ECG waveform(commonly, it is 3s case), which meets the requirements of visiting a patient at home and body examination.

Performance

Input mode: floating and defibrillation protection
Frequency response: 0.05Hz ~ 150Hz(-3dB~+0.4dB)
CMRR: >60dB, >100dB(add filter)
Time constant:≥ 3.2s
Patient leak current: <10µA
Calibration voltage: 1mV
Sensitivity: 2.5, 5, 10, 20, 40 mm/mV ±5%, standard sensitivity: 10mm/mV±2%
Noise level: ≤15µVp-p
Input circuit current: ≤50nA
Input impedance: ≥50MΩ
Sampling accuracy: 12-bit
Safety classification: class I, type CF and defibrillation-proof applied part
Recording mode: thermal printing system
Paper size: 210mm(W)×20m(L)
Sampling frequency: 1000Hz
EMG interference filter: 25Hz/35Hz (-3dB)
Power frequency filter: AC 50Hz/60Hz(-20dB)
Paper speed: 
Auto: 25, 50mm/s, ±5%
Rhythm: 25, 50mm/s, ±5%
Manual: 5, 6.25, 10, 12.5, 25, 50mm/s, ±5%
Auto record: set record according to auto record format and mode, automatically switching leads, measuring and analyzing.
Rhythm record: set record according to rhythm record format and mode, automatically measuring and analyzing.
Manual record: set record according to record format, manually switching leads.
Measurement parameters: HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1)
Power supply: 
AC: 100V~240V(50/60Hz)
DC: 14.8V/3500mAh rechargeable lithium battery
Fuse specification: two AC time lag fuse(φ5×20mm), T1.6AL250V
Waterproof degree: IPX0
Working mode: continuous working

Accessories

Standard:
A lead cable
A limb electrode
A chest electrode
A thermal recording paper
A power cord
An earth wire
A user manual 


Physical characteristic

Working environment
Temperature: 5℃~40℃
Relative humidity: 25%~95%(non-condensing)
Atmospheric pressure: 700hPa~1060hPa
Transport and storage environment
Temperature: -40℃~+55℃
Relative humidity: ≤95%
Atmospheric pressure: 500hPa~1060hPa
Dimension: 340mm(L) × 320mm(W) × 85mm(H)
Weigh: 3.2Kg

Buy safe products

The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE: The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If the item is subject to FDA regulation, we will verify your status as an authorized purchaser of this item before shipping of the item.

The Fingertip Pulse Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG)with the code 197923, and certified by FDA of United States and CE,TUV of Europe. The  Fingertip Pulse Oximeter that is FDA 510K Approved

               

Thanks for your purchase! 
  

Powered by SoldEazy


Only English User Manual,Please contact us if you need other language version.thank you
ibay365