Specification
Specifications |
Delta Inverters VFD-L
Series |
Delta Inverters VFD-L
Series |
||||
Voltage Class |
115V |
230V |
||||
Model Number VFD- L
A/B |
004 |
002 |
004 |
007 |
015 |
|
Applicable Motor Output
(kW) |
0.4 |
0.2 |
0.4 |
0.7 |
1.5 |
|
Rated Output Capacity
(KVA) |
0.6 |
1.0 |
0.6 |
1.0 |
1.6 |
2.7 |
Rated Output Current (A) |
1.6 |
2.5 |
1.6 |
2.5 |
4.2 |
7.0 |
Max. Output Voltage (V) |
3-phase corresponds to
double input voltage |
Three-phase
corresponds to input voltage |
||||
Rated Frequency (Hz) |
1.0~400Hz |
|||||
Rated Input Current (A) |
6 |
9 |
4.9/1.9 |
6.5/2.7 |
9.7/5.1 |
*/9 |
Input voltage Tolerance |
Single phase
90~132V 50/60Hz |
Single / 3-phase
180~264V 50/60Hz |
3-phase 180~264V50/60Hz |
|||
Frequency tolerance |
±5% |
|||||
Control system |
SVPWM (Sinusoidal Pulse
Width Modulation, carried frequency 3kHz~10kHz) |
|||||
Output Frequency
Resolution |
0.1Hz |
|||||
Torque Characteristics |
Including the
auto-torque, auto-slip compensation, starting torque can be 150% at 5 Hz |
|||||
Overload Endurance |
150% of rated current for
1 minute |
|||||
Accel/Decel Time |
0.1~600Sec. (can be set
individually) |
|||||
V/F pattern |
V/F pattern adjustable |
|||||
Stall Prevention Level |
20~200%, setting of Rated
Current |
|||||
Frequency Setting Keypad External
Signal |
Setting by ▲▼ keys or V.R Potentiometer-5KW/0.5W, DC 0 ~ +10V (input impedance 47KW), 4~20mA (outputimpedance
250W), multi-function inputs1 to 3 (3steps, JOG, UP/DOWN command),
communication setting |
|||||
Operation Setting Keypad |
Setting by RUN//STOP keys |
|||||
Signal External Signal |
M0,M1,M2,M3 can be
combined to offer various modes of operation, RS-485 communication port |
|||||
Multi-function Input
Signal |
Multi-step selection 0 to 3, Jog, accel/decel inhibit, first/second accel/decel switch,
counter, PLC Operation, external Base Block (NC,NO) selection |
|||||
Multi-function Output
Signal |
AC Drive Operating,
Frequency Attained, Non-zero speed, Base Block, Fault Indication,
Local/Remote indication, PLC Operation indication. |
|||||
Other Function |
AVR, S-curve,
Over-Voltage Stall Prevention, DC Braking, Fault Records, Adjustable Carried
Frequency, Starting Frequency Setting of DC Braking ,Over-Current Stall
Prevention, Momentary Power Loss restart, Reverse Inhibition, Frequency
Limits, Parameter Lock/Reset |
|||||
Protection |
Over Voltage, Over
Current, Under Voltage, Overload, Electronic thermal, Overheating,
Self-testing |
|||||
Other |
Including EMI Filter |
|||||
Cooling |
Forced air-cooling |
|||||
Installation Location |
Altitude 1,000 m or
below, keep from corrosive gasses, liquid and dust |
|||||
Ambient Temperature |
-10℃-40℃
(Non-Condensing and not frozen) |
|||||
Storage Temperature |
-20℃
to 60℃ |
|||||
Ambient Humidity |
Below 90%RH
(non-condensing) |
|||||
Vibration |
9.80665m/s2(1G) less than
20Hz, 5.88m/s2 (0.6Gat) 20 to 50Hz |
| ||||||||
| ||||||||
|
Terms & Conditions
l Payment must be received within 7 days after auction closing. We ship every business day
l Some used items may have cosmetic imperfections such as scratches, ink markings, etc., which do not in any way affect the functionality or performance of the unit.
l Products are tested and fully functional before shipping. AS-IS items are not tested and will not be covered under warranty, unless otherwise stated.
l Damage caused by misuse or improper handling by the buyer will not be covered under warranty.
l Any presumed defective units must obtain an RMA # before return.
l Item returned will be tested. If found defective, either a replacement or a refund will be sent immediately. If found not to be defective or damage caused by misuse or improper handling, item will be returned at buyers expense.
l International order will ship via FEDEX or DHL or POSLAJU provide with tracking number and informations together
IFS: 3G