READ CAREFULLY ALL LISTING BEFORE BUYING!!!!!


This listing is for a Brand New, Model QDZY43G, 12V / 24V DC (Air Cooling) Compressor and controller, R600A refrigerant, max. 95w, Refrigerator Fridge Freezer Marine Boat or for Solar Off Grid.

Direct low cost replacement for Danfoss BD35 DC compressors


Suitable for water dispenser, small refrigerator, small freezer, wine cellar and other small cooling appliances used for car, ship and camping.

Electronic controller INCLUDED with purchase of compressor (like on picture)


Electronic controller AVAILABLE as spare parts in my store



Perfect for AC to 12-24DC fridge conversion for most modern Energy-star mini fridges(Like Danby) that works with R600A(Isobutane gas, ozone friendly)

Choose right compressor size and gas, Send me a message if you need help with that!


  • Model NO.: QDZY43G

  • Cooling System: Air Cooling

  • Cylinder Position: Horizontal

  • Compress Level: Single-Stage

  • Displacement: 4.3cm3

  • Application: Lbp, Mbp, Hbp

  • Usage: Vehicle Freezer/Refrigerator

  • Cooling Capacity: 45~78W

  • Lubrication Style: Lubricated

  • Cylinder Arrangement: Single

  • Structure Type: Closed Type

  • Refrigerant Type: Isopropane-Isobutane

  • Power Source: Battery or Solar


ct Performance

 1)QDZY43G, DC series, use R600A refrigerant; 
 2)Voltage application 12V and 24V;
 3)Cooling type: ST or FAN;
 4)Application: Low Back Pressure, Middle Back Pressure;

Suitable for water dispenser, small refrigerator, small freezer, wine cellar and other small cooling appliances used for car, ship and camping.



Refrigerant

Application

Model

Dis.

Speed

23.3 ?

 

 

capacity

COP

Power

cm3

rpm

W

BTU

W/W

R600A

LBP

QDZY43G

4.3

2000

56

133

1.1

12/24V DC

2500

56

191

1.1

3000

67

228

1.1

3500

79

265

1.1

DIMENSIONS:


compressor dimentions scematic


WIRING:

Wiring scematic


Installation(Fig.1)
Connect the terminal plug from the electronic unit to the compressor terminal. Mount the electronic unit
on the compressor by ping the cover over the screw head(1).

Power supply(Fig.1)
The electronic unit must always be connected directly to the battery poles (2). Connect the plus to + and
the minus to -, otherwise the electronic unit
will not work. The electronic unit is protected against reverse battery protection of the
installation, a fuse (3) must be mounted in the + cable as close to the battery as possible. 15A fuse for
12V and 7.5A fuse for 24V circuits are a main switch (4) is used, it should be rated to a
current of min. 20A. The wire dimensions in Table. 2 must be observed. Avoid extra junctions in the
power upply system to prevent voltage drop from affecting the battery protection setting.

Battery protection(Fig.1)
The compressor is stopped and re-started againaccording to the decided voltage limits measured onthe
+ and - terminals of the
electronic unit. The standard settings for 12V and 24V power supply systems
appear from Table. 3. Other settings (Table. 1) are optional if a connection which includes a resistor (9)
is established between terminals C and P.

Thermostat(Fig.1)
The thermostat (7) is connected between the terminals C and T. Without any resistor in the control circuit,
the compressor with electronic unit
will run with a fixed speed of 2,000rpm when the thermostat is
switched on. Other fixed compressor speeds in the range between 2,000 and 3,500 rpm can be obtained
when a resistor (8) is installed to adjust the voltage (v) of the control circuit. Resistor values for various
motor speeds appear from Table. 4.

Fan(optional,Fig.1)
A fan (5) can be connected between the terminals + and F. Connect the plus to + and the minus to F.
Since the output voltage between the terminals + and F is always regulated to 12V,a 12V fan must be
used for both 12V and 24V power supply fan output can supply a continous current of
0.5A avg . A higher current draw is allowed for 2 seconds during start.

LED(optional,Fig.1)
A 10mA light emitting diode(LED)(6) can be connected between the terminals + and D. In case the
electronic unit records an operational error, the diode will flash a number of times. The number of flashes
depends on what kind of operational error was recorded. Each flash will last 1/5 second. After the actual
number of flashes there will be a delay with no flashes, so that the sequence for each error recording is
repeated every 3 minutes


---------------------------------------------------------------------------------------------

I always carefully pack items with care to avoid damage during shipping.


If item is undeliverable because of buyer's wrong, refused, unreclamed or incomplete address. Buyer pays return shipping cost to Seller (Both Original Shipping AND RETURN SHIPPING).

Buyer is reponsible for his import charges and fees if occurs.


Feel free to contact me for any questions!


Thanks